• 제목/요약/키워드: Equivalent System

검색결과 2,968건 처리시간 0.027초

전차선로 시스템의 5 도체 등가 축약 모델링 (A Reduced Equivalent 5 conductors Modeling of the Catenary System)

  • 이한민;오광해;이장무;창상훈;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권12호
    • /
    • pp.684-690
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model, then the line constants of this equivalent five-conductors model are calculated. This paper shows the reducing process about the real system of the field by using the proposed theory. Also the line constants of reduced system are provided in this paper.

거대 구조물의 국부진동계의 등가계 산출과 이를 이용한 최적구조변경법 (A Study on the estimation of an equivalent system of a local vibration system of a huge structure and the Optimum Structural Modification Method)

  • 박석주;황문주;오창근;김성우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 춘계학술발표회 논문집
    • /
    • pp.120-127
    • /
    • 1998
  • It is very difficult to execute the vibration analysis of a huge strucutre, which takes up much time and expense. In this paper we intend to make the equivalent system of a local vibration system of a huge structure with a view to improving the dynamic characteristics and reducing time and expense. First of all, upper deck structure model is maded. And we perform the vibration analysis by the Substructure Synthesis Method and execute the exciting test for the upper deck structure model, and observe the coincidences of two results to confirm the reliability of the analyzing tools used. To make the equivalent system, we give boundary condition to sub-structure that want to be modified and execute the Sensitivity Analysis Method and the Optimum Structural Modification Method. And we execute the structural modification of the equivalent system.. The following can be found from this study. 1. The analytical results are generally coincident with each other. 2. The equivalent system of the superstructure model can be easily obtained using the sensitivity analysis metho and the optimum structural modification method. 3. The structural modification using the equivalent system can be obtained good results above 90% of object value.

  • PDF

마찰감쇠기-가새 시스템의 확률분포 기반 등가선형화에 관한 실험적 연구 (Experimental Study on the Probability-based Equivalent Linearization of a Friction Damper-Brace System)

  • 강경수;박지훈
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.394-403
    • /
    • 2006
  • A new equivalent linearization technique is proposed for a friction damper-brace system (FDBS) idealized as a elastoplastic system. The equivalent linearization technique utilizes secant stiffness and dissipated energy defined by the probability distribution of the extremal displacement of the FDBS. In addition, a conversion scheme is proposed so that an equivalent linear system is designed first and converted to the FDBS. For comparative study, an existing model update technique based on system identification is modified in a form appropriate to update single element. For the purpose of verification, shaking table tests of a small scale three-story shear building model, in which a rotational FDBS is installed, are conducted and equivalent linear systems are obtained using the proposed technique and the model update technique. Complex eigenvalue analysis is conducted for those equivalent linear systems, and the natural frequencies and modal damping ratios are compared with those obtained from system identification. Additionally, RMS and peak responses obtained from time history analysis of the equivalent linear systems are compared with measured ones.

등가계를 적용한 열차의 동적거동에 관한 연구 (A Study on the Dynamics of Train Using Equivalent System)

  • 조동현;임진수
    • 소음진동
    • /
    • 제10권1호
    • /
    • pp.117-122
    • /
    • 2000
  • The dynamics of train has recently been analysed in many cases and very complex nonlinear creep theories have been developed by many engineers. But much calculation time is spent and latest complex creep theories cannot be adapted in train analysis. In this study efficient and fast train analysis method was suggested. Many of degree of freedom were reduced in multi-vehicle system using equivalent system and fast calculation time was achieved. And the accuracy of equivalent system method was proved by linear and nonlinear dynamic analysis.

  • PDF

등가계를 이용한 열차의 횡방향 거동 연구 (A Study on the Lateral Dynamics of a Train using Equivalent System)

  • 박동일;임진수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.345-352
    • /
    • 1998
  • The dynamic analysis of a train system has tended to analyze one vehicle or subsystem of that rather than to analyze entire vehicles. But, the speeding and lightening of a train requires more accurate analysis. Thus, the analysis of entire vehicles is required but it spends much time. Therefore, it is needed to find out the new analytic method which is more accurate and efficient. This paper suggests a new method for analyzing a multi-vehicle system more efficiently, using‘mechanical impedance’At first, get the impedance of vehicles which influence the dynamics of the object car, through analyzing the dynamics of a vehicle. ‘Equivalent system’, a simple mechanical system, of which the impedance is similar to that ,is proposed. Then, the equivalent system was applied to a vehicle and it showed that the equivalent system works like a real vehicle system. Finally, we tried non-linear analysis of a vehicle to which the equivalent system is applied.

  • PDF

전차선로 시스템의 등가 축약 모델 (A Reduced Equivalent model of the Catenary System)

  • 이한민;오광해;이장무;한문섭;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.415-420
    • /
    • 2003
  • This paper estimates line constants of equivalent five-conductors model by using the reduced equivalent method. Actually, the catenary system is considered by the equivalent five-conductors model in the electrical aspect. Therefore, we should compose the catenary system of the equivalent five-conductors model. And then we calculate line constants of this equivalent five-conductors model. This paper shows the reducing process about the real system of the field by using the proposed theory and also line constants of reduced system

  • PDF

전력계통 과도현상 해석을 위한 상영역에서의 등가축약 기법 (A Phase-Domain Equivalent Representation for Electromagnetic Transients Studies)

  • 정병태;김성희;허성일;안복신;홍준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.731-733
    • /
    • 1996
  • In this paper, a new time-domain reduction method for unbalanced 3 phase power systems will be represented. The impulse response of the system is used to identify a discrete-time equivalent filter model. The model is formulated directly in the phase domain. Each phase has a self-mode equivalent model and two mutual-mode equivalent models. The equivalent model is determined by the transfer function identification technique based on the Prony analysis. The model is implemented in EMTDC and tested with an unbalanced 3 phase network. The result of test showed that the equivalent model is accurate.

  • PDF

한전 실시간 시뮬레이터를 위한 등가계통 구성 연구 (Development of Equivalent Systems for the KEPCO Enhanced Power System Simulator)

  • 장길수;윤용범;김용학
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1434-1440
    • /
    • 1999
  • For the real-time power system analysis, there exists a limitation to the scale of the system to be simulated, hence it is necessary for the real-time simulation to develop reduced equivalent systems which preserve the desired property of the original system. In this paper, a procedure for developing an equivalent system whose scale is reduced within the hardware capacity of a real-time simulator is proposed. Also, the proposed procedure is applied to a KEPCO's system. The comparison between the original system and equivalent systems illustrates the capabilities of the proposed procedure.

  • PDF

등가 1 자유도계에 의한 철근콘크리트 건물의 비선형 동적해석의 검토 (Estimation of Nonlinear Response for Moment Resisting Reinforced Concrete Frames Using Equivalent SDOF System)

  • 전대한;노필성
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.205-212
    • /
    • 2003
  • To evaluate the seismic performance of multistory building structures use an equivalent SDOF model. This paper presents a method of converting a MDOF system into an equivalent SDOF model. The principal objective of this investigation is to evaluate appropriateness of converting method through perform nonlinear time history analysis of a multistory building structures and an equivalent SDOF model. The hysteresis rules to be used an equivalent SDOF model is obtained from the pushover analysis. The conclusion of this study is following; A method of converting a MDOF system into an equivalent SDOF model through the nonlinear time history response analysis is valid. The representative lateral displacement of a moment resisting reinforced concrete frames is close to the height of the first modal participation vector $_1$$\beta$$_1$u}=1. It can be found that the hysteresis rule of an equivalent SDOF model have influence on the time history response. Therefore, it is necessary for selecting hysteresis rules to consider hysteresis characteristics of a moment resisting reinforced concrete frames.

  • PDF

4포트 커넥터 시스템의 등가회로 변환에 관한 연구 (Equivalent Circuit Model for Four Port Connector System)

  • 심민규;김종민;나완수
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.