• Title/Summary/Keyword: Echo arrangement

Search Result 9, Processing Time 0.035 seconds

Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering (대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

A Study on the Control of the Radiation Pattern of an Ultra-Sonic Beam by the Plural Arrangement of the Transducers (초음파진동자의 복수배열에 의한 지향성가변에 관한 연구)

  • 신형일
    • Journal of the Korean Institute of Navigation
    • /
    • v.3 no.2
    • /
    • pp.21-30
    • /
    • 1979
  • Echo sounder and Doppler sonar are to theultra-sonic transducers for measuring the depth and the ship's speed respectively. To measure the depth and speed with a single transducer, it is required to control the ultra-sonic beam to optional direction. In the past, the direction of the transducer itself is varied, but such a method provoked much problems in the mechanical design of the equipment. This paper deals with the method to control beam direciton by the phase control of the plural arrangement of transducers, and the results are studied by a computer simulation. The remarkable results of the study is condensed as follows; 1. The greater the interval of arrangement between transducers, the sharper the radiation pattern is, but in this case, the level of undesired sidelobe is also increased. 2. The control of radiation pattern up to 60 degree can be achieved by an adequate arrangement of more than 10 transducers. 3. It is shown that a simultaneous measurement of both depth and speed can be achieved by alternating directivity of the pulse by the method proposed in this paper.

  • PDF

Development of Split-beam Acoustic Transducer for a 50 kHz Fish Sizing Echo Sounder (50 kHz 체장어군탐지기용 분할 빔 음향 변환기의 개발)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.413-422
    • /
    • 2011
  • An improved split-beam transducer for a 50 kHz fish-sizing echo sounder was developed. The main objective of this study was to minimize the side lobe level in the beam pattern and the distance between acoustic centers for adjacent transducer quadrants in the geometrical arrangement of array elements while maintaining a given number of transducer elements and beam width. To achieve these goals, a 32-element planar array transducer ($6{\times}6$ array with one element in each corner missing) was designed using the Dolph-Chebyshev shading function to suppress side lobes in the array beam pattern and fabricated by arranging the inter-element spacing to be substantially equal to half the wavelength using the transducer element of 0.4 times the wavelength in diameter. The performance characteristics of this split-beam transducer were evaluated in the experimental water tank of $5m{\times}5m{\times}6m$ (length${\times}$height${\times}$width). In this study, the design goal of the beam width and side lobe level for transmitting a beam pattern was initially set at $21^{\circ}$ and -30 dB, respectively. However, the measured beam width at 3 dB was $21^{\circ}$ in both directions with side lobe levels of -24.7 dB in the horizontal plane and -25.6 dB in the vertical plane. The averaged beam width at -3 dB of the receiving beam patterns for four receiving quadrants was $31.4^{\circ}$. The transmitting voltage response was 161.5 dB (re $1{\mu}Pa$/V at 1 m) at 50.23 kHz with a bandwidth of 2.16 kHz, and the averaged receiving sensitivity for four receiving quadrants was -178.13 dB (re 1 V/${\mu}Pa$) at 49.8 kHz with a bandwidth of 2.64 kHz.

A Study on the Evaluation of Acoustic Performance for Music Room in Middle School Using Auralization (가청화를 이용한 중학교 음악실의 음향성능 평가에 관한 연구)

  • Soul, Soo-Hwan;Kang, Gyu-Sun;Kim, Jae-Soo
    • Journal of the Korean housing association
    • /
    • v.19 no.4
    • /
    • pp.49-57
    • /
    • 2008
  • The case study for this research is a middle school music room located in Iksan City, Korea. Although the room is used for teaching music, indiscreet sound-absorbing materials were applied within the space. Accordingly, a number of difficulties have been experienced when using the room. During a music lesson, the sound-volume is inadequate for music appreciation, while the music performance has an arid sound due to an insufficient echo. In order to control the obstructive factors resulting from a short Reverberation Time, the acoustic factor is optimized in this study by using an Acoustic Simulation, following an arrangement of Acoustic Design. A Psycho-acoustics Experiment was conducted using the Auralizational Technique, whereby the Virtual Acoustic Field can be experienced at the design stage.

Development of a New Cost-Effective Alignment Method for Speed Log and Echo Sounder System (결합형 속도 & 수심 측정기 고찰)

  • Park, Hyung Soo
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2015.09a
    • /
    • pp.28-33
    • /
    • 2015
  • Speed log measurement has always been of utmost importance to the mariners. To date the most accurate maritime speed measurement comes from Doppler measurement, where speed may be measured relative to either water(speed through water) or seabed(speed over ground). Recently, a clarification has been issued by the International Maritime Organization (IMO) regarding the speed measuring devices, which could ultimately impact the final arrangement of these devices for ships being constructed after July 1, 2014. This paper will discuss the clarification in depth and necessary action which shall be taken by the owners and operators of the ships impacted.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

A Study on the Evaluation of Acoustic Performance for Music Room in Middle School using Auralization (가청화(可聽化)를 이용(利用)한 중학교(中學校) 음악실(音樂室)의 음향성능평가(音響性能評價)에 관(關)한 연구(硏究))

  • Soul, Soo-Hwan;Kang, Gyu-Sun;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.272-275
    • /
    • 2008
  • In case a middle school music room locating in Iksan City, this space had been finished its construction work with the indiscreet sound-absorbing materials despite the music lesson is taught thereat. Accordingly, when music lesson since it sounds aridly due to insufficiency of echo and sound-volume feeling in music appreciation or music performance sound, there is some difficulty in the music lesson. For the purpose to control the obstructive factors owing to such short Reverberation Time, it optimizes the acoustic factor using Acoustic Simulation after arrangement of Acoustic Design, it has conducted a Psycho-acoustics Experiment using the Auralizational Technique that can experience the Virtual Acoustic Field at its designing stage. As the result of investigation about the acoustic satisfaction on the relevant subject space and the satisfaction with regard to the pertinent each items, it was known that the valuation on acoustic performance was evidently improved at 'after-reformation' than 'before-reformation'. It is considered that such material could be utilized as the useful material that can improve the architectural acoustic factor when construction and renovation of any middle school music room in the future.

  • PDF