• Title/Summary/Keyword: Endurance Evaluation

Search Result 150, Processing Time 0.024 seconds

A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments (반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구)

  • 김동수;김광영;최병오;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF

Evaluation of Fatigue Endurance for an MTB Frame (산악용 자전거 프레임의 피로 내구성 평가)

  • Kim, Taek Young;Lee, Man Suk;Lim, Woong;Kim, Ho Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.1-5
    • /
    • 2013
  • In order to evaluate fatigue endurance for an MTB(mountain bike) frame, FEM(finite element method) analysis was performed. For evaluating the fatigue endurance of the MTB frame, the S-N data for Al-6061 fillet weldment were compared with the stress analysis results through FEM analysis of the frame. Three loading condition, pedalling, horizontal and vertical loading conditions were considered for fatigue endurance evaluation. Horizontal loading(+1200 N) condition was found to be the most severe to the frame. The maximum von Mises stress of the frame under horizontal loading(+1200 N) condition was determined 294 MPa through FEM analysis of the frame. Conclusively, on the basis of fatigue strength of 200 MPa at the number of cycles of 50,000, the MTB frame has an improper safety factor of approximately 0.25, suggesting that this frame needs reinforcement.

An evaluation on 100,000km endurance test for the Korean EMU (표준전동차 10만km 내구도 시험평가)

  • 정종덕;김원경;한석윤;이호용;안태기;한성호
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.336-343
    • /
    • 2002
  • This paper describes the result of endurance test on the Sangju test track. The purpose of the test is to prove the endurance of the Korean EMU for the commercial operation. Test conditions are more severe than actual operation on the commercial line. But endurance test come to an end well without severe problem. Hereafter, Korean EMU will be applied the quality certification of railroad supplies as a testing vehicle and their components will be applied in a new line.

  • PDF

Endurance Evaluation and Fatigue Property fo Axle Housing (Axle Housing의 내구성 판단과 피로특성)

  • Byeon, Hui-Mun;Lee, Sun-Bok
    • 한국기계연구소 소보
    • /
    • s.13
    • /
    • pp.3-13
    • /
    • 1984
  • Fatigue failure of axle housing could cause many injuries and much financial loss. This challenges the engineer to improve design decisions involving fatigue. Endurance evaluation of axle housing is great interest to auto-mobile manufacturers for the sake of safety and reliability. Axle housing is subjected to gross vehicle weight(G.V.W)as mean load and alternating load. Theoretical design diagram involving mean and alternating stresses is used for the evaluation of axle housing fatigue endurance with the equivalent stress of fatigue critical area on the axle housing. Four point bending fatigue tests on axle housing with constant amplitude loading at approximately R=0 were performed with 50 ton servohydraulic strucural fatigue testing machine developed at KIMM. Specimens were made with the same material STKM 13B as the axle housing and tested to obtain S_N data. Five specimens of STKM 13B were tested at 253.61 MPa and weibull distribution was obtained at the same stress level. Material data and structural data were compares and fatigue stress property factor and fatigue life property factor were obtained.

  • PDF

The Relationship between health related physical fitness and self-perceived health status (건강관련 체력과 주관적 건강인식에 관한 연구)

  • Kim, Jae-Hoon;Jin, Young-Soo;Park, Jung-Tae;Jee, Yong-Suk;Kim, Kun-Soo;Lee, Heun;Bae, Ki-Taec
    • Korean Journal of Health Education and Promotion
    • /
    • v.16 no.1
    • /
    • pp.83-100
    • /
    • 1999
  • Modern technology has lessened the physical demand of every activities. Thus, physical inactivity has led to a rise in ‘Hypokinetic diseases’. The prefix, hypo, means lack of and kinetic refers to movement. Individuals who do not exercise regularly are at greater risk of developing hypokinetic diseases such as coronary heart disease, hypertension, hyperlipidemia, obesity, musculoskeletal disease. Systematic exercise program defenses development of hypokinetic diseases. Exercise program bases on basic physical fitness test. The physical fitness evaluation is used to degree of Wellness of the individuals. It includes the evaluation of Health-Related Physical Fitness -musclular strength, muscular endurance, flexibility, cardiorespiratory endurance, body composition - and skill or sports related fitness -agility, balance, coordination, reaction time, speed. In present study, the authors investigated health-related physical fitness test result and questionnaire for 133 male and 71 female from Jannuary 16 to March 15, 1997. The purpose of this study is to observe relationship health related physical fitness and self-perceived health status. The results are as follows. 1. There were statistically significant differences in BMI, grip strength, back strength, muscular endurance, cardiorespiratory endurance, and flexibility between male and female subjects. Flexibility is higher in female than male subject, but Others are higher in male than female subjects. 2. There were statistically significant differences in grip strength, muscular endurance between 30s, 40s, and 50s group In both gender subjects, and In cardiorespiratoryendurance between the groups especially in Female subjects. 3. For male subjects, flexibilitywas measured lower in group who classified low level in self-perceived health status than group of others. Also, for female, subjects, Muscular endurance & flexibility were measured. 4. It was shown that grip strength, back strength, and muscular endurance were significantly lower in group who have chronic diseases than normal group for Male subjects. But, For female subjects, all the component were statistically insignificant results between normal and disease group. 5. Both male and female subjects, there were Positive correlation among grip strength, back strength, muscular endurance, cardiorespiratory endurance, and flexibility but, negative correlation for age. Therefore, health-related physical fitness is very important component for Heath Promotion & Wellness. Physical Fitness test is valuable test in health evaluation, health management and health promotion, so available for hospital, sports center, community health center, industrial field, school etc.

  • PDF

Durability evaluation for Korea type EMU's braking system (표준전동차 제동장치에 대한 내구도 평가(I))

  • 정종덕;최병기;한석윤;윤성철;이호용
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.131-138
    • /
    • 2001
  • This paper describes the result of endurance test of the brake system of the Korean EMU on the Sangju test track. The purpose of the test is to prove the endurance of brake system. Test conditions are more severe than actual operation on the commercial line. As of October, test result is good without severe problems. 100,000km of test operation will be continued by the end of this year to check the endurance of the brake system.

  • PDF

Evaluation of Fatigue Endurance for an Ultra-light-weight Inline Skate Frame (초경량 인라인 스케이트 프레임의 피로 내구성 평가)

  • Lee, Se-Yong;Kim, Ho-Kyung
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • In order to evaluate fatigue endurance for an ultra-light weight inline skate frame, FEM analysis was performed. Tensile properties and a S-N curve were determined through tensile and fatigue tests on a modified Al-7075+$S_c$ alloy. The yield and ultimate tensile strengths were 553.3 MPa and 705.5 MPa, respectively. The fatigue endurance limit of this alloy was 201.2 MPa. For evaluating the fatigue endurance of the inline skate frame, the S-N data were compared with the stress analysis results through FEM analysis of the frame. The maximum Von-Mises stress of the frame was determined 106 MPa through FEM analysis of the frame, assuming that the rider weight is 75 Kg. Conclusively, on the basis of fatigue limit, the inline skate frame has a safety factor of approximately 2.0.

Utilizing virtual vibration tests to optimize physical endurance tests

  • Kihm, Frederic
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.2
    • /
    • pp.239-249
    • /
    • 2018
  • Physical tests are performed at various stages of the development cycle of a product, from prototype validation to product qualification. Although costly, there are growing demands for qualification tests like endurance vibration testing to be more representative of the real world. At the same time there are growing demands to assess the durability of these items based on FEA simulation. In this paper, we will explain how to set up a CAE-based test and how to correlate the results with some physical measurements. Specific assumptions will be explained and some advantages of using virtual tests will be highlighted such as the reduction of the number of prototypes needed, investigations on failures, evaluation of the level of reliability via sensitivity analysis, evaluation of the margins are at the end of a successful test. This presentation will therefore focus on explaining and showing how virtual tests can enrich the exploitation of physical tests.

A Study for Development of Durability of the Subway Concrete Structure exposed to Choride Environment (염해 환경에 있는 지하철 콘크리트 구조물의 내구성 향상 대책수립에 관한 연구)

  • Lee Moo-Kwan;Kim Eun Kyum;Kim Dae Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1184-1189
    • /
    • 2005
  • Durability of concrete has been currently issued in the engineering societies and a large number of studies on the concrete corrosion in salty environment have been performed. The reinforcement corrosion, which is the primary reason of deterioration of the concrete structure exposed to chloride environment. is caused by the chloride ions infiltration owing to underground water seeping into the concrete. In this study. the endurance periods using the diffusion equation of the concrete specification have been evaluated on the concrete structures with different addictives for the brand new R/C subway structure exposed to seashore underground water. Furthermore. the guidance for proper use of the addictives and the reasonable thickness of concrete cover are derived for concrete mixing. From the result of the evaluation corresponding to salt damage for Inchon subway line I, the endurance periods of the ordinary Portlandcement concretes are represented as $42\~75$ years and fail to achieve the objective period of 100 years. However, the lower water-cement ratio expands the endurance periods and the blast furnace slag concrete with small quantity of the silica fume, which shows the best performance of corrosion resistance in this study, represents more than 170 years of the endurance period. Moreover, the case of use of blast furnace slag and fly ash together shows the endurance period of $134\~171$ years and it means that the result very satisfies the objective endurance period.

  • PDF

Evaluation of Fatigue Endurance for a Rocker Arm of Diesel engine (디젤 엔진 로커 암의 피로 내구성 평가)

  • Kim, Ho-Kyung;Yang, Kyoung-Tak;Kim, Hyun-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.1-6
    • /
    • 2007
  • In order to evaluate fatigue endurance for the rocker arm of a diesel engine, stress measurements were performed using the strain gages attached near the neck, where is one of the most critical region in the rocker arm, in variation of the engine speed. The fatigue life experiments were carried out on miniature specimens from the rocker arms. For evaluating the fatigue endurance of the rocker arm, the S-N data were compared with the stress analysis results through FEM analysis of the rocker arm. The effective stress of the neck region was determined 17.7MPa through FEM analysis of the rocker arm. Conclusively, on the basis of fatigue limit, the rocker arm has a safety factor of 2.8 or 3.4 from the stress measurement or FEM results, respectively.