• Title/Summary/Keyword: FTIR

Search Result 1,367, Processing Time 0.03 seconds

The Design of Efficient User Environment on the FTIR Multi Touch (FTIR 멀티터치 테이블에서 효율적인 사용자 환경 개발)

  • Park, Sang-Bong;Ahn, Jung-Seo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.85-94
    • /
    • 2012
  • In this paper, we develop the new gestures of screen control with fingers on the FTIR multi touch table. It also describes recognition of mobile devices on the table using infrared camera. The FTIR multi touch table was incovenient to the existiog Bluetooth connection, because it is not provided with an HID(Human Input Device) interface. The proposed data transmission method using mobile device is to relieve the inconvenience of the data transfer and proceed more effectively. The new gestures and data transmission method is verified by FTIR multi touch table that is implemented for testing.

A Study on Incompletion of TIR within Acrylate of FTIR Touch Screen (FTIR 터치스크린 아크릴 계면의 전반사 현상 연구)

  • Han, Ji Heum;Han, Won Heum;Yoon, So Young
    • Journal of Adhesion and Interface
    • /
    • v.14 no.2
    • /
    • pp.57-67
    • /
    • 2013
  • The incompletion of TIR (Total Internal Reflection) in FTIR (Frustrated Total Internal Reflection) touch screen has been investigated as follows. Assuming a 3 layer thin film of medium1 ($n_1$)-medium2 ($n_2$)-medium3 ($n_3$) with refraction indices of $n_1=n_3{\neq}n_2$, it was theoretically proven that FTIR or OT (ordinary transmission) phenomena might happen through medium2 from medium1 to medium3 relying on relative difference in $n_1(=n_3)$ and $n_2$, and that the formulae for FTIR and OT could be transformed into each other depending on the number state (imaginary or real) of the light wave phase. In parallel to the theoretical analysis, the incompletion of TIR in acrylate due to external contacts was also elucidated from the experimental and phenomenological viewpoints. On the basis of this considerate work, we explained how to improve the touching performance for better FTIR touch screen.

FTIR Characterization on Treated Gem Stone Sapphires (보석용 처리 사파이어의 FTIR분석)

  • 송오성;이기영;이정임;김민규;최은집
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.17-21
    • /
    • 2003
  • It has been difficult to characterize the value of treated sapphires for gem stones with bare eyes. Color enhancing treatments by diffusion and annealing became sophisticated and customers and gemologists had asked a non-destructive and fast characterization method. We suggest that Fourier transformation infra-red (FTIR) offers to characterize the cobalt-doped synthetic sapphires successfully in 3 minutes. Our results imply that FTIR may be employed in jewelry business to identify the treated sapphires in quantitative way.

  • PDF

FTIR and Moisture Effects on Optical Information Transfer at Interface of Air and Glass (공기-유리 계면에서 광학정보 전달에 미치는 불완전 반사 및 수분 효과)

  • Han, Won Heum;Han, Ji Heum;Kim, Jee Hyen;Jung, Hyung Sik;Lee, Moon Ho
    • Journal of Adhesion and Interface
    • /
    • v.13 no.2
    • /
    • pp.73-84
    • /
    • 2012
  • The transfer mechanism of optical information at the interface of air and glass (the air-glass IF) has been investigated by thoroughly fulfilling the theoretical and experimental analyses regarding the FTIR (Frustrated Total Internal Reflection) and moisture effects on the fingerprint onto a glass cup with water. As for the fingerprint onto a glass cup with water its image was observed to be very vivid, which turned out to be due to the difference between the two light intensities reflected on the air-glass IF and the wet fingerprint ridge by manipulating the optical theories such as Fresnel relation, Snell's law, FTIR, GT (general transmission) and so on. In addition, the experimental inspection for FTIR and moisture effects on the fingerprint image also evidenced the fact that the vivid fingerprint image originated from the moisture effect rather than the FTIR phenomenon.

A study on combustion gas toxicity of polymeric materials using FTIR gas analysis (FTIR 가스분석에 의한 고분자재료의 연소가스독성 평가)

  • Lee, Doo-Hyung;Kong, Young-Kun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.79-84
    • /
    • 2005
  • When polymeric materials are exposed to fire condition, a lot of heat and toxic gases evolved and cause damage to property and human being. Especially toxic gases are major hazard to life safety. This study FTIR(Fourier Transform Infrared) spectrometer analysis was performaed to etermine the gas analysis and the concentration of gases evolved from PVC, FRP, SMC and Ureathane foam using ASTM E 1678 fire model. And FED toxicity index calculated from FTIR data also presented. By the comparison of animal test adopted in KS F 2271 and FTIR gas analysis method, FTIR gas analysis method can replace current animal toxicity test and produce precise and quantitative combustion gas data.

ATR-FTIR Analysis of Adhesives Jointing Buddhist Scripture Scrolls in Medieval Korea(Goryeo Dynasty)

  • Oh, Joon Suk
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.11-18
    • /
    • 2019
  • The adhesives joining Buddhist scripture scrolls from medieval Korea(Goryeo Dynasty, A.D. 918~1392) are different from wheat starch adhesive. The composition of the adhesive was analyzed using Attenuated Total Reflectance-Fourier Transform Infrared(ATR-FTIR) spectroscopy. In the adhesive used to join Buddhist scripture scrolls, peaks attributed to amide I and amide II of the protein and carbohydrate were detected in the ATR-FTIR spectra, and no carbonyl peak($1745cm^{-1}$) for oil was detected in the 2nd derivative ATR-FTIR spectra. The ATR-FTIR spectra almost coincided with those of defatted soybean powder adhesive. Hence, the adhesives joining Buddhist scripture scrolls were inferred to be soybean adhesive prepared from a defatted soybean cake.

Study on the Characteristic due to the Various Polarity based on the Carbon Contents in Organic Thin Film (유기물 박막에서 탄소 함량에 따라서 달라지는 분극의 변화에 따른 특성 변화에 대한 연구)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.9
    • /
    • pp.2065-2070
    • /
    • 2010
  • The diluted PMMA treated $SiO_2$ films as an passivation materials for semiconductor devices was researched by using the FTIR spectra. The diluted PMMA solution with various ratios changed the surface of $SiO_2$ film as the hydrophilic, hydrophobic or hybrid type properties. The sample 7 with little carbon content showed dramatically the chemical variation by the FTIR spectra analysis. Beacuse the little carbon with electrons decreased the polarity and surface energy on the $SiO_2$ film, and then became a stable bonding structure and decreased the leakage current. The FTIR spectra can define the detail variation due to the chemical reaction on the organic thin film, and help to research the characteristic of the organic materials.

Evaluation of Water Absorption Phenomena into the Photo-resist Dry Film for PCB Photo-lithography Process (PCB Photo-lithography 공정에 사용되는 Photo-resist인 Dry Film에 대한 물의 확산 침투 현상평가)

  • Lee, Choon Hee;Jeong, Giho;Shin, An Seob
    • Applied Chemistry for Engineering
    • /
    • v.24 no.6
    • /
    • pp.593-598
    • /
    • 2013
  • In this study, we have evaluated the water absorption phenomenon of photoresist dry film, which is commonly used to build circuits on PCB (Printed Circuit Board) by photolithography, by using ATR-FTIR (Attenuated Total Reflectance-Fourier Transform Infrared). We have firstly observed significant change in fracture mode of dry film with respect to temperature and humidity, which we assumed the material transition from ductile to brittle. Secondly, we have established the process of absorption test for determining the diffusion coefficients of water into the dry film both with gravimeter and ATR-FTIR. We have successfully calculated the diffusion coefficients for each environmental conditions from the results which we achieved by gravimeter and ATR-FTIR. Compared to the gravimeter which is a conventional method for absorption test, the ATR-FTIR method in this study has been found to be very easy to use and have the same accuracy as gravimeter. Moreover, we are expecting to use the ATR-FTIR as an appropriate method to study the absorption phenomena related to any kinds of solvent and polymer system.

Comparison of Analytical Methods for α-Quartz by FTIR and XRD (FTIR과 XRD를 이용한 α-Quartz 분석법 비교)

  • Kim, Boo-Wook;Lee, Jong-Seong;Choi, Byung-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.130-142
    • /
    • 2009
  • This study compared FTIR with XRD method for the analysis of quartz by % recovery, coefficient of variation (CV) and influence of the interference. the results were as the following. 1. In FTIR method, the coefficient of determination ($r^2$) was 0.9998 in a calibration curve of $695\;cm^{-1}$, and the limit of detection was $4.9{\mu}g/sample$. 2. The highest recovery was $799\;cm^{-1}$ (98.2%). 3. The CVpooled of the FTIR method was approximately 10% in three wave numbers. 4. The analysis of qualitative and quantitative for quartz is difficult with mixed cristobalite and iron oxide. 5. In XRD method with rotating sample holder and LynxEye detector, the coefficient of determination was 0.9996 in a calibration curve, and the limit of detection was $5.9{\mu}g/sample$. 6. The recovery and CV pooled were 104.3%, and 11 %, respectively. 7. In muffle furnace ashing, the quartz weight decreased to 34% when the maximum weight of the iron oxide was more than eight times. In conclusion, the accuracy (% recovery) and precision (CV) of FTIR and XRD method for analyzing $\alpha$-quartz were similar. FTIR method was a disadvantage for sample matrix because it indicates possibility of interference. However, XRD method distinguished specific crystalline forms of silica, and the majority of silicate minerals. In addition, XRD method recommend filter dissolution to pretreatment method.

Analysis of sampling noise effect of Interferometer on FTIR Spectrometer (FTIR 분광용 간섭계의 샘플링 잡음 영향 분석)

  • Bae, Hyo-Wook;Park, Do-Hyun;Ra, Sung-Woong;Choi, Seung-Ki
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.10-17
    • /
    • 2007
  • FTIR(Fourier Transform Infrared) spectrometry is a useful method to obtain infrared spectra of materials in gas phase by registering the interferogram of a target material using an interferometer, and then performing a Fourier transform on the interferogram to obtain the spectrum. In this paper, sampling noise effect on signal processing of the rapid scan interferometer was studied with relation to sampling the interferogram points at the improper location and empirically verified.