• Title/Summary/Keyword: Electromagnetic shielding room

Search Result 26, Processing Time 0.026 seconds

Analysis of Electromagnetic Shielding Performance for a BiMODAL Tram using an Electromagnetic Concentration Index (전자파의 집중도를 이용한 바이모달 트램의 전자파 차폐 성능 분석)

  • Choi, Nak-Sun;Jeung, Gi-Woo;Kim, Nam-Kyung;Song, Myung-Kon;Lee, Kang-Won;Mok, Jai-Kyun;Kim, Dong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1378-1384
    • /
    • 2011
  • In this paper, the electromagnetic shielding performance of a BiMODAL Tram is investigated by means of an electromagnetic analysis tool, called HFSS. For the purposed of doing this, first, three-dimensional finite element modeling for the tram including electronic devices and engine room is carried out. Then, for quantitatively assessing the electromagnetic shielding performance of the tram's body, concentration indexes for electric field magnitude and time-average stored electric energy are introduced. From numerical results, it is inferred that the tram's body can protect the electronic devices and engine room against external electromagnetic waves from 30 MHz to 100 MHz.

Study on the Electromagnetic Shielding of Accessory Device without Electromagnetic Shielding Technology in the Magnetic Resonance Room (자기공명검사실 내 전자기파 차단이 이루어지지 않은 부속장치의 차폐에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.431-436
    • /
    • 2021
  • In this study, a new shielding method was applied to an accessory device that produces electromagnetic waves in the magnetic resonance room to prevent the generation of artifact caused by electromagnetic waves. The research method applied a new shielding made of metal plating fiber to patient surveillance CCTVs without shielding technology, and obtained and evaluated noise map when the power was not cut off and when the new shielding technology was applied without shutting down the CCTV. As a result of the study, it was found that there was at least one group with significant differences. Type I and type III belonged to group 1 while type II belonged to group 2 in the Post-hoc analysis, which meant blocking power of the CCTV and the applying new shielding technology were in the same group. In conclusion, if electromagnetic waves are generated due to additional accessories in the scanning room, the shielding material proposed in this study should be applied which enables the electric state become similar to type I, not generating noise, thereby preventing the artifacts caused by electromagnetic waves.

HEMP Analysis and Shielding Effectiveness (HEMP 분석과 방호 효율성)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.20-24
    • /
    • 2013
  • In this paper, we introduce a concept of HEMP systems and analyze a shielding effectiveness by varying placements of the antenna elements. Maxwell's equations for the high frequency of the EMP is represented in the LOS. In order to investigate the effects of electromagnetic attenuations, a shielding room was constructed and employed to obtain measured data. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

Electric Field Strength and Shielding Effectiveness Comparison According to the Size of Shielding Facility (방호 시설 크기에 따른 전계강도 및 차폐 효과 비교)

  • Kang, Ho-Jae;Huh, Chang-Su;Bang, Jeong-Ju;Choi, Jin-Su;Park, Woo-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.4
    • /
    • pp.221-225
    • /
    • 2014
  • In modern times, threat of high power electromagnetic wave is increasing. When the electrical grid and communication network are attacked by these high power electromagnetic wave, the whole infrastructure is paralyzed. To protect the infrastructure from these high power electromagnetic wave threat, the shielding facility that can block high power electromagnetic wave is constructed. Also shielding effectiveness evaluation about the constructed facility is important. But, because of space efficiency and saving of construction cost to construct the actual shielding facility, the shielding room wall is generally adjacent to exterior concrete structures. As space between shielding facility wall and concrete structures is very small, arranging the transmitting antenna exterior shielding facility is realistically difficult. Therefore, in this research, The shielding effectiveness measurement plan in the state of exterior narrow space of HEMP shielding facility is presented. And to apply this plan, The influence of shielding effectiveness according to the size of the shielding facility is analyzed.

A Study on the Electromagnetic Pulse Shielding Effect of Concrete Wall Sprayed with Cu-based Metal (Cu계 금속을 용사한 콘크리트 벽체의 전자파 차폐 성능에 관한 연구)

  • Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.18-19
    • /
    • 2020
  • The ElectroMagnetic Pulse (EMP) destroys social infrastructure at once and causes social chaos. However, currently major infrastructures are constructed of concrete that does not have electromagnetic shielding performance. In this study, using the arc metal spraying method is used to evaluate the shielding performance and construction performance of concrete. The electro-magnetic shielding effect is measured by fabricating a shielding room with reference to MIL-STD-188-125, and the construction performance is evaluated by measuring the adhesion strength of thin metal sprayed film-concrete. As a result of the study, when the metal spraying method is applied, the shielding effect is higher than that of the special electro-magnetic shielding concrete, and it is considered to be more economical than the existing metal plate (3~5 mm).

  • PDF

Measurements and Analysis of Electromagnetic Shielding Effectiveness of PDP TV Screen Filters (PDP TV Screen Filter의 Shielding Effectiveness 측정 및 분석)

  • Park, Gyu-Bok;Kim, Yoon-Jung;Kim, Young-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.47-53
    • /
    • 2003
  • Screen filter of PDP TV plays an important role in satisfying the EMI/EMC specifications. Two types of filters, the mesh type and the sputter type, are used in PDP TVs, and this paper presents measurement results of the shielding effectiveness (SE) in the frequency range from 50MHz to 1GHz. Two methods were used for the measurement, one using network analyzer (NA) in an open area test site(OATS), and the other using the screen room. The overall conclusion is that the shielding effectiveness of the screen filter is related to the surface resistance of the screen filter. The mesh type screen filters are superior to the sputter types in the shielding effectiveness, which is varying with the frequency.

  • PDF

Frequency Spectrum Analysis of Corona Discharge as Electrode Structures (전극 구조에 따른 코로나 방전의 주파수 스펙트럼 분석)

  • Jung, Kwang-Seok;Kim, Sun-Jae;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.118-118
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves which is generated by corona discharges as a basic study to develop a on-line diagnostic technique for power facilities installed in a closed-switchboard. Five types of electrode system were arranged to simulate corona discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. These results showed that the frequency spectrum of corona discharges exists widely in ranges from 30 to 1,000 [MHz].

  • PDF

Analysis of Design Elements in HEMP Systems (HEMP 시스템의 설계 요소 분석)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.6-11
    • /
    • 2013
  • In this paper, we explain the signal characteristics of HEMP and HEMP protection factors that affect the facilities are analyzed. We find the necessary elements of the physical facilities available for building. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

The Evaluation of the Characteristics of Electromagnetic Waves on CFRTP for Multimedia Instrument Applications (Multimedia 기기에의 적용을 위한 CFRTP에 대한 전자파 특성의 평가)

  • ;Ri-ichi Murakami
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.3
    • /
    • pp.254-263
    • /
    • 1997
  • As the communication and electronic industry develops, it is important to study the electromagnetic shielding effectiveness (SE) of carbon fiber (CF) reinforced thermal plastics (CFRTP) against the electromagnetic (EM) radiation. In this paper the shielding effectiveness of CFRTP was measured experimentally in an electromagnetic shielding room. The resin ma- terials used were PC, PP, PEI, PMMA and PA. Experiments were carried out by using a copper box and a monopole antenna with a spectrum analyzer. From the experimental results it was found that CF was a good candidate as an electromagnetic shielding material. The sheilding effectiveness was found to be increased in the composite as the number of laminated layers of CF was increased. As the minor damage increased, the SE increased due to increasing of the plane density, transmitting thickness and reflected angle of the CF. Other characteristics of the SE depended on the material used for the resin matrix, distance of the antennas and the noise frequency band.

  • PDF

A Study on Improvement of Method for Measuring the Shield Performance of Shielding Enclosures (전자파 차폐실의 차폐효과 측정방법 개선에 관한 연구)

  • Yeon, Jae-Sung;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.350-353
    • /
    • 2009
  • The shielding enclosure is very essential device to test the electromagnetic wave power generated by various RF equipments. Some standards for the shielding enclosures were established to test them in right method. Generally, There are IEEE-STD-299 and MIL-STD-285 and NSA-65-6 of the method for measuring the effectiveness of shielding enclosures, the IEEE-STD-299 combined MIL-STD-285 and NSA-65-6 about the method for measuring shielding effectiveness(SE) about 1969 years, but, the measurement point of 299 proposal is many points(including shielding wall, seam, coner beat, shielding door, etc) and demand long time of measurement. To improve SE test method for shielding enclosures was studied and suggested to develop a proper test procedure. First, we measure reference level as frequency range and H/V polarization, secondly, measure leakage point, and finally, measure shield effect and calculate SE. Our method has a merit of the less measurement point than IEEE-STD-299, and shorten time than 299, and define representation SE of shielding enclosure effectively.

  • PDF