• Title/Summary/Keyword: Electric Precipitation

Search Result 101, Processing Time 0.025 seconds

Analysis on Wearing Characteristics of Main Wearing Slider for Pantograph According to Precipitation (강수의 영향에 따른 Pantograph 주습판의 마모특성 분석)

  • Kim, Kyung-Seob;Kim, Kwan-Soo;Cho, Kwan-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.994-999
    • /
    • 2011
  • The main wearing slider of pantograph is a difference which is considerable to wear phenomenon according to material properties. Especially, Cu-type wearing slider suddenly occurs the abnormal wear by precipitation, this threatens the travelling safety of the train. The abnormal wear by precipitation and arc influences are main factor decided to life time of Cu-type wearing slider and contact wire. Consequently, the application of the main wearing slider with wear resisting capacity, electrical conductivity, resistance arc and lubrication is demanded. In this paper through tribologic approach, overcame abnormal phenomenon of the Cu-type wearing slider by the precipitation and for the economic efficient augmentation by durability improvement and the travelling safety were accomplished. The Cu-type wearing slider which has excellent electric conductivity and arc characteristic but it occurs the normal and abnormal wear phenomenon according the precipitation which changes, respectively. Consequently, this phenomenon grasps fixed quantity according to precipitation, a mileage and wear volume then Fe-type wearing slider compared and analyzed.

  • PDF

Turbulent Particle Dispersion Effects on Electrostatic Precipitation (전기집진에서의 난류 입자 이산)

  • Choe, Beom-Seok;Fletcher C.A.J
    • 연구논문집
    • /
    • s.28
    • /
    • pp.39-47
    • /
    • 1998
  • Industrial electrostatic precipitation is a very complex process, which involves multiple-way interaction between the electric field, the fluid flow, and the particulate motion. This paper describes a strongly coupled calculation procedure for the rigorous computation of particle dynamics during electrostatic precipitation. The turbulent gas flow and the particle motion under electrostatic forces are calculated by using the commercial computational fluid dynamics (CFD) package FLUENT linked to a finite-volume solver for the electric field and ion charge. Particle charge is determined from both local electrical conditions and the cell residence time which the particle has experienced through its path. Particle charge density and the particle velocity are averaged in a control volume to use Lagrangian information of the particle motion in calculating the gas and electric fields. The turbulent particulate transport and the effects of particulate space charge on the electrical current flow are investigated. The calculated results for poly-dispersed particles are compared with those for mono-dispersed particles, and significant differences are demonstrated.

  • PDF

A study on electric current variation characteristics during Electrokinetic remediation of kaolinite contaminated by Pb (납으로 오염된 카올린의 Electrokinetic 정화기법 적용시 전류변화 특성에 관한 연구)

  • 김정환;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.302-306
    • /
    • 2000
  • In case of applying electrokinetic remediation, magnitude of electric current is one of major factors for estimation of contaminant transport. In practice, electric current provide determination of electric conductivity based on specimen resistance. Electric current variation is produced during Electrokinetic remediation test. Electric current is decreased by expotential function according to time in condition of constant voltage. This can be interpreted as precipitation effect by OH$^{-10}$ generation in a cathode.

  • PDF

Effective Oxidant Generation and Ion Precipitation Characteristics of Electrolyzing Cell by Discharge and Space Charge Control (수중 방전과 공간전하제어에 의한 효과적인 산화성물질 발생특성)

  • Kim, Jin-Gyu;Lee, Dae-Hee;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.9-12
    • /
    • 2000
  • A new type electrolyzing cell with slits on parallel plate electrodes and wire-to-cylinder type electrode system has been proposed instead of the conventional parallel plate type. An investigation was carried out on the effect of the number and size of slits on ion precipitation and oxidant generation characteristics, evidenced by eliminated space charge limiting action and by elevated electric fields in active interelectrode spacing. And it is also studied on the effect of the diameter of wire electrode to ion precipitation and oxidant generation characteristics. With electrode with 48 slits, very oxidants generation water of 3.1 [ppmm] and 19.0 [ppmm] in positive electrode side were obtained with tap water and 0.1 [wt%] NaCl dissolved tap waterfed. In addition, with wire-to-cylinder type electrode system, it is found that oxidant contained water of 0.48 [ppmm] and 5.46 [ppmm] in positive electrode side were obtained with tap water and 0.1 [wt%] NaCl dissolved tap water fed for the case of discharge electrode diameter of 0.5 [$mm{\phi}$]. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits on the electrodes of conventional cell as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode spacing.

  • PDF

Interpretation of Chemistry Analytical Data in Precipitation (강수중 화학성분 분석자료의 해석)

  • 강공언;전종남;김희강
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.62-68
    • /
    • 1996
  • Precipitation samples were collected by the wet-only event sampling method at Seoul from September 1991 to April 1995. Concentrations of samples for the ion components($NO_3^-, NO_2^-, SO_4^{2-}, Cl^-, F^-, Na^+, K^+, Ca^{2+}, Mg^{2+}$ and $NH_4^+$) were measured in addition to pH and electric conductivity. During the sampling period, 182 samples were collected, but only 163 samples were identified as valid. The pH, calculated from the volume-weighted $H^+$ concentration, was found to be 4.7, indicating a relatively intensive acidity compared with data from other regions of the world, where acid deposition was known to be a problem. Above all, the concentration of non-seasalt sulfate was $84 \mu eq/L$, which was the highest compared to that measured in other regions of the world. The major acidifying ions in the precipitation at Seoul were identified as sulfate and nitrate except for chloride, because the Cl/Na ratio in the precipitation was close to the ratio in seawater. If all of the non-seasalt sulfate and nitrate existed in the form of sulfuric and nitric acids, respectively, the average pH in the precipitation was calculated as 3.7, lower than the measured value. Consequently, the difference between the calculated and measured pH suggest that the acidity of precipitation was neutralized by alkaline species, not due to the low contribution of an anthropogenic air pollutants to the precipitation. The equivalent concentration ratio of sulfate to nitrate was 3.5, which indicated that the contributions of sulfuric and nitric acids to the precipitation acidity were 78% and 22%, respectively.

  • PDF

Acidity and Chemical Composition of Precipitation at Background Area of the Korean Peninsula (Anmyeon, Uljin, Gosan) (한반도 배경지역 (안면, 울진, 고산) 상수의 산성도와 화학특성)

  • Kim, Sang-Baek;Choi, Byoung-Cheol;Oh, Suk-Yeong;Kim, San;Kang, Gong-Unn
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.15-24
    • /
    • 2006
  • Precipitation samples were collected at Anmyeon (1997 - 2004), Uljin, and Gosan (1998 ~ 2004), the background area of the Korean Peninsula. These samples were analyzed for the concentration of 9 major ionic components ($F^{-}$,$Cl^{-}$, $NO_{3}^{-}$, $SO_{4}^{2-}$, $Na^{+}$, $NH_{4}^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$) with including a pH and an electric conductivity. Data quality for these samples was verified by ion balance and conductivity balance which are based on GAW manual for precipitation chemistry and the number of valid data at Anmyeon, Uljin, and Gosan is 249, 173, and 188, respectively. During the study period, the precipitation-weighted average pH at Anmyeon, Uljin, and Gosan was found to be 4.81, 4.87 and 4.89, respectively and each annual average pH was showed below pH 5.6 for every site. From the frequency survey on the precipitation acidity, the occurrence rate of acid rain below pH 5.6 is greater than $80\%$ for every site. Particularly, the highest occurrence rate for strong acid rain below pH 4.5 was found at Anmyeon, $32.1\%$, compared with other sites ($10.4\%$ at Uljin, $15.4\%$ at Gosan). That's because acidifying species (nss-$SO_{4}^{2-}$, $NO_{3}^{-}$) are remarkably high concentration at Anmyeon.

A study on Removal Method of Humidifier Particles Using Electrostatic Precipitation Technology

  • Inpyo Cha;Taekeon Jung;Hyunjun Yun;Chuljun Choi
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.239-245
    • /
    • 2023
  • In this research, our objective was to investigate the efficacy of electrostatic precipitation in capturing mist particles. We assumed that it could be helpful in multi-functional facilities and similar environments where both humidification and dehumidification are required. We derived the air density of the humidified air based on its properties using Dalton's law. The analysis was performed to evaluate the collection efficiency of capturing mist aerosols of various sizes. As a result, we revealed that under the conditions of a dry-bulb temperature of 26.0℃ and relative humidity of 8%, the system achieved a collection efficiency of 99.999% or more for aerosols larger than 2.5㎛. These results indicate that electrostatic precipitation technology shows great promise as an effective method for capturing mist particles.

A Study on the Effect of Magnetic Field in Electrostatic Precipitator for Improving Precipitation Efficiency of Particulate Matter (미세먼지의 집진효율 향상을 위한 전기집진기의 자계인가특성에 대한 연구)

  • Park, Jae-Youn;Han, Sang-Bo;Park, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.122-129
    • /
    • 2008
  • This paper gives the experimental results for the effective precipitation of particulated matter(PM) below 1[${\mu}m$] of diameter using the electrostatic precipitator, which is designed by ourselves. In order to improve the precipitation efficiency, the vertical and parallel magnetic field to the electric field is applied simultaneously by arranging ferrite magnets. When the parallel magnetic field is applied, the precipitation efficiency does not improve in comparison with non-magnets. However, when the vertical magnetic field is applied, it is improved about 5[%] more than the case of non-magnetized ferrite plate used. In addition, when the magnets are installed at the center of ground plate electrodes, the precipitation efficiency is ranged from 17 to 32[%] under the applied voltage of 5[kV]. It is similar to the case of the magnet arrangement at the front part of ground electrode. Also, the precipitation efficiency is more improved by arranging magnets as the inside part and zigzag on the electrodes. Especially, large particles of 0.7 and 1[${\mu}m$] is more easily captured by electrostatic precipitator. Consequently, it is convinced that the vertical magnetic field is more desirable than parallel magnetic field on the electric field for the effective treatment of particulated matter.

A High Effeciency Functional Water Generation Characteristics by Corona Discharge and Space Charge Control (코로나방전과 공간전하제어에 의한 고효율 기능수 발생특성)

  • 김진규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.101-107
    • /
    • 2002
  • A novel oxidant generation and ion precipitation cell with slits on parallel plate electrodes was proposed instead of the conventional parallel plate type. An investigation was carried out on the effect of the number and size of slits on ion precipitation and oxidant generation characteristics, evidenced by eliminated space charge limiting action and by elevated electric fields in active interelectrode sparing. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits un the electrodes of conventional cells as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode spacing.

An Analysis of Long-term Trends in Precipitation Acidity of Seoul, Korea (서울지역 강수 산성도의 장기적인 경향분석)

  • 강공언;임재현;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.1
    • /
    • pp.9-18
    • /
    • 1997
  • Precipitation samples were collected by the wet- only event sampling method from Seoul during September 1991 to April 1995. These samples were analyzed for the concentrations of the major ionic components (N $O_3$$^{[-10]}$ , N $O_2$$^{[-10]}$ , S $O_4$$^{2-}$, C $l^{[-10]}$ , $F^{[-10]}$ , N $a^{+}$, $K^{+}$, $Ca^{2+}$, $Mg^{2+}$, and N $H_4$$^{+}$), pH, and electric conductivity. During the study period, a total of 182 samples were collected, but only 163 samples were used for the data analysis via quality assurance of precipitation chemistry data. The volume-weighted pH was found to be 4.7. The major acidifying species from our precipitation studies were identified to be non-seasalt sulfate (84$\pm$9 $\mu$eq/L) and nitrate (24$\pm$2 $\mu$eq/L) except for chloride. Because the Cl/Na ratio in the precipitation was close to the ratio in seawater. If all of the non-seasalt sulfate and nitrate were in the form of sulfuric and nitric acids, the mean pH in the precipitation could have been as low as 3.7 lower than the computed value. Consequently, the difference between two pH values indicate that the acidity of precipitation was neutralized by alkaline species. The equivalent concentration ratio of sulfate to nitrate was 3.5, indicating that sulfuric and nitric acids can comprise 78% and 22% of the precipitation acidity, respectively. Analysis of temporal trend in the measured acidity and ionic components were also performed using the linear regression method. The precipitation acidity generally showed a significantly decreasing trend, which was compatible with the pattern of the ratio (N $H_4$$^{+}$+C $a^{2+}$)/ (nss-S $O_4$$^{2-}$+N $O_3$$^{[-10]}$ ).).

  • PDF