• Title/Summary/Keyword: Fire Extinguishers

Search Result 46, Processing Time 0.024 seconds

Analysis of the Precautionary Measures and Causes on Explosion Accidents of a Old Dry Chemical Powder Extinguisher (노후 분말소화기의 폭발사고 원인과 예방대책에 관한 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.91-99
    • /
    • 2012
  • Fatal injuries and deaths have occurred resulting from the operation or disassembling of a powder extinguishers in Korea. If a rusted powder extinguisher is exploded during operation or disassembling, it rises to the air like a rocket and hits a head, chest, or neck part of an operator, resulting in his (her) death or injury. In this study examines the explosion accident cases of a powder fire extinguisher and analyzes their causes, reactions to explosion, and precautionary measures. And in this paper suggests 1) no using of old fire extinguishers in fire drill or education, 2) education and public information on danger of old fire extinguishers, 3) indication of explosion danger to cartridge-type dry chemical powder fire extinguishers had already placed to buildings etc., 4) obligatory indication of durable years on fire extinguishers, 5) examination for introduction of system that do hydraulic pressure test about fire extinguishers that given period past, 6) construction of system that reclaim old fire extinguishers, 7) construction of system that recycle or reuse old fire extinguishers, and 8) operation of help desk related to old fire extinguishers as precautionary measure of fire extinguisher explosion accidents.

조사연구-선박용 소화기에 관한 지침

  • Park, Yeong-Geun
    • Fire Protection Technology
    • /
    • s.18
    • /
    • pp.21-27
    • /
    • 1995
  • This paper is aimed to introduce the related marine type fire extinguishers standards between the domestic and the abroad. This is based on the fire extinguishers at chapter 2 -2 Regulation 6. of the International Convention for the Safety of Life at Sea. 1974, and Guidelines for Marine Portable Fire Extinguishers at Internation-al Maritime Organization Annexed Resolution A. 602 (15)

  • PDF

위험관리정보 - 소화기의 선택과 배치

  • Yu, Ho-Jeong
    • 방재와보험
    • /
    • s.106
    • /
    • pp.59-63
    • /
    • 2005
  • 이 글에서는 ISO 11602-1, Fire Protection - Portable and Wheeled Fire Extinguishers - part 1 : Selection and installation(2000년판)과 NFPA 10, Standard for Portable Fire Extinguishers(2003년판)에 설명된 소화기 선택과 배치에 대한 개괄을 한다.

  • PDF

Methods to Improve the Design of Household Fire Extinguishers through an Empirical Analysis of Consumer Compatibility (소비자의 적합성 실증분석을 통한 가정용 소화기의 디자인 개선방안)

  • Lee, Sung-Woo
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.58-66
    • /
    • 2020
  • Households are categorized as exceptions in the Fire Services Act; oftentimes, the 'Golden Time' is missed at the early stages of a fire, resulting in loss of life. As such, due to the high number of deaths caused by household fires, the Korean government amended the Fire Services Act to make it mandatory for all detached houses to be equipped with a fire extinguisher from 2017 onwards. Only 34.8% of households were properly equipped with a fire extinguisher, according to the 2018 factual survey on fire extinguishing facilities in households conducted by the Fire Department. Fire extinguishers are crucial in case of fire but many households avoid them because they are red and have a rough aesthetic, which does not suit the household environment. There is now a need for diverse simple fire extinguisher designs so that they can be used as interior décor in the household in the day-to-day while being available for putting out a fire when necessary. If fire extinguishers have designs that go well with any household space like other decorative ornaments, this will greatly increase consumers' motivation to purchase them. It is greatly anticipated that various companies will work on developing designs for fire extinguishers to commercialize them for households in the future.

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

Study on the Promotion of Recycling of Old Fire Extinguishers (폐 소화기 재활용 촉진 방안에 관한 연구)

  • Jin, Young-Bae;Jung, Myung-won;Oh, Jung-Seok
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.156-163
    • /
    • 2019
  • This study examined the recycling system of a foreign lung excreta system. First, the measures for promoting the recycling of a pulmonary digestive system were as follows. Second, a manual considering specialization, such as the construction of a recycling treatment system of fire extinguishers and the collection, transportation, recycling, publicity, and education of fire extinguishers, were developed. Third, an education and counseling system is needed to overcome the lack of experience and technical support for systematic and safe disposal of pulmonary digestive system. Fourth, to promote the recycling of fire extinguishers in the government and fire extinguisher related organizations, it is necessary to prevent environmental pollution and recycle parts to reduce the waste of resources and improve the fire extinguisher quality by fostering a fire safety industry and policy support.

Research on the Current Status of Installation and Awareness of Fire Extinguishers and Awareness of Fire Extinguishers (일상생활 환경에서의 소화기 비치 실태와 소화기 인식에 관한 연구)

  • Lee, Wonjoo;Kwon, Shin Young;Lee, Chang-Seop
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.26-32
    • /
    • 2015
  • The main purpose of this study is to propose a directionfor fire safety education and to discuss the current issues of fire extinguisher training A survey was conducted, and the results show that only 52.1% of homes have a fire extinguisher, whereas over 93% of public and private work places (e.g., schools and businesses) have a fire extinguisher. Approximately 90% of the survey participants had fire extinguisher training experience. However, only 65.8% of the public and private work places conducted fire extinguisher training regularly. 42.5% of survey participants had not been trained in the past year. In the survey result on fire extinguisher knowledge, participants showed a score of 3.95/5.00 for how to use a fire extinguisher and a score of 3.00/5.00 for the meaning of the ABC ratings of fire extinguishers. An independent T-test showed that the "the installation of fire extinguishers in the house" and "regular fire safety education in your group" have influences on the "the knowledge of fire extinguishers" (p < .05).