• Title/Summary/Keyword: Environmental Control System

Search Result 2,940, Processing Time 0.033 seconds

Development of Environmental Control Systems for Windowless Pig-housing (I) - Assessment of Control Performance - (무창돈사의 환경제어 시스템 개발 (I) - 제어성능의 평가 -)

  • 장홍희;장동일;임영일
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.415-424
    • /
    • 1999
  • This study was conducted to assess performances of the developed environmental control systems under various seasons of Korea. In all trials for the environmental control systems, the manure pit ventilation system in the windowless pig-housing with partly slatted floor was used. Consequently, under all seasons of Korea, the complex environmental control systems could comfortably maintain the indoor temperature (14.8~27.2$^{\circ}C$) , concentrations of noxious gases (CO2 gas : 631~1,874ppm, NH3 gas : 0.3~3.2ppm), air velocity (0.11~0.23m/s), air movement, and so on. Therefore, the performances of the complex environmental control systems were evaluated as proper as the intended.

  • PDF

Numerical Analysis and Experiment of Environmental Control Cell for Ultra-nano Precision Machine (초정밀 가공기를 위한 환경 제어용 셀에 관한 실험 및 해석적 연구)

  • Oh, S.J.;Kim, C.S.;Cho, J.H.;Kim, D.Y.;Seo, T.B.;Ro, S.K.;Park, J.K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.5
    • /
    • pp.824-830
    • /
    • 2013
  • In ultra-precision machining, the inside temperature should be controlled precisely. The important factors are environmental conditions (outside temperature, humidity) and temperature conditions (cutting heat, spindle heat). Thus, in this study, an environmental control cell for the ultra-precision machine that could control the inside temperature and minimize effects of the surrounding environment to achieve a thermal deformation of less than 400nm of a specimen was designed and verified through C.F.D. Further, a method that could control the temperature precisely by using a blower, heat exchanger and heater was evaluated. As a result, this study established a C.F.D technic for the environmental control cell, and the specimen temperature was controlled to be within $17.465{\pm}0.055^{\circ}C$.

Study on Effect of Business Environment and Result by Excellence Environmental Management Strategic System (초일류 환경경영시스템 전략이 기업 환경경영 성과에 미치는 영향)

  • 임병율;이상복
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2004.04a
    • /
    • pp.142-147
    • /
    • 2004
  • Until now, our country environment management system are operated by past control system, but which system have many restrict to be familiar environment. Nowadays, many company try proactive control environment management system, specially by ISO 14001 system. In this paper we propose new Excellence Environmental Management Strategic which are compounded with Malcom Baldridge National Quality Award and ISO 14001.

  • PDF

Establishing the Methodology of Economic Analysis to Take into Account Opportunistic Valuation for a Radio Communication & Train Control System (철도무선신호제어시스템 실용화의 기회가치성을 고려한 경제성분석 체계 정립 -일반 및 고속철도용 무선 및 제어시스템 실용화 사례를 중심으로-)

  • Cho, Shin-hyung;Seo, Young-hyun;Kho, Seung-young;Rhee, Sung-mo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.373-379
    • /
    • 2016
  • Development of a train wireless signal control system using LTE-R technology is expected to have a great ripple effect to the existing signal control market. To make inroads into the international market, it is an urgent issue to practicalize the train wireless signal control system. Because it will require a huge budget to commercialize the wireless signal control system, it is necessary to analyze the feasibility beforehand, with a consideration of the domestic and foreign marketability and the impact on related industries. This study investigated the effect of the practicalization of train control system on future railway and national industrial sectors. We suggested the establishment of a framework for economic feasibility analysis, one that can provide criteria for opportunistic valuation. We also verified this framework through case analysis.

A study on the model follwing adaptive control system of industrial robtoic manipulatior for factory automation

  • Han, Sung-Hyun;Lee, Man-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.993-998
    • /
    • 1988
  • Adaptive control system has evolved as an attempt to avoid degradation of the dynamic performance of a control system when environmental variations occurs. While the feedback control system is oriented toward the elimination of the effect of state perturbations, the adaptive control system is oriented toward the elimination of the effect of structural perturbation, upon the performances of the control system. The model reference adaptive controller is utilized in velocity loop controller for positioning and tracking is designed based on the linear decoupled dynamics.

  • PDF

A Review on the Qualification System of the Environmental field : Current Status and New Directions (환경분야 자격제도 운영현황과 발전 방안 연구)

  • 박종성;이무춘
    • Hwankyungkyoyuk
    • /
    • v.14 no.1
    • /
    • pp.43-55
    • /
    • 2001
  • The purpose of this study was to review the current status and problems of the national qualification system in the Environmental field focusing on deficiencies of the regulatory system and qualities of environmental professional including the Environmental control Professional Engineer, Environmental Engineer, Environmental Industrial Engineer and Environmental field. An overview of the environmental field, its current status, domestic qualification items and training conditions in environment-related areas, laws of environmental field, and data of the job analysis were reviewed. The concrete and extensive development plans for the qualification system of the Environmental field are as follows: First of all, a job analysis should be made of on the introduction of new systems or policy modification to reflect technical changes and national policies about the environmental field in the qualification exam. Second, it is essential to prepare policies that are suitable for the qualification system in the Environmental field and that improve its effectiveness. Third, the appropriate policy measures should be taken in order to elevate the social standing of Environmental field qualification holders.

  • PDF

Application of X-Y Dissociation of Mice as the in vivo Assaying System for Environmental Mutagens (Mouse 제 1정모세포에서의 X-Y 염색체 조기 분리;in vivo 환경성 변이원 검출계로서의 응용 가능성)

  • 최영현;권용원;최병태;조운복;이원호
    • Toxicological Research
    • /
    • v.11 no.1
    • /
    • pp.51-55
    • /
    • 1995
  • The present experiment was carried out to investigate whether X and Y chromosome dissociation in the primary spermatocytes of mice can be used as an in vivo assaying system that detect environmental mutagens. For this purpose, alkylating agents (EMS, MMS and MMC), which are strong mutagens, were administered to ICR male mice 12-15 weeks old. The mean frequencies of previously dissociated X-Y chromosomes and autosomes of the control group were 7.34-7.45% and 0.92-1.04%, respectively. The frequencies of X-Y dissociation in the mutagen-treated groups with 10.0 mM EMS and 5.0 mM MMS were about 3.3-4.6 times higher than that in the control group, but there were no significant differences in dissociation of autosomes in both the control and the mutagen-treated groups. These results suggest that X-Y dissociation in the primary spermatocytes of mice can be used as an in vivo short-term assaying system for environmental mutagens.

  • PDF

Merging of Satellite Remote Sensing and Environmental Stress Model for Ensuring Marine Safety

  • Yang, Chan-Su;Park, Young-Soo
    • Journal of Navigation and Port Research
    • /
    • v.27 no.6
    • /
    • pp.645-652
    • /
    • 2003
  • A virtual vessel traffic control system is introduced to contribute to prevent a marine accident such as collision and stranding from happening. Existing VTS has its limit. The virtual vessel traffic control system consists of both data acquisition by satellite remote sensing and a simulation of traffic environment stress based on the satellite data, remotely sensed data And it could be used to provide timely and detailed information about the marine safety, including the location, speed and direction of ships, and help us operate vessels safely and efficiently. If environmental stress values are simulated for the ship information derived from satellite data, proper actions can be taken to prevent accidents. Since optical sensor has a high spatial resolution, JERS satellite data are used to track ships and extract their information. We present an algorithm of automatic identification of ship size and velocity. It lastly is shown that based on ship information extracted from JERS data, a qualitative evaluation method of environmental stress is introduced.

Control of Automated Greenhouse Based on a PC (PC 기반 자동화 시설 하우스 제어)

  • 김기환
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.9
    • /
    • pp.644-649
    • /
    • 2004
  • To control a greenhouse is to control environmental parameters in greenhouse. Controlled environments may be as simple as saran-covered shade houses or as complex as growth chambers. Although greenhouses are probably the most common example of a controlled environment used in agricultural/horticultural production, the type of controlled environment or system that is needed depends upon the climate, time of year, crops being produced and the environmental parameters that must be controlled. In this contribution puts emphasis on construction of automatic-controlled greenhouse system by personal computer.

Compressor Control of a Multi-type AIr Conditioning System (멀티형 냉방시스템의 압축기 제어)

  • 한도영;권형진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.780-786
    • /
    • 2001
  • For the compressor speed control of a multi-type air conditioning system, a fuzzy control algorithm was developed. The sum of zone temperature errors and its derivative were used as input variables, and the compressor speed was selected as the output variable. To test the effectiveness of the control algorithm, one outdoor environmental chamber and four indoor environmental chambers were used. In the chambers the zone temperature step change test and the indoor unit change over test were performed. Test results showed that, for the control of compressor speed, the fuzzy control algorithm was more effective than the conventional proportional control algorithm for the energy conservation.

  • PDF