• Title/Summary/Keyword: Electrical potential energy

Search Result 544, Processing Time 0.025 seconds

Potential Electrical Energy Saving by Stand-by Power Measurement (대기전력 측정을 통한 절전 잠재량 예측)

  • 최재원;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.253-255
    • /
    • 1999
  • We measured stand-by power of electrical machinery and appliance which are used at office and house. And we estimated potential electrical energy saving through stand-by power and the expecting number of supplied apparatus. As a result, We can reduce electrical energy by minimizing a stand-by power consumption up to three billion kWh which are equal to about 1/3 of an atomic power plant's generating power of 1 year.

  • PDF

Influence on Meridians Electric Potential for Electrical Ground and Insulation (-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

Effects of the Counter Ion Valency on the Colloidal Interaction between Two Cylindrical Particles

  • Lee, In-Ho;Dong, Hyun-Bae;Choi, Ju-Young;Lee, Sang-Yup
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.3
    • /
    • pp.567-572
    • /
    • 2009
  • In this study, the effects of counter ion valency of the electrolyte on the colloidal repulsion between two parallel cylindrical particles were investigated. Electrostatic interactions of the cylindrical particles were calculated with the variation of counter ion valency. To calculate the electrical repulsive energy working between these two cylindrical particles, Derjaguin approximation was applied. The electrostatic potential profiles were obtained numerically by solving nonlinear Poission-Boltzmann (P-B) equation and calculating middle point potential and repulsive energy working between interacting surfaces. The electrical potential and repulsive energy were influenced by counter ion valency, Debye length, and surface potential. The potential profile and middle point potential decayed with the counter ion valency due to the promoted shielding of electrical charge. On the while, the repulsive energy increased with the counter ion valency at a short separation distance. These behaviors of electrostatic interaction agreed with previous results on planar or spherical surfaces.

A Study on the Installation Potential of Photovoltaic System Based on Regional Architectural Data (지역별 건축물 데이터를 활용한 태양광발전시스템 설치 잠재량 산정에 관한 연구)

  • Shin, Min-Su;Lee, Kyung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.3
    • /
    • pp.29-45
    • /
    • 2019
  • As the solar energy market grows, the need to investigate the potential of photovoltaic system is being highlighted. However, due to the lack of plain field, the system on top of buildings is being exploited. This paper analyzes the potential to install PV systems on the rooftops. First of all, with the aid of a photovoltaic system simulation software, buildings were designed in a specific area based on the architectural data. And then, with the same software, the potential to install photovoltaic system was explored by placing PV modules on the buildings' rooftops. The installation potential was calculated and simulated with consideration for obstacles on the rooftops. The parameters are composed of available area for system installation, area utilization rate, PV system power capacity, operation yield hour per day and performance ratio. In the simulation, 5 sites were analyzed based on their architectural data. In the end, reliable data that can be utilized were collected for the potential to install the system with the photovoltaic system simulation software.

Interfacial Electrical Studies on Adhesion of Hematite Particle to Polyester Fabric and its Removal from the Fabric(Part I) -The interaction energy between particle and fabric- (Polyester직물에의 Hematite입자의 부착과 제거에 관한 계면전기적 고찰(제1보) -기질과 입자간의 상호작용에너지-)

  • Kang, In-Sook;Kim, Sung-Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.3
    • /
    • pp.380-390
    • /
    • 1993
  • Effect of interfacial electrical conditions on adhesion of ${\alpha}-Fe_2O_3$ particles to PET fabric and the removal of ${\alpha}-Fe_2O_3$ particles from PET fabric, were investigated as functions of pH, electrolyte and ionic strength. The ${\zeta}$ potential of PET fiber and ${\alpha}-Fe_2O_3$ particles in the electrolyte solution were measured by streaming potential and microelectrophoresis methods respectively. The potential energy of interaction between ${\alpha}-Fe_2O_3$ particles and PET fabric were calculated by using the heterocoagulation theory for a sphere-plate model. The negative ${\zeta}$ potential of ${\alpha}-Fe_2O_3$ particle and PET fiber increased with pH, and then decreased certain pH and isoelectric points of ${\alpha}-Fe_2O_3$ particles and PET fiber were pH 6.5 and pH 3.5, respectively. The negative ${\zeta}$ potential of ${\alpha}-Fe_2O_3$ particle and PET fiber affected by electrolytes, were relatively high with polyanion electrolytes in solutions and were low with neutral salts. However, at surfactant solution, ${\zeta}$ potential was levelled off. The influence of the ionic strength on the ${\zeta}$ potential of ${\alpha}-Fe_2O_3$ particle was small but the negative ${\zeta}$ potential of PET fiber increased with the ionic strength. In the presence of anionic surfactant, the ${\zeta}$ potential of ${\alpha}-Fe_2O_3$ particle and PET fiber increased regardless of solution conditions. The interaction energy between ${\alpha}-Fe_2O_3$ particle and PET fabric increased with pH. The interaction energy was relatively high with polyanion electrolytes in solution, and the influence of ionic strength on the interaction energy was small, and the effective thickness of electrical double layer increased with decreasing the ionic strength.

  • PDF

Designing Fault-Tolerant Gaits for Quadruped Robots Using Energy Stability Margins (에너지 안정여유도를 이용한 사족 보행 로봇의 내고장성 걸음새)

  • Yang, Jung-Min
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.319-326
    • /
    • 2006
  • This paper proposes a novel fault-tolerant gait for Quadruped robots using energy stability margins. The previously developed fault-tolerant gaits for quadruped robots have a drawback of having marginal stability margin, which may lead to tumbling. In the process of tumbling, the potential energy of the center of gravity goes through a maximum. The larger the difference between the potential energy of the center of gravity of the initial position and that of this maximum, the less the robot tumbles. Hence this difference of potential energy, dubbed as Energy Stability Margin (ESM), can be regarded as the stability margin. In this paper, a novel fault-tolerant gait is presented which gives positive ESM to a quadruped robot suffering from a locked joint failure. Positive ESM is obtained by adjusting foot positions between leg swing sequences. The advantage of the proposed fault-tolerant gait is demonstrated in a case study where a quadruped robot with a failed leg walks on a even slope.

DSM Potential Evaluation and Procedures on Commercial Sector (업무용 부문의 DSM 잠재량 평가절차 및 절전잠재량 추정)

  • Rhee, Chang-Ho;Park, Jong-Jin;Jo, In-Seung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.531-537
    • /
    • 1999
  • This paper presents the evaluaton procedures and the estimation model for DSM potential on commercial sector in Korea. In general, the evaluation process of the potential savings for DSM measures or programs consists of baseline electricity consumption forecast and potential evaluation such as technical potential(TP), economic potnetial(EP), and achievable potential(AP). A library of energy conservation measures applicable to each end-use or apparatus is developed, and energy savings and other factors are applied to the baseline demand estimates of consumption to produce potential savings estimates. The purpose of this paper is to establish the evaluation process of those DSM potential for commercial sector. In case study, we applied it to commercial sector for horizon years by end-use.

  • PDF

Development of DSM Potential Evaluation Procedures and Algorithm (DSM 잠재량 평가절차 및 알고리즘 개발)

  • Rhee, Chang-Ho;Park, Jong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.917-919
    • /
    • 1997
  • Recently, electric industry confront a strategical change and high competiveness environment in the course of deregulation. Especially, rapid growth in electricity demand, financial need for new power plant construction, and environmental problems have led to search for more efficient energy production and energy conservation technologies in Korea. Due to the potential energy and cost savings, DSM(Demand-Side Management) plays and important role in the electric resource planning. In this paper, we suggest DSM potential evaluation procedures and algorithm. Also, we present screening analysis methods for DSM potential evaluation.

  • PDF

Estimation of the Energy Saving Potential using Energy Bandwidth Analysis in Manufacturing Plant (에너지 대역분석 기법을 이용한 생산플랜트에서 에너지절감 잠재량 산정)

  • Park, Hyung-Joon;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.236-240
    • /
    • 2011
  • Currently one of the most importance issues in industrial sector is energy cost and energy efficiency. The manufacturing plants especially have made many efforts to reduce energy cost by implementing maintenances. But in many cases, they are not aware that how much energy could be saved more. If we know the best energy consumption, which signifies energy baseline, we can control the intensity of maintenances. One way to obtain the baseline is using proper statistics from a specific plant, a sector of industry. Energy bandwidth signifies the gap between actual Specific Energy Consumption(SEC) of a certain plant and minimum SEC of the best plant, and estimate energy saving potential(ESP) is a result of bandwidth analysis. We chose a model plant and implemented some maintenance for a year, and then we obtained ESP. Additionally we could determine the decreased amount of carbon emissions from the plant using Carbon Emissions Factor(CEF) by Intergovernmental Panel on Climate Change(IPCC).

General Analytical Method for Magnetic Field Analysis of Halbach Magnet Arrays Based on Magnetic Scalar Potential

  • Jin, Ping;Yuan, Yue;Lin, Heyun;Fang, Shuhua;Ho, S.L.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.95-104
    • /
    • 2013
  • This paper presents a general analytical method for predicting the magnetic fields of different Halbach magnet arrays with or without back iron mounted on slotless permanent magnet (PM) linear machines. By using Fourier decomposition, the magnetization components of four typical Halbach magnet arrays are determined. By applying special synthetic boundary conditions on the PM surfaces, the expressions of their magnetic field distributions are derived based on the magnetic scalar potential (MSP), which are simpler than those based on the magnetic vector potential (MVP). The correctness of the method is validated by finite element analysis. The harmonics of airgap flux density waveforms of these Halbach magnet arrays with or without back iron are also compared and optimized.