• 제목/요약/키워드: Failure Mode %26 Effects Analysis

검색결과 5건 처리시간 0.019초

하이브리드 로켓 점화 장치의 신뢰도 예측 (Reliability Prediction of Hybrid Rocket Ignition System)

  • 문근환;문희장;최주호;김진곤
    • 한국항공운항학회지
    • /
    • 제24권4호
    • /
    • pp.26-34
    • /
    • 2016
  • In this study, reliability prediction of the ignition system of hybrid rocket is performed. The FMECA is preceded to the reliability prediction. To this end, the ignition system is divided into 5 components and 19 potential failure modes. The failure cause and effects are identified and criticality analysis is carried out for each failure mode, in which the criticality number is estimated using the failure rate databases. Among the numbers, the failure modes and components with higher criticality and severity are chosen and allocated with higher weighting factor. The reliability predictions are performed using the failure rate databases, from which the current ignition system is found to satisfy the target reliability.

전기집진기 예지보전 단계에서의 고장모드영향분석 (FMEA of Electrostatic Precipitator for Preventive Maintenance)

  • 한승훈;이정욱;이선엽;황종덕;강대곤
    • 해양환경안전학회지
    • /
    • 제26권6호
    • /
    • pp.706-714
    • /
    • 2020
  • 전 세계 90 %의 인구가 WHO의 연평균 미세먼지 노출 기준(10 ㎍/㎥)을 초과한 공기를 흡입하고 있다. 전 세계적으로 육상뿐만 아니라 해양에서 발생하는 질소산화물에 대한 규제를 통해 2차 오염물질, 초미세먼지 저감에 대해 노력하고 있으며 국내에서는 선박에서 미세먼지 발생의 주요한 원인인 황 함유량 저감과 환경친화적 선박의 개발 및 보급 등을 통해 깨끗한 해양환경 조성을 위한 노력을 하고 있다. 디젤엔진 유해 배출가스 저감을 위한 기술 중 압력 손실이 적고 높은 집진 효율 및 NOx의 제거와 유지 관리의 장점이 많은 전기 집진기의 수요와 중요성이 증가하고 있다. 본 연구는 총톤수 999톤급 선박의 2,427 kW 선박용 디젤엔진의 미세먼지 저감을 목적으로 개발된 전기 집진기를 예지보전단계에서 고장모드영향분석을 통해 장비 품질을 높여 선박 내에서의 내구연한을 높이고자 위험 우선순위 도출하였다. 위험 우선순위는 고장모드 241(poor dust capture efficiency)이 RPN 180으로 가장 높았다. Collecting electrode에서 가장 많은 고위험 고장모드를 검출하여 집중관리 부품으로 관리해야 할 필요가 있었으며 원인으로 진동과 핀 풀림으로 인한 유격 불량이 가장 많이 검출되었다. 핀 풀림 역시 근본적으로는 선체 또는 장비에서 발생하는 진동이 원인이 되어 발생할 수 있는 사항이기 때문에 핀 풀림이 발생하는 개소에 보완이 필요하겠다.

Seismic performance of prefabricated reinforced concrete column-steel beam sub-assemblages

  • Bai, Juju;Li, Shengcai
    • Earthquakes and Structures
    • /
    • 제22권2호
    • /
    • pp.203-218
    • /
    • 2022
  • In this paper, quasi-static tests were carried out on three prefabricated reinforced concrete column-steel beam (RCS) sub-assemblages with floor slabs and one comparison specimen without floor slab. The effects of axial compression and floor slab on the seismic performance were studied, and finite element simulations were conducted using ABAQUS. The results showed that the failure of prefabricated RCS sub-assemblages with floor occurred as a joint beam and column failure mode, while failure of sub-assemblages without floor occurred due to beam plastic hinge formation. Compared to the prefabricated RCS sub-assemblages without floor slab, the overall stiffness of the sub-assemblages with floor slab was between 19.2% and 45.4% higher, and the maximum load bearing capacity increased by 26.8%. However, the equivalent viscosity coefficient was essentially unchanged. When the axial compression ratio increased from 0.24 to 0.36, the hysteretic loops of the sub-assemblages with floor became fuller, and the load bearing capacity, ductility, and energy dissipation capacity increased by 12.1%, 12.9% and 8.9%, respectively. Also, the initial stiffness increased by 10.2%, but the stiffness degradation accelerated. The proportion of column drift caused by beam end plastic bending and column end bending changed from 35% and 46% to 47% and 36%, respectively. Comparative finite element analyses indicated that the numerical simulation outcomes agreed well with the experimental results.

Effects of radiation therapy on the dislocation resistance of root canal sealers applied to dentin and the sealer-dentin interface: a pilot study

  • Pallavi Yaduka;Rubi Kataki;Debosmita Roy;Lima Das;Shachindra Goswami
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.22.1-22.12
    • /
    • 2021
  • Objectives: This study evaluated and compared the effects of radiation therapy on the dislocation resistance of AH Plus and BioRoot RCS applied to dentin and the sealer-dentin interface. Materials and Methods: Thirty single-rooted teeth were randomly assigned to 2 groups (n = 15 each): AH Plus (Dentsply DeTrey) and BioRoot RCS (Septodont). Each group was subdivided into control and experimental groups. The experimental group was subjected to a total radiation dose of 60 Gy. The root canals of all samples were cleaned, shaped, and obturated using the single-cone technique. Dentin slices (1 mm) were sectioned from each root third for the push-out test and scanning electron microscopy (SEM) was done to examine the sealer-dentin interface. The failure mode was determined using stereomicroscopy. Bond strength data were analyzed by the independent t-test, 1-way analysis of variance, and the Tukey post hoc test (α = 0.05). Results: Significantly lower bond strength was observed in irradiated teeth than non-irradiated teeth in the AH Plus group (p < 0.05). The BioRoot RCS group showed no significant reduction in bond strength after irradiation (p > 0.05) and showed a higher post-irradiation bond strength (209.92 ± 172.26 MPa) than the AH Plus group. SEM revealed slightly larger gap-containing regions in irradiated specimens from both groups. Conclusions: The dislocation resistance of BioRoot RCS was not significantly changed by irradiation and was higher than that of AH Plus. BioRoot RCS may be the sealer of choice for root canal treatment in patients undergoing radiation therapy.

의료기기 신제품의 인허가정책 규제강도에 연계한 규제대응 프레임워크 수립 및 운영에 관한 연구 - FMEA 적용을 중심으로 - (A Study on the Establishment and Operation of a Regulatory Response Framework in connection with the Regulatory Strength of the Licensing Policy for New Medical Devices -Focusing on the Application of FMEA-)

  • 김교수;류규하;김연희
    • 기술혁신연구
    • /
    • 제28권4호
    • /
    • pp.1-26
    • /
    • 2020
  • 전 세계적인 코로나19의 확산으로 인해, 진단시약 등과 같은 감염병 의료 및 의료기기 신제품이 비약적으로 개발·출시되고 있으며, 이의 빠른 수급을 위해 각 국가들은 수입규제를 완화하거나 신속한 인·허가를 위한 정책을 펼치고 있다(NIDS, 2020). 반면, 신종 감염병과 관련 없는 신개발 의료기기의 경우 오히려 시험검사 등 지연 및 취소되는 사례가 발생하고 있는 등 여전히 엄격한 인·허가규제를 통해 시장에 진출하고 있다. 이에 본 연구는 의료기기신제품이 시장에 진출하면서 마주하게 되는 정부소관법률에 특화하여 규제강도 영향요인을 도출하고 규제강도를 분석하여 규제대응 프레임워크를 제안하였다. 연구방법은 문헌연구, Failure Mode and Effects Analysis(FMEA)기법 적용, 전문가인터뷰(1차):아이디어수집, 전문가인터뷰(2차) : 타당성검증의 방법으로 진행하였으며, FMEA기법의 적용프로세스를 통해 우선 규제단계별 영향요인의 발생영향도와 규제사무 유형별 부담영향도를 곱하여 규제요인의 중요도를 구하고, 규제영향 심각도를 곱하는 방식으로 규제강도 정량화방법을 제시하였다. 시사점은 최근 해외 주요 국가들 및 우리나라 정부가 코로나19에 따른 신개발의료기기의 신속한 인·허가를 위한 특별규제정책 및 완화정책을 펼치며 적극적으로 대응하고 있는 시점에 본 연구에서 제안된 프레임워크를 통해 향후 기존 의료기기 신제품의 인·허가 정책 규제프로세스에도 보다 적극적이며 선제적인 대응이 될 수 있도록 규제의 개선방향과 규제대응 방안이 이루어지길 기대한다.