• Title/Summary/Keyword: Fire detection tendency

Search Result 3, Processing Time 0.017 seconds

Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors (실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구)

  • Choi, Su-Gil;Young, Jin-Se;Park, Sang-Min;Nam, Yeong-Jae;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.37-46
    • /
    • 2020
  • This is a basic research on potential application of fire detection by measuring fire detection tendency of indoor air quality measurement factors. In this study, operation experiment using smoke detector sensitivity tester and paper fire experiment specified in UL 268 standards were conducted to evaluate the fire detection tendency of indoor air quality measurement factors. Based on the cross-substitution of values measured in the paper fire experiment, PM10 (excluding average) and HCHO (excluding average and maximum) for the indoor air quality meter (IAQ); PM1.0, PM2.5, and PM10 for IAQ S2; and CO (excluding the average and maximum) for combustion gas analyzers showed consistent tendency despite changes in the measured values for smoke generation under all experimental conditions. In particular, PM10 and CO are considered the most applicable fire detection factors among the factors measured in the experiment.

An Experimental Study on the Behavior of Liquid Fuel Flames in the Confined Space (밀폐공간에서 액체연료 화염의 거동에 관한 실험적 연구)

  • Jeon, Kil Song;Hwang, Ji Hyun;Lee, Tea Won
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.87-93
    • /
    • 2021
  • Modern society shows rapid growth that is different from that of the development of existing technologies. The development of these technologies has led to the tendency of buildings to become dense, large and advancing. Regarding fire hazards, the possibility of large-scale fires causing fatal damage, due to the rapid spread of fire, increases. Therefore, for this reason, fire defense, i.e. detection and fire extinguishing facilities, in buildings are essential and well applied. But there are always limitations to that. Based on this reason, we would like to suggest the introduction of a new concept of a fire safety system. The method presented here is not only to use a single system for fire detection and fire extinguishing systems but to jointly use it in the environment and energy management fields within the building. However, an important step is required before introducing a system of these technologies. The fire extinguishing method proposed by this system is a method of extinguishing by blocking oxygen flowing into the space where the fire occurred. However, a sufficient basis is needed for this system to be applied in practice. Therefore, in this study, we intend to conduct a preliminary experiment to introduce the new concept of fire detection and extinguishing. The experiment used ethanol with a relatively simple combustion reaction and a high possibility of complete combustion. As a result, it was confirmed how the internal values changed during a fire using ethanol. Resultingly, we obtained the internal oxygen concentration and internal environmental changes according to the initial flame size. Lastly, the data accumulated in this study can be used as data for application in an automatic fire extinguishing system.

Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study (특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구)

  • Kim, Ki-Hong;Hong, Ki-Jeong;Haam, Seung-Hee;Choi, Jin-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • In Chemical, Biological, Radiological and Nuclear (CBRN) disaster, integrated and optimized equipment package including stretcher, isolation unit, patient monitoring and treatment equipment is essential to achieve proper treatment and prevent secondary contamination. The purpose of this study was to evaluate the efficiency and ease of use of integrated CBRN disaster equipment package for disaster medical response. This study was a randomized crossover study using a manikin simulation for emergency medical technitian (EMT). All participants used the existing devices and prototype of integrated CBRN disaster equipment package alternately. Efficiency was measured by time from vital sign change to detection or treatment application. Ease was use was measured by questionnaires for each patient monitor, stretcher care and isolation unit. 12 EMTs were enrolled. hypoxia-detection time of integrated equipment group was significantly shorter than existing equipment group (4.9 s (3.8-3.9) vs 3.5 s (2.5-3.9), p < 0.05). There was decreasing tendency of ECG change detection and facial mask oxygen supply but no statistical significance was observed. Overall satisfaction of patient monitoring device in integrated equipment group was significantly higher than existing devices (4(3.5-5) vs 3(3-3), p < 0.05). The use of integrated CBRN disaster equipment package shortened the hypoxia detection time and improved usability of vital sign monitor compared to existing devices.