• Title/Summary/Keyword: Exposure direction

Search Result 271, Processing Time 0.023 seconds

An Analysis of Sunshine According to the Blocks Direction by Location Type in Apartment Complex (아파트단지의 입지유형별 주동향에 따른 일조분석)

  • 장승재;박민용
    • Journal of the Korean housing association
    • /
    • v.14 no.5
    • /
    • pp.11-17
    • /
    • 2003
  • This study is aimed at analyzing on the sunshine according to the blocks direction by location type of apartment complex in Busan, to propose a planning on the decision of blocks direction and the improvement of architectural law in sunshine environment. The results of this study were as follows; On the basis of winter solstice in "□ block type", the average of ratio of shadow area in flat site is 51 % in apartment with a southern exposure, 39% in apartment with a south-eastern exposure. The average of ratio of shadow area in the descended site toward the north is 49% in apartment with a southern exposure, 34% in apartment with a south-eastern exposure. The average of ratio of shadow area in the descended site toward the south is 66% in apartment with a southern exposure, 53% in apartment with a south-eastern exposure.

A study on the Site Planning of the Dwellings in Hahoe Village (하회마을의 주택 배치에 관한 조사 연구)

  • 정명섭;혼마히로부미;호야노아키라;황정하;도근영;스가와라마사노리
    • Journal of the Korean housing association
    • /
    • v.11 no.3
    • /
    • pp.19-27
    • /
    • 2000
  • The purpose of this study is to examine exposure and direction in slope as well as entrance of site in order to research the site planning of the dwellings in Hahoe Village. In this study, the survey data during seventeen month from April 1998 to August 1999 was measured and analyzed. The result of this study were as follows ; 1) The rate of exposure and direction in slope as well as entrance of site was find out in order of the south(30~38%).east(22~28%).north(21~24%).west(14~22%) aspect. Among others, exposure was most due south.southeast.southwest aspect. 2) The interrelation of exposure and direction in slope as well as entrance of site was find out high within the limits of general visible.

  • PDF

A Study on the Vibration Characteristics by the Change of Impact Load Direction in the Collecting Plates of Electrostatic Precipitator (충결하중의 방향에 따른 정전집진기 집진판의 진동 특성 연구)

  • 나종문;이기백;양장식
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.247-256
    • /
    • 1995
  • In this paper, double exposure holographic interferometry using ruby pulse laser is formed in order to investigate the propagation of transient waves. The vibration characteristics according to the change of impact load direction, i.e., impacted in the shear direction and in the normal direction are analyzed. It was observed that the macroscopic trends of transient wave generation and propagation in the assembly of precipitator plates were almost similar regardless of the change of impact load direction. But the propagation and mixing of transient wave was advanced relatively slowly when impacted in the normal direction.

  • PDF

Effects of light direction and exposure times of plasma arc light on shear bond strength of metal brackets (Plasma arc light를 이용한 금속 브라켓의 부착시 광조사 방향과 중합시간이 전단결합강도에 미치는 영향)

  • Roh, Sang-Jeong;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.429-438
    • /
    • 2004
  • The purpose of this study was to compare the effects of different light direction exposure times and setting times when using plasma arc light on shear bond strength of metal brackets. 240 extracted human premolars were randomly assigned to one of 16 groups Standardized brackets were bonded to enamel using different light curing units (Plasma arc light and Halogen light), exposure times (Plasma arc light 2. 4, 6 seconds and Halogen light 20 seconds). and light directions [Vertical direction [V] and Oblique direction [O]). 8 groups were tested after 5 minutes and the remaining 8 groups after 24 hours. The metal brackets were bonded with Transbond XT. Shear bond strength was measured by a universal testing machine. The results were as fellows: There were as differences between the shear bond strengths of the Vertical groups (V) and Oblique groups (O). regardless of exposure times and types of light curing units (p>0.05). The shear bond strength of the group with 2 seconds of plasma light were significantly lower than other exposure time groups (P<0.05). The shear bond strength tested after 5 minutes was lower than after 24 hours (p<0.05) The Adhesive Remment Index (ARI) score showed no statistically significant difference among the different groups. The results of this study suggested that the light direction of plasma arc light had no influence on the shear bond strength of metal brackets to enamel. and exposure times more than 4 seconds produced shear bond strengths similar to those Produced with a conventional halogen curing light.

Individual Exposure Characteristics to Humidifier Disinfectant according to Exposure Classification Groups - Focusing on 4-1 and 4-2 Applicants - (가습기살균제 환경노출 판정등급에 따른 개인 노출 특성 분포 - 4-1차와 4-2차 신청자를 중심으로 -)

  • Lee, Seula;Yoon, Jeonggyo;Ock, Jeongwon;Jo, Eun-Kyung;Ryu, Hyeonsu;Yang, Wonho;Choi, Yoon-Hyeong
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.4
    • /
    • pp.370-380
    • /
    • 2019
  • Objective: This study was performed to investigate the distribution of individual exposure characteristics according to an exposure assessment classification for humidifier disinfectant and to identify the factors that influence assessment classification. Methods: We examined the exposure characteristics of 4,482 subjects who applied for the 4-1 and 4-2 assessments of environmental exposure to humidifier disinfectant conducted by the Korea Environmental Industry & Technology Institute (KEITI). Environmental exposure assessment classification was assessed using the following seven criteria: 1) Distance from humidifier to face; 2) Spray direction; 3) Time used, daytime 4) Time used, during sleep; 5) Time used, cumulative; 6) Exposure intensity; and 7) Cumulative exposure level. Each criteria was then classified as 'high' or low'. When participants answered for more than four criteria, exposure assessment was determined as 'definite,' 'probable,' or 'possible' depending on the ratio of 'high' responses. If participants' responses were inconsistent, exposure assessment was listed as 'unlikely.' If participants answered for less than four criteria, exposure assessment was considered 'indeterminate.' Results: For the exposure assessment classes, definite was assigned to 38.5% (1,725 subjects), probable assigned to 32.9% (1,474 subjects), 25.0% (1,122 subjects) were assigned to as possible, unlikely assigned to 0.1% (3 subjects), and indeterminate assigned to 3.5% (158 subjects). Overall, participants who used 'Oxy Ssakssak New Gaseupgi Dangbun,' 'Aekyung Gaseupgi Mate,' 'Homeplus Gaseupgi Chungjungje,' and 'E-Mart Gaseupgi Salgyunje' totaled 2,996, 557, 176, and 162 subjects, respectively. There was a statistical difference in the type of humidifier disinfectant products between high-exposed and low-exposed participants. Based on the assessment criteria of humidifier disinfectant exposure, subjects were likely to be in the highly exposed classes (definite and probable) when the subjects were exposed 1) for more than ten hours per day and 2) for more than four hours at night 3) when the total cumulative exposure time was higher than the average, 4) when the direction of humidifier spray was toward the face, 5) when the respiratory position was less than 1 meter of distance from the humidifier, 6) when the concentration of indoor contaminants (ug/m3) was higher than the average exposure intensity, and 7) when overall exposure level ($ug/m3^*hr$) was higher than the average exposure level. Conclusion: This study suggests that each exposure assessment criteria was able to appropriately estimate cumulative exposure levels.

A Study on the Usefulness of Breast Shielding Apron for Reducing Exposure Dose in Mammography (유방X선촬영 시 피폭선량 감소를 위한 유방촬영용 차폐복의 유용성에 관한 연구)

  • Koo, Bon-Yeoul;Kim, Ji-Won
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.99-104
    • /
    • 2019
  • Mammography, conducted every two years, causes cancer due to regular exposure to radiation while reducing rate of death caused by breast cancer. The study evaluates the effect of breast shielding apron made to shield off scattered radiation that occurs to the breast when the opposite side breast is mammogramed. AGD was measured using ACR phantom, composed of 50% mammary glands and 50% fat, and radiation was measured before and after wearing the apron on the breast when the opposite side of the breast is mammogramed. When CC direction mammography was conducted to a breast, the AGD was 1.84 mGy. When CC direction and MLO direction mammography were done to a breast, the average dose detected from the opposite side breast from four directions(top to bottom and medial to lateral) was $140{\mu}Gy$ with maximum dose of $256{\mu}Gy$ at medial side. After putting on the apron, the dose, caused by scattered radiation, was not detected from any of the four directions. Using of breast shielding apron is expected to minimize the radiation exposure by blocking scattered radiation to the breast shielded, when mammography is done to the opposite side breast.

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

Application of Biomarkers for the Assessment of Carcinogen Exposure and Cancer Risk (발암물질 노출량 산출 및 암 위해성 평가에 있어서 Biomcrker의 활용)

  • 이병무
    • Environmental Mutagens and Carcinogens
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • Risk Assessment is an important area in toxicology and the methodology for risk assessment has been developed. Mathematical models used for risk assessment include one-hit multi-hit, two-stage, probit logistic, multistage, and linearized multistage models. For the assessment of exposure dose, environmental monitoring has been applied, but it has limitation to accurately assess exposure level because the levels in the air, water, foods, and soil may vary depending on time of sampling. In addition, humans can be exposed to various sources of exposure and thus it will be impossible to estimate the total level of exposure in humans by environmental monitoring. To eliminate the limitation of environmental monitoring, a direct measurement of toxic materials or modified biomolecules (called biomarkers) associated with the exposure of toxic materials is needed. Here, scientific basis of biomarkers and future direction have been considered for the assessment of carcinogen exposure and cancer risk in humans.

  • PDF

Shielding Effect according to the Direction of Control Room Door Opening during Radiography (방사선촬영 중 제어실 문의 열린 방향에 따른 차폐효과)

  • Choi, Weon-Keun;Kim, Jung-Hoon;Kang, Bo-Sun;Bae, Seok-Hwan;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3347-3352
    • /
    • 2010
  • It is recommended that the door of control room is closed during radiography to protect a radiologic technologist. However, for those patients such as of emergency or pediatrics, the door must be kept open unavoidably to apply immediate medical administration and treatment on the potential case of emergency which could be happened through the course of radiography. In addition, it could be efficient by reducing patients waiting time when the door is open for a general case. This study was conducted to evaluate practical exposure rate to a radiologic technologist when the door is open during the radiography, and to find out the ways to minimize radiation exposure and to increase the efficiency simultaneously. Measuring practical exposure rate was fulfilled with glass dosimeter, and it was 2.02 mGy/week at the location of radiologic technologist under the condition that the door is open during the radiography, which was about 2.3 times higher than the 100 mR/week. It means that the considerable amount of scattered rays through the door opening, and increase exposure rate at the radiologic technologist. Hence we confirmed that a radiologic technologist probably overexposed if the door is open during the radiography. It was also confirmed by the Monte Carlo simulation that the exposure rate could be reduced up to approximately 1/100 by change only the door opening direction. In conclusion, since the proper door opening direction provides same shielding effect whether it is open or close, the door opening direction need to be considered when it is installed at radiography facilities.

Evaluation of Self-cleaning Property by Measuring Brightness of Tio2 Coating Ceramic Tile under Outdoor Exposure Test (옥외폭로시험 Tio2 코팅 세라믹 타일의 명도측정에 의한 방오특성 평가)

  • Shin, Dae-Yong;Kim, Kyung-Nam
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.6
    • /
    • pp.345-349
    • /
    • 2008
  • $TiO_2$ coating ceramic tile for self-cleaning purpose was prepared by the precipitant dropping method using $TiCl_4$ as a precursor. $TiO_2$ film was formed on the ceramic tile by spray-coating technique and heat-treated at $500^{\circ}C$ for 1 h. The size and crystalline structure of $TiO_2$ particles were 15.3 nm and anatase phase. The outdoor exposure tests were conducted and the effects of outdoor exposure test conditions, such as exhaust concentration of contamination materials (test places), the UV light intensity (irradiation direction) and coating amounts of $TiO_2$ on the self-cleaning properties were investigated by the brightness measurements. As a results, self-cleaning property of $TiO_2$ coating tile was affected by the coating amount of $TiO_2$ however, not affected by the UV light intensity included in sun's ray (irradiation direction). $TiO_2$ coating ceramic tile can be utilized for exterior finishing materials because of self-cleaning property of $TiO_2$ coating tile.