• Title/Summary/Keyword: FEAS

Search Result 57, Processing Time 0.034 seconds

Field emission properties of the silicon field emission arrays coated with diamond-like carbon film prepared by filtered cathodic vacuum arc technique (진공아크방전으로 제작된 다이아몬드상 탄소 박막이 코팅된 실리콘 전계 방출 소자의 전계 방출 특성)

  • 황한욱;김용상
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.4
    • /
    • pp.326-331
    • /
    • 2000
  • We have fabricated the field emitter arrays coated with diamond-like carbon (DLC) films that improved the field emission characteristics. The nitrogen doped DLC films are prepared by the filtered cathodic vacuum are (FCVA) tehnique. The activation energy of the nitrogen doped DLC films are derived from electrical conductivity measurements. The silicon field emission arrays (FEAs) were prepared by the VLSI technique. The turn-on field was rapidly decreasing and the emission current was remarkably increasing the DLC-coated FEAs than the non-coated silicon FEAs. In the nitrogen doped FEAs, the turn-on field decreased and the emission current increased with increasing the nitrogen found out the field emission current and the work function of the DLC-coated FEAs was remarkably decreased than that of the non-coated silicon FEAs. As nitrogen doping concentrations are increased the work function of FEAs is decreased and the field emission properties are improved in nitrogen doped DLC-coated FEAs. This phenomenon in due the fact that the Fermi energy level moves to the conduction band by increasing nitrogen doping concentration.

  • PDF

Low Work Function and Sharp Field Emitter Arrays by Transfer Mold Fabrication Method

  • Nakamoto, Masayuki;Sato, Genta;Shiratori, Kohji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.1049-1052
    • /
    • 2007
  • Extremely sharp and uniform Transfer Mold FEAs with thin film low work function TiN emitter material have been fabricated by controlling the thickness of the coated emitter materials to realize high efficient, high reliable and low-cost vacuum nanoelectronic devices..Their tip radii are 8.3-13.8 nm. Turn-on electric fields of the Ni FEAs and TiN-FEAs resulted in the low electric field values of $31.6\;V/{\mu}m$ and $44.2V/{\mu}m$,respectively, at the short emitter/anode distance: less than $30\;{\mu}m$, which are lower than those of conventional FE As such as Spindt type FEAs and carbon nan otube FEAs The Transfer Metal Mold fabrication method is one of the best methods of changing emit ter materials with sharp and uniform emit ter shapes.

  • PDF

A new procedure for load-shortening and -elongation data for progressive collapse method

  • Downes, Jonathan;Tayyar, Gokhan Tansel;Kvan, Illia;Choung, Joonmo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.6
    • /
    • pp.705-719
    • /
    • 2017
  • Progressive Collapse Method (PCM) has been broadly applied to predict moment-carrying capacity of a hull girder, however accuracy of PCM has not been much studied. Accuracy of PCM is known to be dependent on how Load-Shortening and -Elongation (LSE) curve of a structural units are well predicted. This paper presents a new procedure to determine LSE datum based on box girder Finite Element Analyses (FEAs) instead of using finite element model of stiffened panels. To verify reliability of FEA results, the simple box girder collapse test results are compared with FEA results of same box girders. It reveals one frame-based box girder model is sufficiently accurate in terms of ultimate strengths of the box girders. After extracting LSE data from the box girders, PCM-based moment-carrying capacities are compared with those from FEAs of the box girders. PCM results are found to be equivalent to FEAs in terms of moment-carrying capacity if accurate LSE data are secured. The new procedure is applied to well-known 1/3 scaled frigate full section. Very excellent moment-carrying capacity of frigate hull section is obtained from PCM with LSE data from box girder FEAs.

The Assessment of Appropriateness of Acupuncture Methodology Based on STRICTA Recommendations;The Discussion of 5 Systematic Reviews and Their Objects 58 Randomized Controlled Trials Using the New Tool (STRICTA 권장안에 기초한 침 연구방법론의 적절성 평가;새로운 평가지수를 이용한 5편 Systematic Review와 그 대상인 58편 무작위대조시험의 고찰)

  • Kim, Woo-Young;Lee, Seung-Deok;Lim, Byung-Mook;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.24 no.5
    • /
    • pp.151-170
    • /
    • 2007
  • Backgraounds : Recent studies provide the evidences that the efficacy of acupuncture may be no better than placebo or inconclusive. These results are very different from those of the actual clinical situations in many acupuncture medical institutions. Objectives : The present study was designed to evaluate the influencing factors which affect the efficacy of acupuncture scale(FEAS) as the methodological assessment tool of acupuncture for examining acupuncture interventions and to demonstrate the importance of it in randomized controlled trials of acupuncture. Data sources : Electronic data were retrieved from NDSL, Pubmed, sciencedirect, LWW, OVID, Black-Well Synergy, Wiley Interscience, EBSCO HOST, springer, PML, and Kluwer. No electronic data were collected from MEDLIS and MEDLAS. Study selection : The inclusion criteria were five systematic reviews included in Alberta study and all randomized controlled trials obtained from their references. Study analysis : The acupuncture rationale, methods of stimulation, treatment regimen, and the practitioner's background were rated by FEAS, and the scores were compared with those by other methodological assessment tools. Results : The number of positive conclusions of high-rank RCTs by FEAS was the same as or higher than that of high-rank RCTs by other methodological assessment tools. Conclusions : We have analysed 5 systematic reviews and their objectives 58 RCTs using FEAS. Practitioner's background has been described slightly in some reviews and studies. It may directly influence the effectiveness of acupuncture negatively in the systematic reviews.

  • PDF

A New Structure of Triode-type CNT-FEAs for Enhanced Electron Emission and Beam Focusing

  • Jun, Pil-Goo;Kwak, Byung-Hwak;Noh, Hyung-Wook;Lee, Soo-Myun;Uh, Hyung-Soo;Park, Sang-Sik;Ko, Sung-Woo;Cho, Euo-Sik;Lee, Jong-Duk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.456-458
    • /
    • 2004
  • We proposed a novel triode-type carbon nanotube field emitter arrays in which extracted gate is surrounded by CNT emitters. We carried out 3-dimensional numerical calculations of electrostatic potential for the proposed CNT-FEAs using the finite element method and compared the results with those obtained from the structure of conventional CNT-FEAs. It was found that the proposed structure could reduce the turn-on voltage for electron emission and improve beam focusing.

  • PDF

Vacuum Dependency of Si, Co Slicide and Mo Silicide FEAs

  • Lee, Jong-Duk;Shim, Byung-Chang;Park, Byung-Gook;Uh, Hyung-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.685-688
    • /
    • 2002
  • In this paper, it is reported that the anode current changes at the constantly applied gate voltages and the current-voltage (I-V) characteristics of Si, Co silicide and Mo silicide field emitter arrays (FEAs) depending on vacuum level from a $10^{-9}$ torr to a $10^{-6}$ torr. The mechanism of the robustness of anode current degradation of Mo silicide FEAs under poor vacuum conditions can be explained by the model of tolerance for the oxygen adsorption and oxidation at the silicide surface. Also, we present the changes of emitting area and work function of the emitters according to vacuum level.

  • PDF

Building Transparency on the Total System Performance Assessment of Radioactive Repository through the Development of the FEAS Program (FEAS 프로그램 개발을 통한 방사성폐기물 처분장 종합 성능 평가(TSPA) 투명성 증진에 관한 연구)

  • 서은진;황용수;강철형
    • Tunnel and Underground Space
    • /
    • v.13 no.4
    • /
    • pp.270-278
    • /
    • 2003
  • Transparency on the Total System Performance Assessment (TSPA) is the key issue to enhance the public acceptance for a permanent high level radioactive repository. Traditionally, the study on features, events and processes (FEPs) and associated scenarios has been regarded as the starting point to open the communicative discussion on TSPA such as what to evaluate, how to evaluate and how to translate outcomes into more friendly language that many stakeholders can easily understand and react with. However, in most cases, it has been limited to one way communication, because it is difficult for stakeholders outside the performance assessment field to assess the details on the story of the safety assessment, scenario and technical background of it. Fortunately, the advent of the internet era opens up the possibility of two way communication from the beginning of the performance assessment so that every stakeholder can exchange their keen opinions on the safety issues. To achieve it, KAERI develops the systematic approach from the FEPs to Assessment methods flow chart. All information is integrated into the web based program named FEAS (FEp to Assessment through Scenario development) under development in KAERI. In parallel, two independent systems are also under development the web based QA(Quality Assurance) system and the PA(Performance Assessment) input database. It is ideal to integrate the input data base with the QA system so that every data in the system can checked whenever necessary. Throughout the next phase R&D starting from the year 2003, these three systems will be consolidated into one unified system.

Emission Characteristics of 0.7' Monochrome MOSFET-Controlled Field Emission Display in a High Vacuum Chamber

  • Lee, Jong-Duk;Oh, Chang-Woo;Kim, Il-Hwan;Park, Jae-Woo;Park, Byung-Gook
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.66-71
    • /
    • 2001
  • MCFEDs (MOSFET-Contoolled Field Emission Displays) were fabricated to evaluate the validity of MCFEA for display application. The electrical properties of FEAs (Field Emitter Arrays), HVMOSFETs (High-Voltage MOSFETs), and MCFEAs (MOSFET-Controlled Field Emitter Arrays) were measured. The extraction gate voltage of the FEAs to obtain the anode current of 10 nA/tip was around 71 V. The breakdown voltages of the HVMOSFETs were above 81 V for all the samples. The I-V characteristics of the MCFEAs showed that the emission currents of the FEAs were well controlled depending on the control gate voltages of the HVMOSFETs. To avoid the harmful effects during the packaging process, the performance of the MCFEDs was evaluated in a high vacuum chamber. The emission images of the MCFEDs were controlled through very-through operation. From the comparison with a conventional FED, it was proven that the poor uniformity of FED could be improved through the integration with HVMOSFET.

  • PDF

Molybdenum and Cobalt Silicide Field Emitter Arrays

  • Lee, Jong-Duk;Shim, Byung-Chang;Park, Byung-Gook;Kwon, Sang-Jik
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2000
  • In order to improve both the level and the stability of electron emission, Mo and Co silicides were formed from Mo mono-layer and Ti/Co bi-layers on single crystal silicon field emitter arrays (FEAs), respectively. Using the slope of Fowler-Nordheim curve and tip radius measured from scanning electron microscopy (SEM), the effective work function of Mo and Co silicide FEAs were calculated to be 3.13 eV and 2.56 eV, respectively. Compared with silicon field emitters, Mo and Co silicide exhibited 10 and 34 times higher maximum emission current, 10 V and 46 V higher device failure voltage, and 6.1 and 4.8 times lower current fluctuation, respectively. Moreover, the emission currents of the silicide FEAs depending on vacuum level were almost the same in the range of $10^{-9}{\sim}10^{-6}$ torr. This result shows that silicide is robust in terms of anode current degradation due to the absorption of air molecules.

  • PDF