• Title/Summary/Keyword: Endoscopic capsule

Search Result 11, Processing Time 0.038 seconds

Wideband Conformal Antenna for Endoscopic Capsule Application (캡슐 내시경에 응용 가능한 광대역 컨포멀 안테나)

  • Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.923-926
    • /
    • 2017
  • In this study, a novel wideband conformal thin antenna is presented for endoscopic capsule application at the 915 MHz Industrial, Scientific and Medical (ISM) band. The thickness of the antenna is only 0.2 mm which can be wrapped inside a capsule's inner wall. By cutting meandered slots on patch, open end slots on ground and utilizing long arm, the proposed antenna can obtain significant size reduction. The net volume of the proposed antenna including substrate and superstrate is only $37.4mm^3$ ($187mm^2$ surface area). This conformal antenna has shown good performance through simulation and measurement with maximum gain of -23 dBi and wide bandwidth from 137 MHz - 205 MHz depending on different environment. In addition, the effect of internal materials specially metallic battery is discussed briefly.

A method of assisting small intestine capsule endoscopic lesion examination using artificial neural network (인공신경망을 이용한 소장 캡슐 내시경 병변 검사 보조 방법)

  • Wang, Tae-su;Kim, Minyoung;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.2-5
    • /
    • 2022
  • Human organs in the body have a complex structure, and in particular, the small intestine is about 7m long, so endoscopy is not easy and the risk of endoscopy is high. Currently, the test is performed with a capsule endoscope, and the test time is very long. The doctor connects the removed storage device to the computer to store the patient's capsule endoscope image and reads it using a program, but the capsule endoscope test results in a long image length, which takes a lot of time to read. In addition, in the case of the small intestine, there are many curves due to villi, so the occlusion area or light and shade of the image are clearly visible during the examination, and there may be cases where lesions and abnormal signs are missed during the examination. In this paper, we provide a method of assisting small intestine capsule endoscopic lesion examination using artificial neural networks to shorten the doctor's image reading time and improve diagnostic reliability.

  • PDF

Class-Labeling Method for Designing a Deep Neural Network of Capsule Endoscopic Images Using a Lesion-Focused Knowledge Model

  • Park, Ye-Seul;Lee, Jung-Won
    • Journal of Information Processing Systems
    • /
    • v.16 no.1
    • /
    • pp.171-183
    • /
    • 2020
  • Capsule endoscopy is one of the increasingly demanded diagnostic methods among patients in recent years because of its ability to observe small intestine difficulties. It is often conducted for 12 to 14 hours, but significant frames constitute only 10% of whole frames. Thus, it has been designed to automatically acquire significant frames through deep learning. For example, studies to track the position of the capsule (stomach, small intestine, etc.) or to extract lesion-related information (polyps, etc.) have been conducted. However, although grouping or labeling the training images according to similar features can improve the performance of a learning model, various attributes (such as degree of wrinkles, presence of valves, etc.) are not considered in conventional approaches. Therefore, we propose a class-labeling method that can be used to design a learning model by constructing a knowledge model focused on main lesions defined in standard terminologies for capsule endoscopy (minimal standard terminology, capsule endoscopy structured terminology). This method enables the designing of a systematic learning model by labeling detailed classes through differentiation of similar characteristics.

Predictors of Small Bowel Transit Time for Capsule Endoscopy in Children with Inflammatory Bowel Disease

  • Itsuhiro Oka;Rie Funayama;Hirotaka Shimizu;Ichiro Takeuchi;Shuko Nojiri;Toshiaki Shimizu;Katsuhiro Arai
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.26 no.4
    • /
    • pp.181-192
    • /
    • 2023
  • Purpose: The development of assistive devices has allowed for the performance of capsule endoscopy in children. Anticipating the capsule's transit time could affect the efficacy of the investigation and potentially minimize the fasting period. This study determined the predictors of small bowel transit time for small-bowel capsule endoscopy in children and adolescents with inflammatory bowel disease. Methods: We retrospectively examined children and adolescents with inflammatory bowel disease who underwent capsule endoscopy by the age 18 at a Japanese tertiary care children's hospital. Small bowel transit time predictors were analyzed using multiple regression with explanatory variables. Results: Overall, 92 patients, aged 1-17 years, with inflammatory bowel disease (63 Crohn's disease and 29 ulcerative colitis cases) were examined for factors affecting small bowel transit time. In the simple regression analysis, diagnosis, age, height, weight, serum albumin, general anesthesia, and small intestine lesions were significantly associated with small bowel transit time. In the multiple regression analyses, serum albumin (partial regression coefficient: -58.9, p=0.008), general anesthesia (partial regression coefficient: 127, p<0.001), and small intestine lesions (partial regression coefficient: 30.1, p=0.037) showed significant associations with small bowel transit time. Conclusion: Hypoalbuminemia, the use of general anesthesia for endoscopic delivery of the capsule, and small intestine lesions appeared to be predictors of prolonged small bowel transit time in children and adolescents with inflammatory bowel disease. Expecting the finishing time may improve examination with a fasting period reduction, which benefits both patients and caregivers.

Mucosal Changes in the Small Intestines in Portal Hypertension: First Study Using the Pillcam SB3 Capsule Endoscopy System

  • Goenka, Mahesh Kumar;Shah, Bhavik Bharat;Rai, Vijay Kumar;Jajodia, Surabhi;Goenka, Usha
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.563-569
    • /
    • 2018
  • Background/Aims: To evaluate patients with portal hypertension (PH) of varied etiologies for portal hypertensive enteropathy (PHE) using the PillCam SB3 capsule endoscopy (CE) system. Methods: Consecutive patients with PH presenting with unexplained anemia and/or occult gastrointestinal bleeding were evaluated using the PillCam SB3 CE system. Abnormal findings were categorized as vascular or non-vascular. The patients with ongoing bleeding caused by PHE were treated. The correlation of the CE scores of PHE with the clinical, laboratory, and endoscopic features was determined. Results: Of the 43 patients included in the study, 41 (95.3%) showed PHE findings. These included varices (67.4%), red spots (60.5%), erythema (44.2%), villous edema (46.5%), telangiectasia (16.3%), and polyps (16.3%). The CE scores varied from 0 to 8 ($mean{\pm}standard$ deviation, $4.09{\pm}1.8$). Five patients (11.6%) showed evidence of ongoing or recent bleeding due to PHE. Three of these five patients underwent endotherapy, and one patient underwent radiological coil placement. Conclusions: The PillCam SB3 CE system revealed a high prevalence of PHE in the patients with PH. Using this system, evidence of bleeding due to PHE was found in a small but definite proportion of the patients.

Wireless capsule endoscopy Locomotion

  • Wang, Zhao;Lim, Eng Gee;Leach, Mark;Xia, Tianqi;Lee, Sanghyuk
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 2014
  • Wireless capsule endoscopy (WCE) was one of the most influential bio-medical electronic technologies to be developed at the beginning of the century. In comparison to traditional endoscopic diagnosis, this application is characterized as non-invasive and low-risk, thereby providing surgeons with a new alternative for inspecting the entire gastrointestinal (GI) track in a much more user friendly way. Apart from regular hardware upgrades, the frontier of WCE research basically lies in the miniaturization of the capsule and in active locomotion. In order to overcome the intrinsic drawback of current commercialized WCE products, which is that locomotion is generally a function of natural peristalsis, active locomotion is proposed as a series of strategies used to effectively navigate the device into different organs and conduct therapeutic functions within targeted human tissues. Reviews of several novel designs with respect to this aspect of research will be discussed in this article.

  • PDF

Retrospective study of postoperative intraocular pressure and complications in phacoemulsification combined with endoscopic cyclophotocoagulation and phacoemulsification alone in dogs

  • Sol Kim;Seonmi Kang;Youngseok Jeong;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Background: Long-term comparative data of phacoemulsification combined with endoscopic cyclophotocoagulation (phaco-ECP) versus phacoemulsification (phaco) alone in dogs are rare. Objectives: To investigate the effects of ECP on postoperative intraocular pressure (IOP) and complications after phaco in dogs with normal IOP. Methods: Medical records of IOP, conjunctival hyperemia, corneal edema, aqueous flare, posterior synechia, intraocular fibrin, and posterior capsule opacification (PCO) formation in 15 canine eyes that underwent phaco-ECP and 36 eyes that underwent phaco alone were evaluated retrospectively. ECP was applied when either the iridocorneal angle or the ciliary cleft was narrow or closed. Results: The IOP of the phaco-ECP group persisted within the normal range postoperatively. The phaco-ECP group had a shorter period of dorzolamide use than did the phaco group. PCO was formed earlier in the phaco-ECP group than in the phaco group. The phaco-ECP group showed more severe corneal edema than the phaco group at every follow-up visit. Posterior synechia was more severe in the phaco-ECP group than in the phaco group from two weeks until the last follow-up. Conclusions: Although ECP might cause more postoperative complications such as corneal edema and posterior synechia, it could effectively reduce the incidence of IOP increase after phaco in dogs with a high risk of postoperative glaucoma.

A Study on the Comparison of Learning Performance in Capsule Endoscopy by Generating of PSR-Weigted Image (폴립 가중치 영상 생성을 통한 캡슐내시경 영상의 학습 성능 비교 연구)

  • Lim, Changnam;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.6
    • /
    • pp.251-256
    • /
    • 2019
  • A capsule endoscopy is a medical device that can capture an entire digestive organ from the esophagus to the anus at one time. It produces a vast amount of images consisted of about 8~12 hours in length and more than 50,000 frames on a single examination. However, since the analysis of endoscopic images is performed manually by a medical imaging specialist, the automation requirements of the analysis are increasing to assist diagnosis of the disease in the image. Among them, this study focused on automatic detection of polyp images. A polyp is a protruding lesion that can be found in the gastrointestinal tract. In this paper, we propose a weighted-image generation method to enhance the polyp image learning by multi-scale analysis. It is a way to extract the suspicious region of the polyp through the multi-scale analysis and combine it with the original image to generate a weighted image, that can enhance the polyp image learning. We experimented with SVM and RF which is one of the machine learning methods for 452 pieces of collected data. The F1-score of detecting the polyp with only original images was 89.3%, but when combined with the weighted images generated by the proposed method, the F1-score was improved to about 93.1%.

Racemose Cysticercosis in the Cerebellar Hemisphere

  • Kim, Sang-Wook;Kim, Moon-Kyu;Oh, Sae-Moon;Park, Se-Hyuck
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.59-61
    • /
    • 2010
  • Neurocysticercosis is the most common parasitic disease of the central nervous system in humans, caused by infection of the larval stage of the pork tapeworm, Taenia solium. However, cerebellar involvement is rarely reported. We report of a case of racemose cysticercosis in the cerebellar hemisphere. A 44-year-old man presented with headache and dizziness. Magnetic resonance imaging showed hydrocephalus and an ill-defined, multicystic cerebellar mass with hypersignal on T2-weighted images, hyposignal on T1-weighted images and rim enhancement after gadolinium injection. The patient underwent endoscopic third ventriculostomy and the cyst resection was done through a craniotomy. In surgical field, cysts were conglomerated in a dense collagen capsule that were severely adherent to surrounding cerebellar tissue, and transparent cysts contained white, milky fluid. Histological findings confirmed the diagnosis of cysticercosis. He received antiparasitic therapy with praziquantel after surgery. Racemose cysticercosis is rare in the cerebellar hemisphere but neurocysticercosis should be taken into consideration as a differential diagnosis of multiple cystic lesions in the cerebellum.

Color Similarity-based Class Labeling Method for Deep Learning of Capsule Endoscopic Images (캡슐내시경 영상 딥러닝을 위한 색상 유사도 기반의 클래스 레이블링 기법)

  • Park, Ye-Seul;Hwang, Gyubon;Lee, Jung-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.749-752
    • /
    • 2017
  • 캡슐내시경 검사는 일반내시경으로는 관찰하기 힘든 소장 기관을 관찰할 수 있어 최근 환자들 사이에서 수요가 늘고 있는 검사 방법 중 하나이다. 이와 같은 캡슐내시경으로부터 병변에 대한 의료 정보가 획득될 수 있는데, 최근에는 캡슐내시경 영상의 학습을 통해 이를 자동으로 획득하려는 시도들이 이루어지고 있다. 예를 들면, 캡슐의 위치를 추적하기 위해 위장관의 개략적인 위치(위, 소장 등)를 파악하거나, 캡슐내시경 영상으로부터 관찰될 수 있는 병변(폴립 등)을 검출하기 위해 영상의 학습이 수행되고 있는 상황이다. 그러나 캡슐내시경의 방대한 영상 프레임 중에서 병변에 대한 영상은 극히 일부분이기 때문에, 기존 학습 영상의 클래스(레이블)는 다양한 병변에 대한 정의나 영상에서 확인될 수 있는 구체적인 속성이 고려되지 않는다. 따라서 본 논문에서는 캡슐내시경 관련 표준(MST, CEST)에서 정의하고 있는 주요 병변 정보에 대한 색상 유사도 분석을 통해, 출력층에서 활용될 수 있는 클래스 레이블링 기법을 제안한다. 제안하는 기법은 유사한 특성을 보이는 영상의 구분을 통해 세부적인 클래스 레이블링을 수행하여 체계적인 학습 모델의 설계를 가능케한다.