• Title/Summary/Keyword: Exit Light

Search Result 70, Processing Time 0.028 seconds

Analysis of Evacuation Route Selection Pattern of Occupant according to Installation Type of Exit Light and Opening/Closing Direction of Door (유도등 설치유형 및 피난구 출입문 개폐방향에 따른 재실자의 피난경로 선택패턴분석)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.28-34
    • /
    • 2019
  • The purpose of this study is to examine the influence of occupant's path selection on the shape of the pictogram and the opening/closing of the door. This study was carried out through a simulation experiment using computer virtual reality. Exit light pictogram for exit door and exit light pictogram for passage were arranged for each scenario in type T corridor and type + corridor. The computer graphic was used to carry out the simulation. In addition, we analyzed the response of human behavior according to the two directions (left and right) of exit light pictogram for exit door and the effect of opening direction of doorway. In addition, the change of decision-making according to the presence or absence of exit light pictogram for passage was confirmed. The results of the direction selection response were as follows. First, in the case of the T-shaped corridor, if the exit light was not installed on the door, it was influenced by the opening direction of the door. Second, when the exit light is attached to the door, the selectivity in the direction that matches the exit light pictogram direction is high. As a result, it was confirmed that the pictogram direction of the exit light influenced the evacuation route selection of the occupants.

A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance (휘도비 측정을 통한 유도등의 경년변화 연구)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.181-185
    • /
    • 2019
  • In this study, Exit light installed in offices, malls, hospitals, and factories were analyzed to analyze the luminance performance of CCFL and LED light sources. In addition, fire protection products with electrical characteristics such as Exit light may change their performance due to ambient temperature, humidity, and dust. So it was extracted by installation place and analyzed its characteristics. As a result of the experiment, Exit light for CCFL type showed the value of 'ratio of luminance 2' for large, medium and small. Considering that the reference value was 'lower than 9', the value was very good and it can be seen that there is almost no change in ratio of luminance due to aging. The Exit light for LED type showed a value of 'ratio of luminance 5', which means that the light on the display surface is not uniform. In addition, there was almost no change in ratio of luminance due to ageing, but the ratio of luminance was larger than Exit light for LED type. This is an unsatisfactory result from a visual point of view. To improve this, it is necessary to disperse the light of LED light source and strengthen the regulation on ratio of luminance.

A Study of Stability Analysis for Exit Light (유도등의 안정성 해석에 관한 연구)

  • Jung, Jong-Jin;SaKong, Seong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.81-85
    • /
    • 2008
  • In this study, Standards of Lighting Appliance and Standard of Model Approval and Inspection Technology for EXIT LIGHT are compared so as to analyze stability of a exit light which is fire product. Test items, which are not included in Standard of Model approval and Inspection Technology for EXIT LIGHT, are deduced from aforementioned comparison and analysis. Also the derived test items are experimented with a exit light. For a power factor correction, a power factor correction circuit is designed and power factor, crest factor, asymmetry ratio, luminance variation are analyzed. In order to show the validity of designed circuit, current waveform and voltage waveform are measured.

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

The Study on the exit taxiway of an airpark used in LSA (경량항공기 이착륙장의 탈출유도로에 대한 연구)

  • Shin, Dai-Won;Shin, Hong-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.3
    • /
    • pp.70-76
    • /
    • 2010
  • In this study, we surveyed the operating status of the Light Sport Aircraft(LSA) in Korea, and reviewed the minimum requirements of the airpark for LSA. We are discuss about increased aerodrome traffic density and safety improvement, through the installation of the exit taxiway. The shape of the exit taxiway of an airpark used in LSA is a rectangle for usable two way direction of runway. The array types of exit taxiway influence paved and unpaved runway occupancy time of LSA.

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

CORE DESIGN CONCEPTS FOR HIGH PERFORMANCE LIGHT WATER REACTORS

  • Schulenberg, T.;Starflinger, J.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.249-256
    • /
    • 2007
  • Light water reactors operated under supercritical pressure conditions have been selected as one of the promising future reactor concepts to be studied by the Generation IV International Forum. Whereas the steam cycle of such reactors can be derived from modem fossil fired power plants, the reactor itself, and in particular the reactor core, still need to be developed. Different core design concepts shall be described here to outline the strategy. A first option for near future applications is a pressurized water reactor with $380^{\circ}C$ core exit temperature, having a closed primary loop and achieving 2% pts. higher net efficiency and 24% higher specific turbine power than latest pressurized water reactors. More efficiency and turbine power can be gained from core exit temperatures around $500^{\circ}C$, which require a multi step heat up process in the core with intermediate coolant mixing, achieving up to 44% net efficiency. The paper summarizes different core and assembly design approaches which have been studied recently for such High Performance Light Water Reactors.

A study on the Exit Areas in Vertical Type of Multiplex Cinema (수직형 복합상영관의 퇴장공간에 관한 연구)

  • Lee, Mi-Suk;Kwak, Jae-Hoon;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2004.05a
    • /
    • pp.60-65
    • /
    • 2004
  • This dissertation is focalized on examining research on the actual condition and problem in the exit-space-form of Multiplex Cinema and mutual relation of user and finding more efficient and reasonable project method through valuation of design elements which the user can feel. In result, 4 place which is newly opened after 1990's is analyzed in Seoul. It is researched that Many user feel inconvenience and discomfort when they recognize exit-space. In order to improve itthey want to feel at ease naturally with light-embeded sign and landscape space. The exit-space should be recognized that it is a part of cinema which have to be developed and planed for the inner part of cinema and security of user. Not death-space.

  • PDF

Design of Projection Optical System for Target Imaging Simulator with Long Exit Pupil Distance

  • Xueyuan Cao;Lingyun Wang;Guangxi Li;Ru Zheng
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.745-754
    • /
    • 2023
  • In order to test the recognition ability and accuracy of a target imaging simulator under the irradiation of solar stray light in a laboratory environment, it needs to be fixed on a five-axis turntable during a hardware-in-the-loop simulation test, so the optical system of the simulator should have a long exit pupil distance. This article adopts a secondary imaging method to design a projection optical system suitable for thin-film-transistor liquid crystal displays. The exit pupil distance of the entire optical system is 1,000 mm, and the final optimization results in the 400 nm-850 nm band show that the modulation transfer function (MTF) of the optical system is greater than 0.8 at the cutoff frequency of 72 lp/mm, and the distortion of each field of view of the system is less than 0.04%. Combined with the design results of the optical system, TracePro software was used to model the optical system, and the simulation of the target imaging simulator at the magnitude of -1 to +6 Mv was analyzed and verified. The magnitude error is less than 0.2 Mv, and the irradiance uniformity of the exit pupil surface is greater than 90%, which meets the requirements of the target imaging simulator.

LED Light Coupler Design for a Ultra Thin Light Guide

  • Lee, J.H.;Chang, W.;Choi, D.
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.3
    • /
    • pp.113-117
    • /
    • 2007
  • A LED light coupler is proposed for coupling light from a mini side LED of 0.4 mm height to a very thin (${\sim}0.3 mm$) light guide. Due to the ultra thinness of the light guide, conventional light couplings between LEDs and light guides do not provide adequate coupling efficiency. The designed LED coupler is a compound lens of 3.5 mm length, 1.2 mm height, and 3.3 mm width. The courier first collimates the light from the LED and then concentrates the light in a manner similar to a compound parabolic concentrate, (CPC) into the light guide. The exit surface of the coupler is additionally textured to have micro patterns in order to control the radiance profile.