• Title/Summary/Keyword: Electromagnetic disturbance

Search Result 53, Processing Time 0.03 seconds

Compensation of a Spindle Disturbance using an Electromagnetic Exciter (전자기 가진기를 이용한 스핀들 외란 보상 제어)

  • 안재삼;이선규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.329-329
    • /
    • 2000
  • In this paper, a spindle system using an electromagnetic exciter is proposed to compensate a spindle disturbance such as unbalance and machining force etc A spindle compliance can be readily varied with a disturbance which is generated by the interact ion between the spindle / workpiece structure and the cutting process dynamics. The varied compliance is one of the major constraints that deteriorates the surface quality of workpiece. This paper suggests a compliance compensation by using the EME in the proposed spindle system. To compensate the varied compliance, firstly a spindle system modeling was conducted by using the bond graph. Then the model is simulated by numerical analysis method and an optimal EME position is determined to compensate a disturbance effectively through simulation, which makes the bearing load to be minimized

  • PDF

A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters (유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

Calculating Emission Power Limits of Electromagnetic Disturbance Signal for Embedded Systems in ISM Bands (ISM 밴드용 임베디드 기기를 위한 전자기 혼신신호의 송신전력 제한치 도출)

  • Cho, Myeon-Gyun;Kim, Shik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.5 no.3
    • /
    • pp.136-143
    • /
    • 2010
  • Embedded systems widely used for wireless communication such as W-LAN, Bluetooth and ZigBee operate on ISM (Industrial, Scientific and Medical) band but they can be seriously affected by electromagnetic interference radiated from ISM apparatus. Therefore C.I.S.P.R. reports proposed limits for the protection of telecommunication from interference from ISM equipment. In this paper, we clarify the methods for calculating limits for disturbance signal for Embedded Systems in ISM band and propose simple way of calculating limits for interference signal in both above and below 1 GHz band cases.

Reduction of Power Disturbance by Contact Loss Phenomenon of a High Speed Electric Train Using Passive Filters (수동필터를 이용한 고속전철 이선현상에 의한 전원외란 저감)

  • Chang, Chin-Young;Jin, Kang-Hwan;Kang, Jeong-Nam;Park, Dong-Kyu;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.206-211
    • /
    • 2010
  • Since high-speed train is a dynamic load in which electric power is externally supplied, contact loss between the catenary and pantograph occurs. This phenomena including vibrations generates frequently irregular arcs, which, in turn causes EMI. Thus it is very important to develop the approach to reduce arc phenomenon by contact loss, as speed of electric railway vehicle increases. In case of an electric railway vehicle using electrical power, compared with diesel rolling stock, Power Line Disturbance(PLD) such as harmonics, transient voltage and current, Electromagnetic Interference(EMI), and dummy signal injection etc usually occur. In this study, the dynamic characteristics of a contact wire and a pantograph suppling electrical power to high-speed train are investigated with an electrical response point. To implement power line disturbance induced by contact loss phenomenon for high speed train operation, a hardware simulator which considers contact loss between contact wire and pantograph as well as contact wire deviation is developed. It is confirmed by the experiments that contact loss effect is largely dependent on voltage conditions when the contact loss occurs. Also, a passive filter is designed to reduce power disturbance and the designed system is verified by experiment.

Transient Characteristic Study on Contact Loss of High Speed Electric Railway Using a Power Line Disturbance Simulator (전원외란 시뮬레이터를 이용한 고속전철 이선현상과도 특성 연구)

  • Kim, Jae-Moon;Kim, Yang-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.427-431
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI(Electromagnetic Interference), dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

Analysis of PCI Cable Effects in HEMP Conducted Disturbance (HEMP 전도성 방해 펄스 전류 주입(PCI) 케이블의 영향 분석)

  • Jang, Tae-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.772-780
    • /
    • 2013
  • The high-altitude electromagnetic pulse(HEMP) conducted environment and the HEMP radiated environment are established as the consequences of a high-altitude nuclear explosion. The IEC 61000-2-10, the international standard, defines the HEMP conducted environment. The IEC 61000-5-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. The IEC 61000-4-24 deals with methods for testing protective devices for HEMP conducted disturbance. The IEC 61000-4-24:1997 mainly describes the measurement method of small protective components. However, it does not provide the measurement method for a combination filter of a protective component and a filter which is widely used in recent. It is important to consider the characteristic of the measurement setup parameters like thickness and length of the cable and its height above ground plane etc. in establishing measurement setup because HEMP conducted disturbances include the frequency spectrum below 50 MHz. This paper deals with the optimized measurement method, considering the frequency spectrum of HEMP conducted disturbance, current waveform, and analyzing the effects of cables existing in the measurement setup.

Inductive Disturbance Reduction Method for Electric Railway (전기철도해서의 유도장해 경감책에 관한 연구)

  • Lee, Kyo-Sung;Kim, Do-Hun;Lee, Yong-Jae;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.369-371
    • /
    • 2002
  • The railway power feeding system is divided into AC power feeding system and DC power feeding system. In downtown area. DC power feeding system is used and AC power feeding system is used in intercity railway system. AC power feeding system raises a inductive disturbance that is divided into electrostatic induction and electromagnetic induction. Especially, it has a bad effect on communication lines. So inductive disturbance reduction method has been adopted in many system. In this paper, we deals with the inductive disturbance reduction method of railway power feeding system and of sides affected by inductive disturbance.

  • PDF

A Study on Performance Reduction Characteristics of Digital Wireless Communication by APD (APD 통계 모델에 의한 디지털 무선 통신 성능 저감 특성 연구)

  • Lim, Sung-Jin;Hur, Min-Ho;Kwon, Se-Woong;Yoon, Young-Joon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.8-12
    • /
    • 2003
  • To protect digital communications and broadcasting that are expected to be increasingly used at frequencies above 1GHz, there is a need to determine permissible disturbance limits for frequency bands above 1GHz according to indicates that better correlates with interference level in digital systems. The quality of digital communications is expressed in terms of bit error rate(BER) or throughput. In this regard, it has been reported that degradation of BER or throughput can be estimated from the amplitude probability distribution (APD) of disturbance amplitude. Therefore, if the APD can simply be measured with a high accuracy, APD will be an optimal index for the assessment of interference in digital communications. In this paper, we show that a measurement method using statistic model of APD has compatibility about performance reduction estimation of WLAN. And through approach of this inspection, we propose numeral models about interference effects of peak value and time rate of spurious.

  • PDF

The method for reducing the measurement errors of power line disturbance (전원단자 방해파 측정 오차의 개선 방법)

  • Shin, K.S.;Choi, S.H.;Lee, J.H.;Shin, H.S.;Kim, N.;Park, S.W.;Kim, J.S.
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.336-339
    • /
    • 2002
  • CISPR(Committee Internationale Special des Perturbations Radio Electriques) has proposed limits on the noises emitting from power lines and signal lines. But different measurement environment and different measurement methods are used in different countries. This difference causes much confusion in understanding the results measured by different test laboratories. In this paper, we measure EMI noise using the absorbing clamp method that takes short measurement time and is described in CISPR 13, 14-1, 16-2. We analyze the cause of the difference of measurement results.

  • PDF

Linear Quadratic Servo Design for Magnetic Levitation Systems Considering Disturbance Forces from Linear Synchronous Motor

  • Kim, Chang-Hyun;Ahn, Hanwoong;Lee, Ju;Lee, Hyungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.944-949
    • /
    • 2017
  • Recently, the demand of maglev systems in the manufacturing industry for LCD and OLED display panels, which are required to be very clean and possess vacuum systems, has been increasing due to their characteristics such as being non-contact, noise free and eco-friendly. However, it is still a challenge to simultaneously control both the propulsion and levitation for their interactive effect difficult to be exactly measured. In this paper, we proposed a new tuning method for controlling the magnetic levitation force robustly against the levitation disturbance caused by a propulsion system, based on LQ servo optimal control. The disturbance torque of the LSM propulsion system is calculated through FEM analysis in such a way that the LQ servo controller is determined in order to minimize the effect of the disturbance. The robust performance of the proposed LQ servo control method for the in-track type magnetic levitation systems is demonstrated via simulations and experiments.