• 제목/요약/키워드: Effective thermal conductivity

검색결과 303건 처리시간 0.038초

모래의 2 또는 3성분계의 유효열전도도 예측 모델 (A Model for Predicting Effective Thermal Conductivity of 2- or 3- Component Sand System)

  • 박상일
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.811-819
    • /
    • 1999
  • A theoretical model to predict the effective thermal conductivity of sands Is developed by considering the participating heat transfer mechanisms and their relationship to the model geometry. Comparison between the calculations and the measurements indicates that the assumptions to introduce two model constants (${\phi}_{af}$ and ${\delta}$) for model development were justified. As a results, the model was proved to predict the effective thermal conductivities of 2- and 3-component systems of two silica sands saturated with fluids or bonded with liquid binders in a reasonable accuracy.

미립자를 포함한 현탁액의 전단율에 의존적인 열전도율 측정 (Measurement of the Shear Rate-Dependent Thermal Conductivity for Suspension with Microparticles)

  • 이성혁;신세현
    • 대한기계학회논문집B
    • /
    • 제22권8호
    • /
    • pp.1141-1151
    • /
    • 1998
  • An effective thermal conductivity measurement for suspensions of microparticles in oil mixture is conducted in order to evaluate the shear rate-dependence of the thermal conductivity of suspensions. Measurements are made for rotating Couette flows between two concentric cylinders. The rotating outer cylinder is immersed into a constant temperature water bath while the stationary inner cylinder is subject to a uniform heat fluff. Test fluids are made to be homogeneous suspensions, in which neutrally buoyant microparticles ($d=25{\sim}300{\mu}m$) are uniformly dispersed. The present measurements show strong shear-rate dependent thermal conductivities for the suspensions, which are higher than those at zero shear rate. The shear rate dependent thermal conductivity increases with the particle size and volume concentration.4 new model for shear rate-dependent thermal conductivity of microparticle suspensions is proposed; the correlation covers from zero shear rate value to asymptotic plateau value at moderately high shear rates.

반밀폐형 지중열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Semi-Closed Loop Ground Heat Exchanger)

  • 김욱중;염한길;이춘우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.542-545
    • /
    • 2007
  • A semi-closed loop ground heat exchanger is proposed and its performance is compared through the measuring the effective thermal conductivity of the ground. In-situ tests based on the line source model are carried out to evaluate the thermal characteristics of each ground heat exchanger which has different penetration water flow rate. The test results show the increasing effective thermal conductivity of ground as the penetration water flow rate(PWFR) is increased. Therefore, the higher thermal performance of the proposed semi-closed ground heat exchanger can be expected.

  • PDF

두부의 전열물성 및 유효열전도도의 추정 2. 대두단상질의 고유열전도도 측정과 두부의 유효열전도도의 추정 (Thermophysical Properties of the Soybean Curd and Prediction of its Thermal Conductivity 2. The 'intrinsic' thermal conductivity of soybean protein and prediction of the thermal conductivity of soybean curd)

  • 공재열
    • 한국수산과학회지
    • /
    • 제15권3호
    • /
    • pp.219-225
    • /
    • 1982
  • 1) 2성분계 도지두부의 유효열전도도($\lambda_e$)를 $0\sim20^{\circ}C$$-5\sim-20^{\circ}C$의 범위내에서 측정한 결과, 수분함양의 증감에 따라 $\lambda_e$값도 증감했으며, 동결점이상의 온도대에서는 온도의 상승과 함께 $\lambda_e$값도 커지고, 동결점 이하에서는 온도의 하강과 함께 $\lambda_e$값이 커졌다. 2) 3성분계 두부의 유효열전도는 수분함양이 증가함에 따라 $\lambda_e$값은 커져가나 지질의 함양이 증가함에 따라 $\lambda_e$값은 작아졌다. $\lambda_e$값의 온도의존성은 2성분계도지두부의 경우와 유사했다. 3)대대단백질의 고유열전도도는 미동결상태에서 $\lambda_p=0.300[W/m{\bullet}k](0\sim-20^{\circ}C)$이고, 동결상태에서 $\lambda_p=0.488[W/m{\bullet}k](-5\sim-20^{\circ}C)$였으며 이들은 실험온도 범위내에서 온도의존성을 나타내지 않았다. 4) 대두단상질의 고유열전도도의 추정치 $\lambda_p=0.300$$\lambda_p=0.488$의 타당성을 지질의 함양이 상이한 2종류의 3성분계 두부에 적용한 결과, 실측치와 계산치는 잘 일치했다.

  • PDF

모델 단순화에 의한 CFRP 복합 구조물의 유효 열전도율 추출 방법 연구 (STUDY ON A EFFECTIVE THERMAL CONDUCTIVITY OF THE CFRP COMPOSITE STRUCTURE BY A SIMPLIFIED MODEL)

  • 김동건;한국일;최준혁;이장준;김태국
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.63-69
    • /
    • 2015
  • The thermal balance test in vacuum chamber for satellite structures is an essential step in the process of satellite development. However, it is technically and economically difficult to fully replicate the space environment by using the vacuum chamber. To overcome these limitations, the thermal analysis through a computer simulation technique has been conducted. The CFRP composite material has attracted attention as satellite structures since it has advantages of excellent mechanical properties and light weight. However, the nonuniform nature of the thermal conductivity of the CFRP structure should be noted at the step of thermal analysis of the satellite. Two different approaches are studied for the thermal analyses; a detailed numerical modeling and a simplified model expressed by an effective thermal conductivity. In this paper, the effective thermal conductivities of the CFRP composite structures are extracted from the detailed numerical results to provide a practical thermal design data for the satellite fabricated with the CFRP composite structure. Calculation results of the surface temperature and the thermal conductivities along x, y, z directions show fairly good agreements between the detailed modeling and the simplified model for all the cases studied here.

나노유체의 열전도율 측정과 열전달 향상 (Measuring Thermal Conductivity of Nanofluids and Heat Transfer Enhancement)

  • 이신표;최철;오제명
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.147-150
    • /
    • 2006
  • A new class of heat transfer fluid with higher thermal conductivity, called nanofluids has been developed by Dr. S. Choi about decade ago. Many exciting experimental and theoretical results have been reported worldwide to predict the thermal conductivity enhancement of nanofluids, however, they sometimes show excessive large discrepancies between each other. This kind of disagreements in thermal conductivity data is partly ascribable to the accuracy of the measuring apparatus, that is, mostly used THM(transient hot-wire method). New thermal conductivity measuring method whose principle is different from that of conventional THM is proposed in this article and measurements and uncertainty analysis were made for the three nanofluid samples with different particle concentration of pure, 2% and 4% of AlN nanofluids.

  • PDF

스탠딩컬럼웰형(SCW) 지중열교환기의 열성능 측정에 관한 실험적 연구 (An Experimental Study on the Thermal Performance Measurement of Standing Column Well type Borehole Heat Exchanger)

  • 이상훈;최용석;안근묵
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.122.2-122.2
    • /
    • 2010
  • Knowledge of ground thermal properties is most important for the proper design of BHE(borehole heat exchanger) systems. The configure type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for in-situ determination of design data for Standing Column Well apply. The main purpose has been to determine in-situ values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a sub-circulation pump, a boiler, temperature sensors, flow meter and a data logger for recording the temperature and circulation fluid flow data. A constant heating power is injected into the SCW through the test rig and the resulting temperature change in the SCW is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective in-situ values of rock thermal conductivity and thermal resistance of SCW.

  • PDF

3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구 (An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply)

  • 이상훈;박종우;임경빈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF

포화된 카올리나이트를 이용한 열전도계수 예측모델의 신뢰성 검토 (Assessment of the Models for Predicting the Thermal Conductivity of Saturated Kaolinite)

  • 이장근;김학승;강재모;김영석;배규진
    • 한국지반환경공학회 논문집
    • /
    • 제13권3호
    • /
    • pp.21-27
    • /
    • 2012
  • 동토를 대상으로 건설되는 지반구조물과 방사능 폐기물 처리장의 점토벽체의 성능을 결정하기 위해서는 정확한 세립토의 열전도계수 산정이 중요하다. 그러나 세립토의 경우 시료 성형과정에서의 교란, 포화상태 유지, 그리고 측정 장치의 장기발열로 인해 함수비 구배 발생과 같은 기존 열전도계수 측정 장비의 문제점으로 인해 열전도계수 측정에 오차가 발생한다. 본 연구에서는 압밀장비를 개조하여 열전도계수 측정용 니들프로브를 삽입한 상태에서 압밀시험을 활용하여 하중조건과 건조밀도의 변화에 따른 열전도계수를 연속적으로 측정하였다. 또한 실내실험 결과를 토대로 흙입자 구성성분의 열전도계수를 고려한 예측 모델의 신뢰성을 분석하였다.

국내 지중열전도도 측정 방법의 한계 및 개선 방향 (Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea)

  • 심병완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF