• Title/Summary/Keyword: EUT

Search Result 28, Processing Time 0.029 seconds

Improved Performance Evaluation Method for EUT in Power Frequency Magnetic Field Immunity Test (전원주파수 자계 내성시험의 개선된 EUT 성능평가방법)

  • 정기범;최재훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.796-802
    • /
    • 2003
  • In this paper, an improved EUT(Equipment Under Test) evaluation method using image monitor for power frequency magnetic field immunity test was proposed and development of an automated real time image monitoring program was described. The proposed power frequence magnetic field immunity test detects automatically the change between the affected and unaffected image of EUT under the influence of electromagnetic wave. The proposed method for real time decision supplements shortcomings of the currently used method which is subjective to tester´s decision by ensuring the repeatability of the test. The change detection of EUT image provides a possibility of the immunity decision for PC monitors. In addition, the method to draw quantitative value in EUT immunity decision is suggested in accordance with the international standards and domestic trends.

Realization of the Image Recognition Algorithm for Automatic Decision of EUT Malfunction (EUT 오동작 판정 자동화를 위한 영상인식 알고리즘의 구현)

  • Yun, Kee-Bang;Lee, Chang-Bok;Ryu, Jae-Chun;Kim, Ki-Doo
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.9-16
    • /
    • 1999
  • We suggest the image recognition algorithm for automatic decision of EUT malfunction using computer vision in the radiant electromagnetic field. We monitor and analyze the EUT malfunction through the numerical value change of electro-measurement and medical instruments, or the image distortion of PC monitor. We could decide EUT malfunction by comparing the object image in the electromagnetic field with the reference image or by recognizing the numerical value change on the video camera monitor. We can show the evidence of EUT malfunction decision and reduce the possibility of malfunction in the tolerance test.

  • PDF

Design of EUT test equipment for EMC Testing (EMC 시험을 위한 EUT 시험장비 설계)

  • Hong-Rak Kim;Youn-Jin Kim;Seong-Ho Park;Man-Hee Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.35-40
    • /
    • 2023
  • For the EMC test, the radiation characteristics and immunity characteristics of the EUT are measured under the condition that the EUT maintains its normal operation. For normal operation of the EUT, it is necessary to operate the EUT and monitor its status through separate equipment outside the anechoic chamber. External equipment operates and monitors the EUT through various communications such as 1553B communication, RS-485 communication, and Ethernet communication. At this time, external equipment can transmit noise through the communication line. This noise is transmitted to the LISN through the connected power cable and measured. It is also radiated through the connection terminal to the LISN. In this case, the communication line is the power line It should be designed so that noise is not transmitted through electromagnetic isolation as much as possible. In addition, noise from external equipment must be suppressed as much as possible from entering the chamber through the communication line. In this paper, external EUT test equipment applied for EMC test It explains the considerations in the design and manufacture of the design and explains the satisfaction of the design through tests including CE and RE.

A Study on the EMS Analysis of Image Variations for EUT (EUT의 영상변화에 의한 EMS 해석에 관한 연구)

  • Yun, Ki-Bang;Lee, Chang-Bok;Jung, Ki-Beom;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.2
    • /
    • pp.76-83
    • /
    • 2002
  • In this paper, we developed the real-time automation program for the immunity test according to the determination of the EUT image, and analyzed the image of standard PC monitor and the monitor image affected by the electromagnetic field. The image change detection algorithm was realized for the real-time determination of the malfunction, and we attempted to obtain the consistent results for the electromagnetic immunity measurement. We showed the possibility to determine the immunity of the PC monitor and other equipment by performing the image change detection of EUT, and the experimental results for the EUT immunity determination of EMS (Electro-Magnetic Susceptibility, IEC 61000-4-3) are also proposed in line with the international standard and domestic trends. 

An effect of length between the EUT and surge generator in surge immunity test (EUT와 서지 발생기 사이의 거리가 서지 내성 시험에 미치는 영향)

  • 이주광;임순재
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.57-61
    • /
    • 1995
  • This paper reports on a theoretical and experimental study on an effect of length between the EUT and surge generator. In the case of using 40m line, surge energy was decreased to 77% of the output of surge generator.

  • PDF

A Study of Test Method for Position Reporting Accuracy of Airborne Camera (항공기 탑재용 카메라 위치출력오차 측정방안 연구)

  • Song, Dae-Buem;Yoon, Yong-Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.646-652
    • /
    • 2013
  • PRA(Position Reporting Accuracy) for EO/IR(Electro-Optic/Infrared) airborne camera is an important factor in geo-pointing accuracy. Generally, rate table is used to measure PRA of gimbal actuated camera like EO/IR. However, it is not always possible to fix an EUT(Equipment for Under Test) to rate table due to capacity limit of the table on the size and weight of the object(EUT). Our EO/IR is too big and heavy to emplace on it. Therefore, we propose a new verification method of PRA for airborne camera and assess the validity of our proposition. In this method we use collimator, angle measuring instrument, 6 dof motion simulator, optical surface plate, leveling laser, inclinometer and poster(for alignment).

Limits of Fully Anechoic Room for Radiated Disturbance Using Correlation Factor (야외시험장과 전자파 완전 무반사실과의 상관계수를 이용한 완전 무반사실의 허용 기준 제안)

  • Lee, Soon-Yong;Chung, Yeon-Choon;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1401-1411
    • /
    • 2010
  • In this paper, we suggested the tolerance limits of FAR(Fully Anechoic Room) using correlation factor between OATS(Open area Test Site) to measure EMI(Electromagnetic Interference) and FAR to measure EMS(Electromagnetic Susceptibility). FAR Project(SMT4-CT96-2133), CISPR/A/665/DTR, and CISPR A/665/DTR documents are analyzed and theoretical correlation factor based on the documents and theoretical equations is drawn. To obtain the experimental correlation factor, EUT(Equipment Under Test) is fabricated as well as measured at the 10 m distance OATS and in the 3 m distance FAR. Also, to suggest the tolerance limits of EUT with multi sources, radiation theory for electric and magnetic dipoles is programmed. We drew the correlation factor for EUT with multi sources through the programs. As the tolerance limits of FAR is newly defined, It can be used alternative test site for OATS to measure EMI, efficiently.

Study on the Radiation Pattern of Radiated Emission above 1 GHz (1 GHz 이상에서의 복사 방출 방사 패턴에 관한 연구)

  • Chung, Yeon-Choon;Lee, Soon-Yong;Kwun, Suk-Tai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.336-344
    • /
    • 2011
  • The purpose of this study is to analyze the radiation-pattern characteristics above 1 GHz for the electromagnetic wave radiated from multi-slot such as ventilations, etc. on the enclosure of an EUT and so to make recommendations for suitable test methods. An experimental EUT was formed by putting a comb-generator at the center of a rectangular enclosure with 4 slots, and its radiation pattern was analyzed in the frequency range of 1~6 GHz. As analysis results, multi-lobe appears above 2 GHz and the number of multi-lobes is growing as the frequency increases. And real radiated-emission measurements were performed for the experimental EUT by scanning a receiving antenna in the height of 1~4 m and tilting toward maximum radiation, as well as setting the height of a receiving antenna to the central position of the EUT which is prescribed at the present standards. The measured results are +12.8 dB in the scanning and +16.4 in the scanning and tilting compared with the present standard test method. Therefore, the latter must be revised in order to consider the radiation pattern above 1 GHz.

Modeling and Design Algorithm of Conducted EMI Filter Using a Noise Separation Method (노이즈 분리 기법을 이용한 진도EMI 필터의 모델링 및 설계 알고리즘)

  • 정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.260-266
    • /
    • 2004
  • Because the EMI filter is mainly designed by trial and error method, it takes many times to reduce the conducted EMI noise in a power converter. Thus, a newly analytical design procedure is proposed to overcome the problem in this paper. High frequency models of each component are built, md, using the modeling circuits, the filter design is carried out applicable to each mode. Based on the accumulated database for practical components, and the measurement data of EUT with a standard filter, the filler design algorithm is presented. Finally, the validity of the Proposed models and design method is verified through the measurement results.