Measurement of Ceiling Temperature in Tunnel for Heights and Fire Sizes of Fire Source (화원의 높이 및 화재크기별 터널 천장온도 측정 실험)

  • Park, Won-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.5-10
    • /
    • 2015
  • The "Ondong tunnel" is not used now where is one of the tunnels in the Janghang line which is from Cheonan to Iksan. The length of the tunnel is 214 m. The location of the fire source is center of the tunnel and the pool fire with heptane is for the fire source. Tests are carried out for the various fire sizes, the height and obstructed/open condition of the fire source. Temperature on the top of the tunnel is measured. Even if the fire size is same, the maximum temperature on the ceiling of the tunnel for the elevated fire source is very larger than the maximum for the ground fire source. As the fire size is lager the maximum temperature on the ceiling is higher. These test results can be very useful for design and guidelines of fire detectors in tunnels.

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

Numerical Prediction of Smoke Concentration in a Compartment Fire by Using the Modified Volumetric Heat Source Model (수정된 체적열원모델을 이용한 실내 화재의 연기농도 예측)

  • Kim Sung-Chan;Lee Seong-Hyuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.344-350
    • /
    • 2006
  • The present study investigates the characteristics of fire-driven heat flows and gas concentration in a compartment fire by using the modified VHS model (MVHS). The main idea of this model is to add some source terms for combustion products and oxygen consumption to the original VHS model for providing more accurate and useful information on gas concentration distributions as well as thermal fields. It is found that the present MVHS model shows fairly good agreement with the experimental data and the eddy breakup combustion model. The tilting angle of fire plume calculated by MVHS is larger than that of EBU model because the fire source of VHS is affected by ventilating flow less than EBU. However, this discrepancy is apparently reduced in the downstream region of fire source.

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

Combustion Characteristics of Pool and Whirl Fire on Methanol by Height of Fire Source using the Small Scale (화점높이 변화에 따른 메탄올의 소규모 Pool 및 Whirl Fire의 연소특성)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-78
    • /
    • 2012
  • This study is intended to understand flame behavior of pool and whirl fire by height of fire source. Liquid fuel was methanol which is used in many studies for pool and whirl fire. Size of vessel was $100{\times}100{\times}50$ and the vessel was made by stainless steel. Combustion time, mass loss rate, flame temperature, flame height and air entrainment rate from the outside to flame were measured, and flame behavior was visualized with video camera. Based on the experiment, it was found that combustion characteristics by height of fire source got a more effect on whirl fire than pool fire.

Analysis for fire suppression efficiency of intermittent water spray pattern with FDS (FDS를 이용한 교번식 미분무방식의 소화 성능 분석)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.200-203
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively low and the infiltration of water mist to the fire source is not effective. In addition to lower penetration force, the evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist system is expected to improve the penetration force of water mist as well as the dilution coverage capability with the stratified spray characteristics. At this paper we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis shall be supportive to the development of the prototype of water mist nozzle.

  • PDF

A Study on Fire Characteristics in a Tall and Narrow Atrium

  • Sugawa, Osami;Takahashi, Wataru;Ohtake, Masanori;Satoh, Hiroomi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.353-360
    • /
    • 1997
  • The modeling on fire safety assessment for a tall and narrow atrium is carried out using a reduced and full scale atrium models based on the performances of flow behavior in and near comer fire and smoke ventilation system. The comer (or wall) effects on the flame behavior considering air entrainment into a flame was evaluated theoretically and experimentally. Temperature, upward velocity, inlet air velocity, and pressure difference between the atrium space and atmosphere were measured systematically in a reduced scale model. The performance of the modeling to estimate temperature rise and natural air ventilation volume was verified based on the experimental results. Smoke filling rate from a model fire source set at the center of a tall and narrow atrium is fastest in the other cases in which fire source set in or near a corner. This suggested that the centering of the fire source is acceptable as the fire source position to assess the fire safety design for a tall and narrow atrium.

  • PDF

Mass Loss and Air Entrainment Rate of Whirl Fire by Height of Fire Source (화점높이 변화에 따른 Whirl Fire의 질량감소 및 공기유입속도)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.126-131
    • /
    • 2011
  • This study is intended to understand mass loss rate and air entrainment rate of the whirl fire by height of fire source. Liquid fuels were methanol and n-Heptane which are used in many studies of whirl fire. Size of vessel was 100 mm ${\times}$ 100 mm ${\times}$ 50 mm and the vessel was made by stainless steel. When height of fire source changed from 0 cm to 30 cm, air entrainment rate showed the fastest in case of 0 cm. And in the same height of fire source, average and maximum air entrainment rate showed the fastest in 30 cm of anemometer. From the results of whirl fire for methanol and n-Heptane, mass loss rate and air entrainment rate of n-Heptane was found to faster 1.33 to 1.58 times and 4.38 to 5.44 times compared with methanol, respectively. Consequently, mass loss rate and air entrainment rate in whirl fire was able to identified decrease as height of fire source increases and the higher the heating value, increases the that's value.

A Study on the Adaptability of the CO Sensor as A Fire Detection Sensor According to the Test Fire Source of UL 268 (UL 268 시험화원에 따른 CO센서의 화재감지센서로서의 적용성에 관한 연구)

  • Lee, Chun-Ha;Sung, Want-Ki;Lee, Jong-Hwa;Kim, Hyeong-Gweon;Jee, Seung-Wook;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.54-63
    • /
    • 2014
  • The purpose of this study is to test the adaptability of the CO sensor as a fire detector by analyzing its sensing characteristics on fire. In order to test the applicability, we designed and made a fire testing ground whose size is similar to that regulated by UL 268, carried out real fire tests suggested by UL 268, and conducted a comparison analysis on the sensing characteristics between the CO sensor and a photoelectric smoke detector by different types of fire source. The experiment result to the sensing characteristics of the CO sensor is about twice to three times faster than that of the photoelectric smoke detector, proceeding with incomplete combustion such as paper and wood fire source in the initial fire. Especially in case of wood smoldering fire, sensing characteristics of the CO sensor is very excellent.

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.