• Title/Summary/Keyword: Firefighting facilities

Search Result 39, Processing Time 0.028 seconds

Study of Indirect Attack Method of Aerial Fire Firefighting by Helicopter on Forest Fire (헬기에 의한 산불공중간접진화 방법에 관한 연구)

  • Bae, Taek-Hoon;Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.24 no.3
    • /
    • pp.55-61
    • /
    • 2016
  • Among the method of aerial fire firefighting, the indirect attack is efficiency way to protect main facilities and it is the aerial fire line construction. According to this study is suggested the fire line construction strategy of indirect attack by helicopter suitable Korea forest fire on theory consideration of indirect attack and experience in practical scene. This study defined that main key points of the fire line construction are accuracy, large quantity, and quickness. Main protection facilities are devided as caution area, warning area, danger area and concern area. Also, it suggested stage-by-stsge from 1 step to 3 step for the aerial fire firefighting correspondence strategy and the fire line construction model. I regard that this study's indirect attack method of the aerial fire firefighting of the fire line construction may be understand about indirect attack tactics and application of indirect attack which is assistance to raise of capability of the aerial fire firefighting with effectiveness and efficiency.

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

A Study on the Necessity and Contents of the Installation Criteria of the Fire Suppression Education & Training Facilities (화재진압 교육훈련시설 설치기준의 필요성 및 내용에 관한 연구)

  • Song, Woo Seung;Ham, Seung Hee;Yoon, Myung O
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.62-71
    • /
    • 2014
  • The importance of the firefighting education & Training is being magnified in order to enhance and strengthen a firefighters' ability and to reduce the firefighters' fatality and casualty. Therefore, It is needed to expand the facilities. In this study, with a comparative analysis of the global firefighting education & training facilities for fire suppression, we try to present the necessity and the basic contents of the establishing the installation criteria for the domestic firefighting education & training facilities. It has to contain specific purpose of the training and minimum standards for the structures with a guarantee of an international level. Naturally, the top priority is a safety of trainees and trainers. And, it should pay attention to a higher effectivity of the training course with a active reflection of the standard operation procedures' scenarios. Simultaneously, by securing a similarity and a compatibility to the other standards, it must maintain the balance of a whole standard.

Study on the Status of Fire Safety Management in Elderly Welfare Facilities (노인복지시설의 소방안전관리실태에 관한 연구)

  • Ko, Wang-Youl;Hur, Man-Sung
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.108-115
    • /
    • 2018
  • Elderly welfare facilities are extremely susceptible to mass casualties in disastrous situations, such as fire, due to the limited physical and mental abilities of their residents. This study examined the status of fire safety management, including the structural problems of elderly welfare facilities, problems of the installation and management of firefighting systems, and problems regarding of fire safety managers. After the Sejong Medical Welfare Facility fire, these problems have been complemented by retrofitting firefighting systems in accordance with the revision of the relevant laws and regulations. On the other hand, the overall status of fire safety management is still insufficient. Therefore, it is important to improve the stability of buildings and firefighting systems as well as fire safety management through additional revision of the relevant laws and regulations.

A Research on the Improvement & Actual Situation of Duplicated Safety Inspections for Facilities (시설별 안전점검 중복성에 대한 실태조사 및 개선방안 연구)

  • Park, Jongkeun;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.53-59
    • /
    • 2017
  • Safety inspection activities of the facilities including the electricity, gas, building, and firefighting, etc. are individual checks by the separate law of each government department, comprehensive inspections for the specific managed facilities or during a weak season, and national safety overall diagnostics for the disaster prevention. Thus, types of the inspections are various and they have been carried out repeatedly as well as duplicately. That can make the people or institutes to take such inspections feel great burdens. Therefore, the investigation on the current situation of the individual inspection by the separate law for the electricity, gas, building, and firefighting, etc. as well as of various others by the government needs to be carried out and according to the results the repetitive and duplicated inspections should be reduced and converged to one comprehensive one. In this regard, we proposed solutions to improve the government safety inspection system, function, and role.

Establishment of Fire-Safety System that combines BIM technology for fire safety with drones and IT convergence technologies (화재안전을 위한 BIM기술과 드론 및 IT융복합 기술을 접목시킨 소방안전시스템 구축)

  • Kim, Dae-Geon;Lee, Gi-Hwi;Hong, Il-Hyeok;Kim, Min-Sung;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.175-176
    • /
    • 2018
  • While damage caused by fire increases, awareness of fire is still low. Morever, Small fires often spread into big fires as they fail to keep the golden time due to the delay in initial response. In particular, the initial response is more important in areas where many unauthorized buildings are called " Panjachon " as firefighting facilities are insufficient compared to other residential facilities. Therefore, we will combine BIM technology, drones and IT convergence technologies to develop a firefighting safety information system that can speed up initial response and help combat fires.

  • PDF

The Effect of the Performance of Firefighting Construction Supervision Personnel on the Completion Inspection of Firefighting Facility Construction in Apartments (소방공사감리원의 업무수행능력이 아파트 소방시설공사의 완공검사에 미치는 영향)

  • Kim, Sang-Sig;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.43-54
    • /
    • 2019
  • In this study, results of completion inspection are investigated according to the performance of the firefighting construction supervision personnel and according to the necessity of clean air supply in a performance test of the firefighting construction supervision personnel. The results of the completion inspection are measured and the causes of defects in the fire protection facilities after issuance of a completion inspection certificate are analyzed. The findings of this investigation can be used to minimize the risk of apartment fires and improve the performance of firefighting construction supervision personnel. The results of this study are summarized as follows. First, the results of the completion inspection conducted by the firefighting construction supervision personnel varies according to particular occupation. The performance of fire facility supervisors from design companies and fire construction companies were significantly higher than the fire officers. Therefore, it is necessary to employ supervisors who have experience in supervising the construction of apartments, in order to improve the performance of fire construction supervision officers. Second, the analysis of the completion inspection results according to the necessity of a clean air supply for performance tests of firefighting construction supervision personnel showed that the necessity of a clean air supply was significantly higher for fire facility supervisors from design companies and fire construction companies than for the fire officers. In order to improve, the completion inspection should be carried out up until the completion date of the building. In addition, a system needs to be established to ensure that clients are not able to demand that a completion inspection certificate be issued on the construction completion date. Finally, it is found that defects of completion inspection after issuance of a completion inspection certificate affects the result of the completion inspection. The results of the completion inspections conducted by the fire facility supervisors from design companies and fire construction companies were affected significantly less by defects than that of the general contractors. Research shows that faults have occured in firefighting facilities after the issuance of a completion inspection certificate due to the client and the construction company demanding the issuance of the completion inspection certificate.

A Study on the Revision of the Fire Safety Standard of the Fire Department Connection (연결송수관설비 화재안전기준(NFSC 502) 개정에 관한 연구)

  • Jang, Gyeong-Nam;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.67-76
    • /
    • 2018
  • Among the firefighting facilities, the fire department connection during firefighting is more important than any other facilities at the firefighting site to supply fire water. This study examined the water supply port of a fire department connection installed at an apartment building based on the Standard for Fire Safety (NFSC 502). The time of discovery was measured by fire fighters who knew or did not know of the water supply port installed in the apartment building, and by separating day and night. To maximize the use of the fire department connection which is the full fire extinguisher facility used by the fire brigade based on the results of the experiment, the author suggests improvement proposals that can clarify the installation location and install the location sign of the fire department connection for the Standard for Fire Safety (NFSC 502).

A Study on Fire and Disaster prevention for Wooden Architecture Heritage: Focusing on the Wooden Catholic Secondary Station in Dangjin (목조건축유산 화재와 방재에 관한 연구: 당진지역 목조 공소건축을 중심으로)

  • Lee, Sanghee
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.4
    • /
    • pp.15-21
    • /
    • 2021
  • This study aims to derive the problems of firefighting and safety measures for architectural heritage with a wooden structure in rural areas and present their improvement measures. To identify those problems, this study grasped the features of the cultural heritage through the building structure and environment of a wooden Catholic secondary station in Dangjin, and analyzed fires that may occur and safety factors. As a result, although the mission station is an important cultural property in terms of its history, place and local identity, it had problems with disaster prevention systems such as vulnerable safety including fire and difficulties in fire recognition and initial firefighting. Therefore, this study concluded through its review and analysis that a disaster prevention system such as stronger firefighting is needed; that fire fighting facilities suitable for the characteristics of the secondary station with a wooden structure should be installed and a main player should be arranged in fire prevention activities to improve the fire prevention system of the cultural property; and that as most mission stations are located in rural areas, it is necessary to more thoroughly protect wooden-structure secondary stations from natural disasters such as forest fire and to improve fire response measures.