• 제목/요약/키워드: Energy metering

검색결과 106건 처리시간 0.049초

전기철도차량 운행에너지 실시간 계측을 위한 에너지 미터링 장치 개발에 관한 연구 (A Study on the Development of a Real-time Energy Metering Device for Electric Railway Vehicles)

  • 김용기;한문섭;천윤영;배창한;윤병주
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.689-694
    • /
    • 2016
  • The objective of this study is to identify the requirements for a energy metering device and develop a real-time energy metering device for measuring energy (electricity) consumption of the electric railway vehicle during its operation. The study also evaluated the performance of the AC voltage sensor, current sensor, and data meter for the device and performed EMC tests such as surge and EFT (Burst). The performance tests showed that the percent errors of the AC voltage sensor and current sensor were ${\leq}0.1%$, and ${\leq}0.5%$ under 10~127V, and 10~250A, respectively. The result of surge and EFT (Burst) tests also indicated that the device had no malfunction in any wave (combination and ring waves) under the treat level with 2kV. The result of the field test also confirmed that the device had no malfunction in data metering.

사무소 건물의 에너지 미터링 시스템 구축에 관한 사례연구 (A case study for installing of Energy Metering Systems in an Office Building)

  • 한혜심;이나은;이진숙;정학근;장철용
    • KIEAE Journal
    • /
    • 제13권5호
    • /
    • pp.51-57
    • /
    • 2013
  • Energy saving starts by knowing how much energy is being consumed. A building factor is easier than any other things in energy saving. Since, especially, it is closely connected with user's space-use-patterns and manager's utility-operation-style. An energy metering system lets building users know about energy consumption pattern in buildings and measure energy in real time. Development and materialization of metering systems need more careful plans, so that they depend on a demand of individual facilities and available infrastructures they used to use. But, so far, there is no guidelines how to install metering systems. This paper suggested how to install meters and researched a method for how to analyze by using metered data. For that, Green Building in KIER is used as a test bed. As the results, nevertheless the smallest number of meters is basically one for the whole building energy measuring, it is too limited in analysis. So we needed to add the sort of fuel and utility types and found that it depends on all cases. For this reasons, a guideline should be created in order to install meters as soon as possible. It would be suggest a way to save more energy in building factor.

Advanced Metering Infrastructure를 이용한 Consumer Portal 개발 (A Development on Consumer Portal System based on Advanced Metering Infrastructure)

  • 진성일;정남준;유인협;김선익;고종민
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1903-1909
    • /
    • 2007
  • As the electric power industry has been revolutionarily transformed such that the distributed energy resources have been interconnected with power systems and a variety of energy service providers have been appeared, the need of Consumer Energy Portal as a core of two-way communication and service infrastructure between power suppliers and consumers has been gradually increased. Consumer Energy Portal can be thought of as a combination of hardware and software enabling two-way communication between energy service providers and equipment within the consumers' premises or a physical and logical link between consumers' in-building networks and wide-area access networks. In other words, Consumer Energy Portal can make the way the power industry has been traditionally operated the web-based way, enabling two-way interactions between energy service providers and consumers and mutual networking between end users' equipment. Thus, Consumer Energy Portal can be a kind of Service portal that provides new value-added services and efficient power operations that in the past. In this paper, for ESPs' integrated resources management, demand side management and value-added service provision, we have established the two-way access network that can gather real-time metering data using ZigBee technology and control physically networked equipment.

Independent Metering Valve: A Review of Advances in Hydraulic Machinery

  • Nguyen, Thanh Ha;Do, Tri Cuong;Ahn, Kyoung Kwan
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.54-71
    • /
    • 2020
  • In light of the environmental challenges, energy-saving strategies are currently under investigation in the construction industry. This paper focuses on the energy-saving method used in the hydraulic system based on independent metering (IM) technologies, which can overcome the lost energy at the main control valve of the conventional electrohydraulic servo system. By scientifically arranging the proportional valves, the IM system can individually control the flow rate of the inlet and the outlet ports of the actuators. In addition, the IMV system can be used to effectively regenerate energy under different operating modes, thereby saving more energy than conventional hydraulic systems. Therefore, the IMV system has a great potential to improve the energy efficiency of hydraulic machinery. The overall IMV system, including the configuration, proportional valve, operation mode, and the control strategy is introduced via state-of-the-art hydraulic technologies. Finally, the challenges of IM systems are discussed to provide researchers with directions for future development.

지열원 열펌프 시스템의 에너지 생산량 모니터링 신뢰도 향상 방안 연구 (A Study on the Monitoring Methods for Energy Production in Ground Source Heat Pump System)

  • 강신형;이광호;도성록;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.10-16
    • /
    • 2019
  • In this study, the present regulation of heat metering for the ground source heat pump was investigated. The ground source heat pump has been adopting the heat metering system used in the district heating system for estimating the heating and cooling energy production amount. The accuracy of the present heat metering systems for a water to water ground source heat pump is low, because the system for district heating has a relatively high temperature range comparing with the ground source heat pump operating conditions. Even though the heat amount for the building side should be measured, the heat absorption and extraction amount from or to the ground was measured for the water to air ground source heat pump due to the difficulty of estimating the air side heating and cooling capacity in the present regulation. It is highly recommended to validate the heat metering system to have reliability for the ground source heat pump and develop the system to be applicable water to air ground source heat pump.

분전반 전력관리용 지능형 계측 제어 시스템 개발 (A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel)

  • 박병철;박재성;송성근;신중린
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

첨단 검침 인프라에서 에너지 효율을 위한 기기 할당 방안 (The Device Allocation Method for Energy Efficiency in Advanced Metering Infrastructures)

  • 정성민
    • 디지털산업정보학회논문지
    • /
    • 제16권1호
    • /
    • pp.33-39
    • /
    • 2020
  • A smart grid is a next-generation power grid that can improve energy efficiency by applying information and communication technology to the general power grid. The smart grid makes it possible to exchange information about electricity production and consumption between electricity providers and consumers in real-time. Advanced metering infrastructure (AMI) is the core technology of the smart grid. The AMI provides two-way communication by installing a modem in an existing digital meter and typically include smart meters, data collection units, and meter data management systems. Because the AMI requires data collection units to control multiple smart meters, it is essential to ensure network availability under heavy network loads. If the load on the work done by the data collection unit is high, it is necessary to allocation new data collection units to ensure availability and improve energy efficiency. In this paper, we discuss the allocation scheme of data collection units for the energy efficiency of the AMI.

수소충전소 계량 정확도 향상을 위한 거래량 산출 모델 연구 (A Study on the Transaction Volume Calculation model for Improving the Measurement Accuracy of Hydrogen Fuelling Station)

  • 최진영;이화영;임상식;이재훈
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.692-698
    • /
    • 2022
  • With the expansion of domestic hydrogen fuelling station infrastructure, it is necessary to secure reliability among hydrogen traders, and for this, technology to accurately measure hydrogen is important. In this study, 4 types of hydrogen trading volume calculation models (model 1-4) were presented to improve the accuracy of the hydrogen trading volume. In order to obtain the reference value of model 4, and experiment was conducted using a flow rate measurement equipment, and the error rate of the calculated value for each model was compared and analyzed. As a result, model 1 had the lowest metering accuracy, model 2 had the second highest metering accuracy and model 3 had the highest metering accuracy until a certain point. But after the point, model 2 had the highest metering accuracy and model 3 had the second metering accuracy.

전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링 (Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module)

  • 정득일;손영대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

스마트계량시스템을 활용한 수요관리자원에 대한 가치평가연구 (A Economic Evaluation for Demand-Side Resource using Smart Metering System)

  • 임상국;신희상;조성민;이희태;윤용태;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권2호
    • /
    • pp.44-50
    • /
    • 2010
  • 에너지관련 자원가격의 급등으로 전력생산비용이 증가하여 세계 여러 나라의 전력회사들이 재정적인 어려움에 직면하고 있다. 이러한 전력 생산비용과 판매가격의 왜곡을 해결하기 위한 다양한 방법이 모색되고 있다. 본 논문에서는 제안된 스마트계량시스템은 전력 소비자의 전력사용 정보제공을 통한 소비패턴을 변화시켜 전력에너지절감을 유도하는 효과가 있는 것으로 알려져 있다. 우리나라에서는 스마트계량시스템의 보급을 위해 2008년도 실효성 검증을 위한 실증연구 과제를 추진하였으며, 본 논문에서는 그 결과를 바탕으로 스마트계량시스템 보급에 따른 잠재적 이득과 캘리포니아 테스트를 통한 가치평가 결과를 제시하였다.