• 제목/요약/키워드: Even harmonic

검색결과 157건 처리시간 0.03초

GIC 적용 대역통과필터를 이용한 컴퓨터 부하의 직렬 아크고장 전류 우수고조파 분석 (Even Harmonic Analysis of Series Arc-fault Current Using BPF of GIC Application in Computer)

  • 고원식;문원식;방선배;김재철
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1554-1560
    • /
    • 2012
  • In this paper, the even harmonic current(2nd, 4th, 6th, 8th) of the arc fault current and normal current were measured in computer load and analyzed. The BPF with GIC was developed to detection of harmonic, the exact center frequency and a high degree of sharpness could be easily obtained. The total even harmonic distortion due to series arc fault in computer load was 31.2%, this value was increased 3.9 times better than the total even harmonic distortion of normal current. The results of analysis of arc fault current RMS variation rate and Peak variation rate per half-cycle, The RMS average variation rate are as follows ; the 2nd harmonic was 0.24, the 4th harmonic was 0.15, the 6th harmonic was 0.19, the 8th harmonic was 0.25, respectively. The Peak average variation rate are as follows ; the 2nd harmonic was 0.19, the 4th harmonic was 0.12, the 6th harmonic was 0.13, the 8th harmonic was 0.15, respectively. The results of this analysis utilize data to detect of series arc fault on wiring of computer load.

Harmonic Analysis of Reactor and Capacitor in Single-tuned Harmonic Filter Application

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.239-244
    • /
    • 2011
  • Industrial power distribution system includes many kinds of non-linear loads, which produce the harmonics during energy conversion transition. The single-tuned passive filter is widely used to absorb the harmonics and attenuate its undesirable effect in the distribution system. However, the passive filter might be severely stressed, and sometimes even damaged, due to the absorption of harmonics. There is voltage rise on the capacitor when the single-turned harmonic filter is applied. When the capacitor voltage rose above the allowable limit, the expected life of the capacitor will considerably deteriorate. On the other hand, the reactor can experience the spike voltage even if the voltage and current of the capacitor are within the allowable limit, and this accumulated voltage stress of the reactor causes its premature fault. In this paper, we analyzed and compared the harmonic voltage and current of the reactor and capacitor in a single-tuned harmonic filter through the EMTP software and verified them with the experimental results.

Even Harmonic Mixer를 이용한 2.4GHz ISM band용 Direct Conversion방식의 RF Module 설계 및 제작 (Design and Fabrication of Direct Conversion RF Module using Even Harmonic Mixer for 2-4GHz ISM band)

  • 이주갑;윤영섭;최현철
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.222-226
    • /
    • 2001
  • In this paper, 2.4GHz RF Module using Even Harmonic Mixer(EHM) was designed and fabricated for Direct conversion(DC) system. By minimizing performance degradation of DC system with DC offset and LO radiation, the capability of minimization and one chip solution in wireless system was proposed. The designed EHM using anti-parallel diode pair represented 9dB conversion loss and about -60dBm 2LO leakage radiation in RF port, and output reflection and reverse transmission characteristic of low noise amplifier was improved. So superior DC offset suppression characteristic is expected. RF Module which consists of EHM, LNA, RF amplifier, Frequency synthesizer and Duplexer was designed and fabricated.

  • PDF

배전계통의 고 임피던스 고장 검출 고조파 변수 성능 평가 (Performance Evaluation of the Harmonic Parameters for High Impedance Fault Detection in Distribution System)

  • 오용택;김창종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.883-885
    • /
    • 1997
  • High impedance fault(HIF) is random in its behavior even in a similar environment. The detection of Ire HIF has focused on the development of algorithms based on harmonic, parameters of the arc currents. However, a fact that proper selection of the harmonic parameters, rather than algorithm selection, is more important is shown in this paper by applying three different performance evaluation methods on two HIF detection algorithms using eight harmonic parameters.

  • PDF

밀리미터파 대역 제2고조파 출력 발진기의 주입동기 특성 (Injection Locked Synchronization Characteristics of a Millimeter Wave Second Harmonic Oscillator)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1700-1705
    • /
    • 2013
  • A second harmonic millimeter wave oscillator utilizing sub-harmonic injection-synchronization is presented. A 8.7GHz oscillator with MES-FET is designed, and is driven as a harmonic output oscillator at 17.4GHz by means of sub-harmonic injection-synchronization. The oscillator operates as a multiplier as well as a oscillator in this scheme. Adopting this method, a high sable, high frequency millimeter wave source is obtainable even though self-oscillating frequency of an oscillator is relatively low. The range of injection-synchronization is about 26MHz, and is proportional to the input sub-harmonic power. The spectrum analysis of the 2nd harmonic output frequency shows remarkably decreased the phase noise level.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Three Characteristic Beltrami System in Even Dimensions (I): p-Harmonic Equation

  • Gao, Hongya;Chu, Yuming;Sun, Lanxiang
    • Kyungpook Mathematical Journal
    • /
    • 제47권3호
    • /
    • pp.311-322
    • /
    • 2007
  • This paper deals with space Beltrami system with three characteristic matrices in even dimensions, which can be regarded as a generalization of space Beltrami system with one and two characteristic matrices. It is transformed into a nonhomogeneous $p$-harmonic equation $d^*A(x,df^I)=d^*B(x,Df)$ by using the technique of out differential forms and exterior algebra of matrices. In the process, we only use the uniformly elliptic condition with respect to the characteristic matrices. The Lipschitz type condition, the monotonicity condition and the homogeneous condition of the operator A and the controlled growth condition of the operator B are derived.

  • PDF