• Title/Summary/Keyword: Effervescent Atomizer

Search Result 6, Processing Time 0.025 seconds

Atomization Characteristics of Effervescent Atomizer with the Variations of Operating Conditions (작동조건 변화에 따른 기체주입미립화기의 미립화 특성)

  • Kim, Hyung-Gon;Yano, Toshiaki;Song, Kyu-Keun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.869-874
    • /
    • 2003
  • The atomization characteristics were investigated through the influence of the change of GLR and the change of working fluid on droplet size distribution and mean diameter of drop produced by effervescent atomizer. For simultaneous injection of water and high viscous waste vegetable oil, effervescent atomizer with two aerator tubes was specially designed. From the experimental results, regardless of mass fraction of vegetable oil in working fluids, it is expected that effervescent atomizer will exhibit excellent atomization performance at the high GLR conditions.

  • PDF

Spray characteristics of effervescent atomizer with internal flows (Effervescent atomizer의 내부 유동에 따른 분무특성)

  • Ku, K.W.;Hong, J.G.;Kim, J.H.;Lee, C.W.;Park, C.D.;Lim, B.J.;Chung, K.Y.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.123-124
    • /
    • 2012
  • Effervescent atomizer in which the liquid is ejected from nozzle with bubble caused by gas injection into the liquid is one of twin-fluid atomizers. Effervescent atomizer is operated with the lower injection pressure and the smaller air flow rate when compared with those of other twin-fluid atomizers. In this study, we attempted experiment study to investigate the atomization characteristics of effervescent atomizer related with the internal flow condition. The nozzle was made with acrylic material to investigate the nozzle internal flow. The macroscopic spray analysis was conducted with internal flow images and spray images. Furthermore, SMD was measured by using the laser diffraction method. According to this study, the internal flow condition changed from bubbly flow to annular flow as the air-liquid mass ratio(ALR) increases. At that time, the atomization characteristics were improved.

  • PDF

Microscopic Spray Characteristics in the Effervescent Atomizer with Two Aerator Tubes

  • Kim, Hyung-Gon;Toshiaki Yano;Song, Kyu-Keun;Torii Shuichi
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1661-1667
    • /
    • 2004
  • An experimental study is performed on atomization characteristics and stable operating conditions for the injection of high viscous waste vegetable oil using an effervescent atomizer with 2 aerator tubes. Consideration is given to the effects of ALR and liquid viscosity on the velocity and mean diameter of the injected droplet. It is found that (i) as ALR increases, the axial velocity of the droplet is increased, while half-velocity width and SMD are decreased regardless of the change in liquid viscosities, (ii) the rate of fine drop distribution occupied in the total spray field is increased with an increase in ALR, and (iii) the effect of viscosity on the atomization characteristics is minor. Consequently, it is expected that the effervescent atomizer will exhibit an excellent atomization performance at the high ALR condition, regardless of liquid viscosities.

Experimental Study on the Spray Characteristics of Aerated Impinging Jets (기체주입 충돌제트의 분무특성에 관한 실험적 연구)

  • Lee, Keunseok;Yoon, Youngbin;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.24 no.4
    • /
    • pp.185-193
    • /
    • 2019
  • The effervescent atomizer is one of twin-fluid atomizers that aeration gas enters into bulk liquid and two-phase flow is formed in the mixing section. The effervescent atomizer requires low injection pressure and small amount of aeration gas, as compared to other twin-fluid atomizers. In this study, cold flow test was conducted to investigate the spray characteristics of aerated impinging jets. The present effervescent impinging atomizers were composed of the aerator device and like-on-like doublet impinging atomizer which had different impinging angles. To analyze the spray characteristics such as breakup length and droplet size distribution, the image processing technique was adopted by using instantaneous images at each flow condition. Non-dimensional parameters, induced by the homogeneous flow model, were used to predict the breakup length. The breakup length was decreased with the mixture Reynolds number and impinging angle increasing. The result of droplets showed that the size distribution was axisymmetric about the center of the injector and their diameter tended to decrease with increasing GLR.

A Study on the Atomization Characteristics of Effervescent Atomizer with PDPA (PDPA를 이용한 기체주입미립화기의 미립화 특성에 관한 연구)

  • Kim, Hyung-Gon;Yano, Toshiaki;Song, Kyu-Keun;Jung, Byong-Koog;Jung, Jae-Youn;Cho, Tae-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1316-1321
    • /
    • 2004
  • An experimental study is performed on atomization characteristics and stable operating condition for injection of high viscous waste vegetable oil using effervescent atomizer with two aerator tubes. Consideration is given to the effects of ALR and liquid viscosity on the velocity and mean diameter of the injected droplet. It is found that (i) as ALR increases, the axial velocity of the droplet is increased, while half-velocity width and SMD are decreased regardless of the change in liquid viscosities, (ii) the rate of fine drop distribution occupied in the total spray field is increased with an increasing in ALR, and (iii) the effect of viscosity on atomization characteristics is minor.

  • PDF

Identification of Internal Flow Pattern in Effervescent Atomizers (기체주입노즐의 내부유동양식의 구분)

  • Kim, Joo-Youn;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.306-315
    • /
    • 2000
  • An experimental study was conducted to examine the internal flow patterns inside the mixing chamber of effervescent atomizers. The mixing chamber has the rectangular cross section ($8mm{\times}2mm$) and made of transparent acrylic plate for flow visualization. The parameters tested were the air/liquid ratio (ALR), injection. pressure, and the nozzle orifice diameter. Three different flow regimes were observed; bubbly, annular, and intermittent flows. In the bubbly flow regime, the discharged mixture was disintegrated into drops through the bubble expansion and the ligament breakup. On the other hand, in the annular flow regime, the liquid annulus was disintegrated into small drops by the aerodynamic interaction between the phases due to the high relative velocities between the gas and the liquid. In the intermittent flow regime, the bubble-expansion/ligament-disintegration mode and the annulus-disintegration mode appeared alternatively. The correlations representing the transition criteria between the two-phase flow patterns within the mixing chamber were proposed based on the drift-flux models.