• Title/Summary/Keyword: FR 490

Search Result 9, Processing Time 0.021 seconds

Study of Structural Stability for H-section Beams Made of Fire Resistant Steels (FR 490) at High Temperatures by Analytical Method (건축용 내화강재(FR 490) 적용 H형강 보부재의 고온내력 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.52-57
    • /
    • 2014
  • When structural elements of steel framed structures are exposed to fire situations, the structural stability begins to decrease due to dislocation of substantial. The increase of the beam length causes an additional stress and deflection. These can be serious factors to cause a severe failure of structures. To improve the fire resistance of beams, prevention of the heat from a fire by coating with fire protection material is essential for beams. The FR 490 was developed to enhance fire resistance compared with SM 490 steel. However, the fire resistance of FR 490 H-beams has not been evaluated by analysis method since it was developed. In this paper, materials properties in high temperature and a heat transfer and thermal stress theory were used in the evaluation of the fire resistance of FR490 H-beams. The fire resistance of FR490 steel beams was compared with that of SM490 beams. The comparison verified that the structural stability of FR490 beams at high temperature was superior to that of SM490 beams.

Evaluation of Structural Stability of Fire Resistant Steel Produced by Thermo-Mechanical Control Process at High Temperature (TMCP 내화강재의 고온 내력 평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.21-25
    • /
    • 2013
  • Fire resistance steel, grading 490 MPa, had developed by using Thermo-mechanical control process (TMCP) and it has better performance at welding, seismic resistance than those of the ordinary structural steel, But the fire resistance performance is required to verify against the ordinary fire resistance, FR 490. Therefore this study was done to make database of mechanical properties at high temperature and to evaluate the structural stability at high temperature in terms of materials and structural member such as H-section from that of FR 490. The result of this study was that the structural stability of TMCP was lower than that of ordinary FR 490 at the range up about $700^{\circ}C$.

Experimental Study on Making Databases for Fire Resistant Steel at High Temperature (내화강재의 고온특성 데이터베이스 구축 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.1-7
    • /
    • 2013
  • Fire at building can occur enormous damages to life, properties, and environment and the risk of fire breakout is going up higher because of application of combustible materials than before. Therefore, the steel industries are trying to develop fire resistant steel in order to sustain the load bearing capacity of steel structures during fire situation. In this paper, to give the basis data-bases for evaluation of structural stability of steel structures applied fire resistant steel, FR 490, the tests of mechanical and thermal properties at high temperature were conducted and the comparisons are done with the SM 490 that has the same mechanical one.

Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • v.17 no.1
    • /
    • pp.105-121
    • /
    • 2014
  • A fundamental limitation of steel structures is the decrease in their load-bearing capacity at high temperatures in fire situations such that structural members may require some additional treatment for fire resistance. In this regard, this paper evaluates the structural stability of fire-resistant steel, introduced in the late 1999s, through tensile coupon tests and proposes some experimental equations for the yield stress, the elastic modulus, and specific heat. The surface temperature, deflection, and maximum stress of fire-resistant steel H-section columns were calculated using their own mechanical and thermal properties. According to a comparison of mechanical properties between fire-resistant steel and Eurocode 3, the former outperformed the latter, and based on a comparison of structural performance between fire-resistant steel and ordinary structural steel of equivalent mechanical properties at room temperature, the former had greater structural stability than the latter through $900^{\circ}C$.

Analytical Study of the Fire Resistance for Beams Consisting of Fire Resistant Steels with a Both Fixed Boundary Conditions (양단 고정단인 건축용 내화강재 적용 보부재의 해석적 내화성능 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.82-86
    • /
    • 2016
  • The fire resistance of a statistically indeterminate beam made of fire resistant steel was analyzed using the mechanical and thermal databases and compared with that of an indeterminate beam constructed of ordinary structural steel to not only determine the fire resistance performance of a statistically indeterminate beam itself, but also to determine if it is stable to test the fire resistance performance with a determinate beam built with ordinary structural steel instead of an indeterminate beam made from fire resistant steels. The results showed that the fire resistance of an indeterminate beam consisting of fire resistant steels is better than that of a determinate beam made of SS 400 and if the length of the beam built with FR 490 is longer, the displacement of the beam is higher. In addition, the fire test with a determinate beam made of SS 400 is was more conservative than that of an indeterminate beam made of FR 490 in the range of the same length. Therefore, another measure should be considered if beams built with FR 490 are longer than thos of SS 400.

Mitochondrial Distribution and Methionine Uptake in Fragmented and Non-fragmented Embryos Derived from Multi-pronuclei Zygotes in Human In Vitro Fertilization (IVF) Program (사람 다수정난자의 체외배양시 Fragmented Embryo와 Non-fragmented Embryo에서의 Methionine 유입량 및 미토콘드리아 분포양상의 비교)

  • Do, B.R.;Chung, M.K.;Chang, M.K.;Lee, K.A.;Ko, J.J.;Yoon, T.K.;Cha, K.Y.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.22 no.3
    • /
    • pp.279-285
    • /
    • 1995
  • Despite the frequent incidence of embryo fragmentation in early human embryos, the reason of the embryo fragmentation has not been known yet. This study was conducted to investigate the histological difference(s) between fragmented (FR) and non-fragmented (NFR) human embryos focusing on comparison of mitochondrial distribution and protein synthesis. Multi-pronuclei zygotes (MPZ) such as three or more pronuclei containing in human in vitro fertilization and embryo transfer (IVF-ET) program were used for this study. MPZ were cultured in TCM-199 supplemented with 10% of human fetal cord serum (hFCS) in 5% $CO_2$ incubator at $37^{\circ}C$ for 24 hours. The cleaved embryos to 2-4 cells after 24 hours were grouped by their grade of fragmentation. Embryos were stained with Rhodamine123 (Rh123) and fluorescence was evaluated under the fluorescence microscope through PB 450-490 filter (Leitz). Regarding to protein synthesis during early human embryogenesis, there is no significant difference in the amount of synthetic proteins between FR and NFR embryos. Distribution of cytoplasmic organelles in embryos was evaluated by transmission electron microscope (TEM). The cytoplasmic distribution of mitochondria was different between FR and NFR embryos. The mitochondrial distribution was even in NFR, whereas severely aggregated in FR. It is not able to clarify in the present study whether this uneven mitochondrial distribution in FR embryo is the reason for embryo fragmentation or is the result from fragmentation. Physiological disparity related to the mitochondrial distribution may be one of the reasons for embryo fragmentation. Further studies should be addressed to investigate the physiological differences between FR and NFR embryos.

  • PDF

Design of Microstrip-fed Dual Band Monopole Antenna for WLAN (마이크로스트립 급전 무선랜용 이중대역 모노폴 안테나 설계)

  • Nam, Ju-Yeol;Lee, Young-Soon
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.5
    • /
    • pp.490-495
    • /
    • 2016
  • In the present study, a microstrip-fed monopole antenna is proposed for wireless local area network (WLAN) operations which cover dual band of 2.4 GHz (2.4 ~ 2.484 GHz) and 5 GHz (5.15 ~ 5.825 GHz). In order to obtain its compact structure and good omnidirectional radiation patterns, a modified inverted L-shaped slot separated from ground for impedance matching in 5 GHz band is etched on 2.4 GHz printed monopole antenna. The proposed antenna is designed and fabricated on a FR4 substrate with dielectric constant 4.3, thickness of 1.6 mm, and size of $30{\times}45mm^2$. The measured impedance bandwidths (${\mid}S_{11}{\mid}{\leq}-10dB$) of fabricated antenna are 270 MHz (2.22 ~ 2.48 GHz) in 2.4 GHz band and 890 MHz (5.08 ~ 5.97 GHz) in 5 GHz band respectively. In particular, high gain of more than about 4 dBi and good omnidirectional radiation patterns have been observed over the entire frequency band of interest.

Genetic and Phenotypic Evaluation of Milk and Fat Production Traits and Their Interrelationship in (Zebu×European) Crossbred Cattle Using Parent Group Mixed Model

  • Singh, D.;Yadav, A.S.;Dhaka, S.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.9
    • /
    • pp.1242-1246
    • /
    • 2003
  • Data pertained to 335 crossbred cows comprising of 1/2 Friesian (F) + 1/2 Hariana (H), 1/2 F + 1/4 Jersey (J) + 1/4 H, 1/2 F + 1/4 Brown Swiss (BS) + 1/4 H, 1/2 F + 1/4 Red Dane (R) + 1/4 H, FR (I) and FRH (I) genetic groups extending over a period of 21 years (1970-1990) maintained at Animal Farm of CCS HAU, Hisar. The averages for first lactation milk yield was $2,486.24{\pm}80.26kg$ and peak yield of first three lactation were $11.35{\pm}0.72kg$, $13.97{\pm}0.60kg$ and $16.02{\pm}0.42kg$, respectively. The lifetime milk production was observed as $11,305.16{\pm}1,004.52kg$ in crossbred cattle. The average first lactation fat yield was observed as $102.06{\pm}0.01kg$ and peak fat yield of first three lactation were $0.458{\pm}0.01$, $0.490{\pm}0.01$ and $0.500{\pm}0.02kg$, respectively. The lifetime fat production was estimated as $502.31{\pm}45.90kg$. LTMP and LTFP had reasonably good additive genetic variance which could be exploited either through mass selection/combined with family or pedigree selection. FLMY, peak yields and LTMP had significant positive phenotypic correlation with FLFY and LTFP and the correlation at the genetic level were also higher and positive for these traits. Finally, peak week milk yield of first lactation (PMY1) was the earliest available trait having desirable and significant correlation at phenotypic and positive at genetic level with FLFY, PFY1 and PFY2, PFY3 and LTFP and selection for this trait will help in early evaluation of sires and dams and will increase genetic advancement per unit of time.

Supplemental Lighting by HPS and PLS Lamps Affects Growth and Yield of Cucumber during Low Radiation Period (약광기 HPS와 PLS lamp를 이용한 오이의 보광재배효과)

  • Kwon, Joon-Kook;Yu, In-Ho;Park, Kyoung-Sub;Lee, Jae-Han;Kim, Jin-Hyun;Lee, Jung-Sup;Lee, Dong-Soo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.400-406
    • /
    • 2018
  • In this experiment the effect of supplemental lighting on the growth and yield of cucumber (Cucumis sativus L. 'Fresh') plants during low radiation period of winter season were investigated in glasshouses using common high-pressure sodium (HPS) lamps and newly developed plasma lighting system (PLS) lamps. Plants grown without supplemental lighting were considered as a control. Supplemental lighting was provided from November 20th, 2015 to March 15th, 2016 to ensure 14-hour photoperiod (natural+supplemental light), also lamps were operated automatically when the outside sun radiation levels were less than $100W{\cdot}m^{-2}$. Spectral analysis showed that HPS lamp had a discrete spectrum, lacked of the radiation in the 400-550 nm wave band (blue-green light), but had a high output in the orange-red region (550-650 nm). A higher red light output resulted in an increased red to far-red (R/FR) ratio in HPS lamp. PLS had a continuous spectrum and had a peak radiation in green region (490-550 nm). HPS has 12.6% lower output in photosynthetically active radiation (PAR) but 12.6% higher output in near infra-red (NIR) spectral regions compared to PLS. Both HPS and PLS lamps emitted very low levels of ultra-violet radiation (300-400 nm). Supplemental lighting both from HPS and PLS lamps increased plant height, leaf number, internode number and dry weight of cucumber plants compared to control. Photosynthetic activity of cucumber plants grown under two supplemental lighting systems was comparable. Number of fruits per cucumber plant (fruit weight per plant) in control, PLS, and HPS plots were 21.2 (2.9 kg), 38.7 (5.5 kg), and 40.4 (5.6 kg), respectively, thereby increasing yield by 1.8-1.9 times in comparison with control. An analysis of the economic feasibility of supplemental lighting in cucumber cultivation showed that considering lamp installation and electricity costs the income from supplemental lighting increased by 37% and 62% for PLS and HPS lamps, respectively.