• 제목/요약/키워드: Energy Performance Audit

검색결과 17건 처리시간 0.026초

공조시스템의 에너지진단 사례 (Case Studies of HVAC System through Energy audit)

  • 김두성;김천용;엄철준;송의
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.66-71
    • /
    • 2008
  • Energy audit was started in 2006 that Korea Government Policy for Energy saving. Who used over 2,000toe/yr(tons of oil equivalent) energy consumption has to perform Energy audit program of obligation every five years with auditing company. HANMI C&E as a company authorized by Government has diagnosed various type building. It shows four case studies of HVAC system in office building through Energy audit. This studies present efficient recommendation method for improving system performance.

  • PDF

The audit method of cooling energy performance in office building using the Simple Linear Regression Analysis Model

  • Park, Jin-Young;Kim, Seo-Hoon;Jang, Cheol-Young;Kim, Jong-Hun;Lee, Seung-Bok
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.13-20
    • /
    • 2015
  • Purpose: In order to upgrade the energy performance of existing building, energy audit stage should be implemented first because it is useful method to find where the problems occur and know how much time and cost consumption for retrofit. In overseas researches, three levels of audit is proposed whereas there are no standards for audit in Korea. Besides, most studies use dynamic simulation in detail like audit level 3 even though the level 2 can save time and cost than level 3. Thus, this paper focused on audit level 2 and proposed the audit method with the simple linear regression analysis model. Method: Two parameters were considered for the simple regression analysis, which were the monthly electric use and the mean outdoor temperature data. The former is a dependent variable and the latter is a independent variable, and the building's energy performance profile was estimated from the regression analysis method. In this analysis, we found the abnormal point in cooling season and the more detailed analysis were conducted about the three heat source equipments. Result: Comparing with real and predicted models, the total consumption of predicted model was higher than real value as 23,608 kWh but it was the results that was reflected the compulsory control in 2013. Consequently, it was analyzed that the revised model could save the cooling energy as well as reduce peak electric use than before.

민감도 분석을 통한 기존건축물의 에너지성능 진단항목 선별 (Selecting of the Energy Performance Diagnosis Items through the Sensitivity Analysis of Existing Buildings)

  • 공동석;장용성;허정호
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.354-361
    • /
    • 2015
  • The building energy audit is an important process when collecting basic information for improving the energy performance of existing buildings. Audit parameters should be associated with the energy performance of the building. Such audit parameters will vary according to an individual building's characteristics and energy consumption patterns, but most building energy audits are performed in the same way. The sensitivity analysis (SA) is a statistical method to quantify the correlation between inputs and outputs that can determine which input is influential to which output. Therefore, an SA can identify influential parameters when applied to building energy analysis. In this paper, we adopted the Morris method to identify building energy audit parameters and performed a Monte Carlo simulation for uncertainty analysis. As a result, this method was able to identify an influential parameter for building energy audits and reduce uncertainty in energy consumption in buildings.

에너지진단 우수 사례소개 (Case Studies of best practices through Energy audit)

  • 엄철준;송의;김천용;김두성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.505-510
    • /
    • 2008
  • Improving energy efficiency is the important thing of energy saving strategies that was shown up result of IEA meeting and the G8 Summit. Energy audit was started in 2006 that Korea government policy for improving energy efficiency. Who used over 2,000toe/yr(tons of oil equivalent per year) energy consumption has to perform energy audit program of obligation every five years with auditing company. HANMI C&E as a company authorized by Government has diagnosed various type building. This case studies are chosen to best practices by KEMCO. This studies present efficient recommendation methods for improving system performance.

  • PDF

品質經營體制의 有效性 評價를 위한 效率的인 品質監査의 遂行方案 (Quality Audit for Measuring the Effectiveness of Quality Management Systems)

  • 남지희;김관현;조문성;임남진
    • 품질경영학회지
    • /
    • 제28권2호
    • /
    • pp.252-263
    • /
    • 2000
  • The purport of quality assurance audit and its procedures as specified in ISO 9000 have been reviewed. The principles and techniques for interview, documentation of the results and quality trend analysis were discussed. The practical techniques for the performance of quality audit for measuring the effectiveness of quality management systems were suggested.

  • PDF

Proficiency Test for the Dosimetry Audit Service Provider

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.72-79
    • /
    • 2022
  • Purpose: The proficiency test was conducted to assess the performance of the dosimetry audit service provider in the readout practice of the dose delivered to patients in medical institutions. Methods: A certain amount of the absorbed dose to water for the high-energy X-ray from the medical linear accelerator (LINAC) installed in the Korea Research Institute of Standards and Science (KRISS) was delivered to the postal dose audit package given by the dosimetry audit service provider, in which the radio-photoluminescence (RPL) glass dosimeters were mounted. The dosimetry audit service provider read the RPL glass dosimeters and sent the readout dose value with its uncertainty to KRISS. The performance of the dosimetry audit service provider was evaluated based on the En number given in ISO/IEC 17043:2010. Results: The evaluated En number was -0.954. Based on the ISO/IEC 17043, the performance of the dosimetry service provider is "satisfactory." Conclusions: As part of the conformity assessment, the KRISS performed the proficiency test over the postal dose audit practice run by the dosimetry audit service provider. The proficiency test is in line with confirming the traceability of the medical institutions to the primary standard of absorbed dose to the water of the KRISS and ensuring the confidence of the dosimetry audit service provider.

건물에너지 성능 평가를 위한 효과적 기상자료 선정에 관한 연구 (Assessment of Insolation Data in Korea for Building Energy Performance Assessment)

  • 김기세;김창범;박준언;윤종호;이의준;송인춘
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.31-39
    • /
    • 1998
  • 성공적인 건물에너지 진단을 위한 주요한 인자중의 하나는 올바른 기상화일의 선정에 있다고 할 수 있다. 따라서 본 연구에서는 건물의 에너지진단을 위한 프로그램의 기상화일을 제공하기 위해 국내 주요 6개도시의 약 30년간의 Raw Data DB를 구축하였으며, 이를 활용하여 사용자로 하여금 필요한 기상요소만을 선택하여 출력할 수 있도록 구성한 기상요소 선택프로그램 "KWDP version 1.0"을 개발하였다. 또한 누락된 기상요소를 생성할 수 있는 DOE2.1E용 기상데이터 생성 프로그램인 Wmake.exe 프로그램을 개발하였고, 에너지진단을 위한 시뮬레이션의 결과에 신뢰도를 높일 수 있는 기상데이터의 선정방법을 제시하였다.

  • PDF

The Relationship Between Three-Level Review System and Audit Quality: Empirical Evidence from China

  • TANG, Kai;YAN, Sibei;BAE, Khee Su
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권5호
    • /
    • pp.135-145
    • /
    • 2022
  • To improve audit quality, certain Chinese auditing firms have added a third-level review by an additional signing auditor to the general evaluation by a signing auditor team consisting of an engagement auditor and a partner. Nonetheless, our research-based on 36,033 firm-year observations from 2004 to 2019 reveals that compared to the general review system, auditor teams under the three-level review system are less likely to issue modified audit opinions when abnormal financial conditions arise. This finding suggests that, while larger auditor teams' knowledge, experience, and information advantages can theoretically sharpen their judgment, their performance is more susceptible to interference from divergent opinions, the diffusion of responsibility, and lower energy invested by individual auditors, ultimately impairing their judgment regarding the audited enterprises' abnormal financial conditions. That is, the three-level review system, which aims to improve audit quality, actually worsens audit quality. This conclusion remains valid after the problems of heteroscedasticity and endogeneity are addressed by using firm-level cluster robust standard errors and two-stage regression. We hope that our research will draw the attention of auditing firms, prompting them to reconsider the rationality of the three-level review system.

화학산업에서의 안전성능지수 개발에 관한 연구 (A Study on the Development of Safety Performance Index in Chemical Industry)

  • 강미진;이영근;권혁면
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.57-61
    • /
    • 2008
  • In order to maintain the continual safety management in a company, it needs to evaluate and monitor its implementation of safety management. Because the number of major-accidents is not an effective method of indicating company's safety performance, various efforts to develop more reasonable indicators have been made in world wide. After Korean government has legally required the PSM report, PSM compliance audit has been developed and made by the authorities concerned since 2005. However, this audit consists of complicate procedures difficult to utilize as companies' own audit program and corresponds to only a conformity check that confirms whether the PSM be operated and maintained properly. So a new index by which to measure easily the level of safety performance and self-monitor the implementation of safety management is needed. We have studied a new method that may quantitatively evaluate the performance of safety management by investigating application cases in foreign countries and doing the domestic survey of lots of companies subject to PSM regulation in Korea. This study proposes three of safety performance indices(SPI) together with the several prerequisite preconditions and the timing for application of each index. Although the first draft of SPI needs further legal support, it might help to evaluate every company's safety level. The second draft of SPI is a voluntarily evaluating method based on web-site online program. The last draft of SPI consists of a series of simple questions about 12 elements of PSM. Also each of 3 indices has differences in evaluation methodology and application area and, therefore, they may be used concurrently.

In-Situ Diagnosis of Vapor-Compressed Chiller Performance for Energy Saving

  • Shin Younggy;Kim Youngil;Moon Guee-Won;Choi Seok-Weon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1670-1681
    • /
    • 2005
  • In-situ diagnosis of chiller performance is an essential step for energy saving business. The main purpose of the in-situ diagnosis is to predict the performance of a target chiller. Many models based on thermodynamics have been proposed for the purpose. However, they have to be modified from chiller to chiller and require profound knowledge of thermodynamics and heat transfer. This study focuses on developing an easy-to-use diagnostic technique that is based on adaptive neuro-fuzzy inference system (ANFIS). The effect of sample data distribution on training the ANFIS is investigated. It is found that the data sampling over 10 days during summer results in a reliable ANFIS whose performance prediction error is within measurement errors. The reliable ANFIS makes it possible to prepare an energy audit and suggest an energy saving plan based on the diagnosed chilled water supply system.