• 제목/요약/키워드: Electric probe

검색결과 230건 처리시간 0.035초

Langmuir Probe를 이용한 유도결합형 플라즈마의 측정 (Measurement of Inductively Coupled Plasma Using Langmuir Probe)

  • 이영환;조주웅;김광수;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1719-1721
    • /
    • 2003
  • In this paper, electrical characteristics of inductively coupled plasma in an electrodeless fluorescent lamp were investigated using a Langmuir probe with a variation of Ar gas pressure. The RF output was applied in the range of 5-50W at 13.56MHz. The internal plasma voltage of the chamber and the probe current were measured while varying the supply voltage to the Langmuir probe in the range of -100V ${\sim}$ +100V. When the pressure of Ar gas was increased, electric current was decreased. There was a significant electric current increase when the applied RF power was increased from 10 W to 30 W. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

  • PDF

2D-ICP(inductively coupled plasma)에서 정전 탐침 삽입 시의 플라즈마 수치 계산 (Numerical Modeling of Perturbation Effects of Electrostatic Probe into 2D ICP(inductively coupled plasma))

  • 주정훈
    • 한국표면공학회지
    • /
    • 제44권1호
    • /
    • pp.26-31
    • /
    • 2011
  • Numerical modeling is used to investigate the perturbation of a single Langmuir probe (0.2 mm diameter shielded with 6 mm insulator) inserted along the center axis of a cylindrical inductively coupled plasma chamber filled with Ar at 10 mTorr and driven by 13 MHz. The probe was driven by a sine wave. When the probe tip is close to a substrate by 24.5 mm, the probe characteristics was unperturbed. At 10 mm above the substrate, the time averaged electric potential distribution around the tip was severly distorted making a normal probe analysis impossible.

돼지의 계류시간, 전살전압 및 도체냉각조건에 따른 PSE 발생율 비교 (Comparison of Incidence of PSE Pork by Lairage Time, Use of Electrical Probe, Stunning Voltage and Chilling Condition)

  • 박범영;조인철;김일석;김진형;조수현;유영모;이종문;윤상기
    • 한국축산식품학회지
    • /
    • 제23권1호
    • /
    • pp.28-31
    • /
    • 2003
  • 동일 냉각조건하에서 계류 유무 및 전기봉 사용 유무에 따른 PSE 발생율을 조사한 결과 전일 계류를 실시하고 전기 봉을 사용하지 않았을 때 PSE 발생율은 22.2%이었으나, 계류하지 않고 전기봉을 사용한 경우 59.3%로 발생율이 37.1%가 증가되었다. 이러한 결과는 무계류로 인하여 PSE 발생율이 증가되었을 뿐만 아니라 더불어 전기봉 사용으로 더 높은 PSE 발생율을 야기시킨 것으로 보인다. 저전압(230 V) 전살 조건을 적용하였으며, 이때 PSE 발생율은 42.37%로 고전압 (500 V) 전살조건을 적용한 도축라인에서는 66.67%였다. 따라서 전살조건 및 도축라인에 따른 PSE 발생율 차이는 24. 3%인 것으로 조사되었다 예냉후 등심 심부온도 관리에 따른 PSE 발생율을 조사한 결과 도축 처리장에서 예냉(도축후 70분)후 등심 심부온도를 38$^{\circ}C$ 이상으로 관리시 PSE 발생율은 52.2%였으나, 3$0^{\circ}C$ 이하로 관리하였을 때 발생율은 39.6 %로 예냉후 심부온도를 3$0^{\circ}C$ 이하로 관리함으로써 PSE 발생율을 12.6% 감소시킬 수 있었다. 그리고, PSE 발생율은 도체중과는 무관하였다.

발전기 운전중 회전자 진단에 관한 연구 (On-Line Diagnosis Method for Generator Rotor Windings)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2002
  • A shorted-turn test was performed at the Sininchon combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line diagnosis system. The flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

발전기 운전중 회전자 계자권선의 단락 진단기법에 관한 연구 (Shorted-Turn Detction Techniques for Generator Rotor)

  • 이영준;김희동;빅종정;주영호;조지원;이병하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1721-1724
    • /
    • 1998
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas. turbine generator #4. The test was conducted using a permanent flux probe and digital oscilloscope. The flux probe installed in the generator air gap, senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a waveform analysis technique that can identify the pole location, slot number, and number of shorted-Turns with each slot.

  • PDF

전계를 이용한 기억장치 전극의 최적 설계 (Optimal Design of Electrical Probe of Record Device using Electric Field)

  • 이성구;최재학;김용수;이주;최승길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.899-901
    • /
    • 2004
  • This paper analyzes recording density according to the shape variation of Electric Probe writer, and present a shape design method for improving recording density in perpendicular electric recording device. The gradient of electric field has to be steep to improve recording density because transition region on the media becomes wider when recording. The optimum shape of electrode could be archived by using Response Surface Methodology and 2-Dimensional Finite Element Method.

  • PDF

발전기 회전자 권선 층간단락 진단에 관한 연구 (Shorted-Turn Test for Generator Rotor Windings)

  • 이영준;공태식;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1747-1749
    • /
    • 2003
  • 발전기 회전자 권선에 종종 발생하는 층간단락 현상을 찾아내는 진단기법에는 크게 두가지가 있으며, 정지중 진단기법인 분담전압 시험과 운전중 진단기법인 flux probe 시험이다. 본 논문에서는 서인천복합화력발전소 #2 스팀터빈 발전기에 대하여 분담전압 및 flux probe 시험을 시행하여 회전자 권선의 건전성을 확인하고, 그 결과를 상호 비교, 분석하여 정지중 및 운전중 진단기법의 신뢰성을 평가하였다.

  • PDF

아르곤 압력에 따른 유도결합형 폴라즈마의 전기적 특성 (Electrical Properties of Inductively Coupled Plasma by Argon Pressurebstract)

  • 이영환;허인성;조주웅;김광수;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.89-91
    • /
    • 2003
  • In this paper, using a Langmuir probe Ar gas characteristic of electrodeless fluorescent lamp which used an inductively coupled plasma were investigated. The RF output changed into 5-50W in 13.56MHz. At this time internal plasma voltage of the chamber and probe current were measured while changing in -70V - +70V with a supply voltage by Langmuir probe. If pressure of Ar gas was increased, the electric current tended to decrease. Also, an electric current was increased according to an increase of a RF output.

  • PDF