• Title/Summary/Keyword: Epoxy putty

Search Result 15, Processing Time 0.026 seconds

Application of epoxy putty external skeletal fixator for stabilization of tarsocrural arthrodesis in small dogs and cats

  • Moon, Je-Sung;Lee, June-Sub;Han, Hyun-Jung
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.4
    • /
    • pp.187-194
    • /
    • 2020
  • Two small-breed dogs and two cats, with an average body weight of 4.88 kg (range: 4.3-5.5 kg), suffered hindlimb lameness due to luxation with or without fractures of the tarsocrural joint. These patients underwent tarsocrural arthrodesis with epoxy putty external skeletal fixator. The animals' skins were incised minimally, and the articular cartilage of the tarsocrural joint was removed, followed by autogenous cancellous bone grafting. Epoxy putty and positive Centerface®, pins with diameters 1.2 mm and 2.0 mm, were used for connecting bar and as a full pin fixation, respectively. All the patients regained the ability to bear weight on the affected limb within 3-7 days and resumed a normal gait within 9-15 weeks. The external skeletal fixator frame was removed within 13-17 weeks without major complications. Tarsocrural arthrodesis using epoxy putty external skeletal fixator resulted in excellent outcomes without severe postoperative complications in this study. Epoxy putty external skeletal fixator can be a valuable surgical option for tarsocrural arthrodesis in patients weighing less than 5.5 kg.

Study on the Development of Putty According to Epoxy Resin Hardener (Epoxy 수지 경화제에 따른 Putty 개발에 관한 연구)

  • Oh, Seung-Jun;Cheong, Da-Som;Park, Gi-Jung;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.31 no.2
    • /
    • pp.105-114
    • /
    • 2015
  • In this study, an advanced epoxy putty which was as a multi-purpose restoration material being used to restore missing parts in the artifact preservation treatment process was developed. For the purpose of addressing the issues including the workability issue resulting from high strength, the drooping issue resulting from long hardening time during work process and the issue of contaminating the surface of artifact resulting from stained material on tools or gloves, a property comparison was conducted with existing materials to examine the properties of restoration materials in the form of epoxy putty currently being frequently used. For the purpose of addressing the issues of existing materials and allowing the developed epoxy putty to have similar properties, two types of hardeners with different properties were selected to conduct property experiments. As for the hardeners, mercaptan type hardener and aliphatic amine type hardeners in the total of two types were selected for the development. The result showed that the two types were both in the form of paste and their hardening time of 5-10 minutes were about 3-10 times shorter than that of existing materials, thereby improving the work convenience. In terms of abrasion rate to increase workability, it was improved by about 3 times to allow effective and convenient use. As for the issue of contaminating the artifact surface during the process, white micro-balloon was added as filler to address the issue to reduce the oil ingredient to develop multi-purpose restoration material with low shrinkage & high workability in coloring, light weight and cutting force.

A study on the development and the physical properties of Epoxy Putty for earthenware restoration (토기 복원용 Epoxy Putty 개발 및 물성에 관한 연구)

  • Bae, Jin Soo;Cheong, Da Som;Kim, Woo Hyun;Kang, Seok In;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.30 no.1
    • /
    • pp.103-109
    • /
    • 2014
  • This study aimed to develop materials to compensate for problems of restoration for lost parts and material problems in the conservation treatment. First, there are several problems with existing materials as follows: secondary damage due to the high shrinkage rate and low adhesive strength, sense of difference due to the severe yellowing, remelting due to irreversibility of materials, processability due to the high strength, sag due to the prolonged setting time in the work process and surface contamination of artifacts due to tools or gloves. In order to solve these problems, this study set developmental goals after understanding the types and physical properties based on epoxy resin among the currently used restoration materials of pottery and earthenware. The developed epoxy resin is epoxy putty, which is cured within 5 minutes, for earthenware restoration. In the earthenware restoration method, the epoxy putty enhanced the workability by quickly curing in paste form and compensated disadvantages such as surface contamination. In addition, the use of white micro-balloon for the epoxy stock solution made coloring easier and weight lighter, and a restoration material with low shrinkage and superior processability was developed.

Study on the Development and Property of Epoxy Putty with Excellent Low Shrinkage and Cutting Force Using Mercaptan Type and Diamine Type (Mercaptan계와 Diamine계를 이용한 저수축·절삭력이 우수한 Epoxy Putty의 개발 및 물성에 관한 연구)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Adhesion and Interface
    • /
    • v.16 no.4
    • /
    • pp.137-145
    • /
    • 2015
  • This study aimed to develop epoxy putty as a multi-purpose connection and restoration material that can be used for material-specific restoration work such as metal, wood, ceramics, earthenware and stone artifacts by replacing synthetic resins currently being used for preservation treatment of cultural assets. Existing synthetic resins have the issue of cutting force resulting from high strength, deflection resulting from long hardening time, contaminating the surface of artifacts through staining on tools or gloves and need for re-treatment resulting from material discoloration. Accordingly, paste type restoration material most widely being used in the field of cultural assets preservation treatment was selected and examined the property to select it as an object of comparison. Based on such process, epoxy putty was developed according to the kind of agent, hardener and filler. For the purpose of solving the issues of existing material and allowing the epoxy putty developed to have similar property, property experiments were conducted by selecting agents and hardeners with different characteristics and conditions. The study findings showed that both kinds are paste type that improved work convenience and deflection issue as a result of their work time of within 5~10 minutes that are about 3~10 times shorter than that of existing material. In regards to wear rate for increasing cutting force, it improved by about 3 times, thereby allowing easy molding. For the purpose of improving the issue of surface contamination that occurs during work process, talc and micro-ballon were added as filler to reduce the issue of stickiness and staining on hand. Furthermore, a multi-purpose restoration material with low shrinkage, low discoloration and high cutting force was developed with excellent coloring, lightweight and cutting force features.

Study on the Property and Applicability of the Bisphenol-A Type Epoxy Putty According to the Mix of Filler (개발된 Bisphenol-A계 Epoxy Putty의 충전제 배합에 따른 물성 및 적용성에 관한 연구)

  • Wi, Koang-Chul;Oh, Seung-Jun
    • Journal of Conservation Science
    • /
    • v.32 no.4
    • /
    • pp.459-469
    • /
    • 2016
  • The goal of this study was to examine property changes induced by the choice of filler used with an epoxy resin that was developed in 2014 to restore cultural assets and consider the applicability of the resin as a restorative agent. The properties of putty mixed with 9 types of fillers and as-developed resins were compared with those of existing materials with regard to stability, superiority and applicability. The potential of the putty as an alternative material was also examined. The materials produced the best adhesiveness, color change and hardness results when mixed with lime. Micro balloon produced the best wear rates and hardening times, while diatomite produced the best tensile and compressive strengths. A plaster and white mineral pigment mixture produced the best specific gravity. Every material except for lime exhibited about 2.5-20 times higher wear rates than the existing material, which is thought to exhibit an excellent cutting force. The hardening time was enhanced by about 0.5-9 times to improve convenience. The stability of the relic was also ensured by improving hand staining without any shrinkage or deformation. The material exhibited about 0.5-27 times less yellowing. Thus, it is thought to be a material that can reduce property changes and reduce the degree of relic fatigue which occurs during reprocessing and sense of difference from relic.

A Study on the Ratio between Epoxy putty and Original Sculpey for the Ceramic Restoration -As Focus on the White Porcelain of the Joseon Dynasty Period- (도자기 복원을 위한 소성점토와 에폭시퍼티 혼합비 연구 - 조선백자를 중심으로 -)

  • Kim, Heejin;Koh, Minjeong;Lim, Sookyung;Lee, Taejin;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.14
    • /
    • pp.29-35
    • /
    • 2013
  • In cases, such as white porcelain with openwork lotus scroll design, where the ceramics has intricate form and decorations, we normally use casts to restore the work, in that current restoration materials have short molding time which causes difficulties in delicate work. However, since using a cast for restoration requires longer work-time and uses more materials, we decided to restore in direct. Since the molding time in the restoration material is closely related to the workability, restoration material which secures longer work hours is necessary when directly restoring a complex form of body. Therefore we experimented on the work-time, color variation and workability as time passes by making mixtures of Epoxy putty and Baked clay in different ratios. As a result of the experiment, the mixture ratio of OS8:RQ2 turned out to be the most effective ratio.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

Thickness Measurement of Adhesive Layer of Multilayer Using Power Cepstrum Technique (전력 켑스트럼 기법을 이용한 다층구조물 접착면의 두께측정)

  • Shin, Jin-Seob;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.26-30
    • /
    • 1997
  • In this paper, the thickness measurement method of adhesive layers of multilayers using power cepstrum signal processing technique has been proposed. The peak values for reflected signal from each layer have been separated by power cepstrum technique. Therefore, thickness of adhesive layers have been measured by the intervals of peak signal. In the experiment, the adhesive layers of 0.5mm-0.75mm thickness using epoxy(2-Ton and Plastic Steel Putty(A)) between the aluminum and the brass were formed. The adhesive layer thickness which is calculated with data of reflected signal by ultrasonic pulse-echo method was within error 1.34% of the measured values.

  • PDF

WETTABILITY OF POLYVINYLSILOXANE IMPRESSION MATERIALS AND IMPROVED STONE MATERIALS (부가중합 실리콘 인상재 및 모형재의 젖음성에 관한 비교 연구)

  • Cho, Lee-Ra;Chung, Kyung-Ho;Kim, Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.191-199
    • /
    • 2000
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined the impression quality in clinical condition and the wettability of impression and die material. Four commercially available addition silicone impression material (Express, Examix, Contrast, Perfect) and three die materials (Die-Keen, Vel-Mix, Fuji-Rock) were studied. A total of 50 putty/wash and heavy body/wash impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned epoxy resin casts from the impressions and clinically measured sulcus depths, The same impression materials were used to produce 3 groups of die stone casts form void entrapment die had been exposed to milk. Voids in the impression body and stone casts ere counted under a stereoscopic microscope. From the experiment, the following results were obtained : 1. Sulcus reproduction ability of additional silicone impression material were diminished in order of Express, Examix, Perfect, Contrast. The significant difference was found between Perfect and other material. Heavy body/wash combination was superior In putty/wash method n Perfect impression material. 2. In direct observation, Contrast showed least void in impression body but correlations ere not found between sulcus reproduction and void production. 3. In void entrapment laboratory test, wettability were diminished in order of Examix, Contrast, Express, Perfect. Clinical impression recording seems not to correlate with laboratory test. 4. The wettability of die material to impression material was not different in Express, Examix, Contrast. But, in Perfect, Die-Keen had superior wettability to others.

  • PDF