Search Result 57, Processing Time 0.032 seconds

Development of Self-controlled gate (무동력 자동 수문 개발)

  • Chung, Kwang-Kun;Chun, Man-Bok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.57-60
    • /
    • 2002
  • Developed power off automatic stanch that keep floodgate upper stream water level changelessly for curtailment of operation by manpower and electricity lead-in equal early investment expense that manual system floodgate and electric motion floodgate have. Human strength does not need in floodgate operation as that power off automatic floodgate open and close floodgate automatically by buoyancy and also, another thing power does not need. Before establish floodgate, effect that get to waterway when behaves repair calculation of correct waterway and decide size of floodgate accordingly and establish floodgate must do examination analysis fussily. power off automatic floodgate night soil that get between countermeasure is the urgentest low-down in reply because can do mistake in operation by phenomenon and so on about water resources by different plate shape change through a model experiment examine closely need to.

  • PDF

Design of Optimal Locating Point of the Hydraulic Cylinder Actuating a Roller-Link Type Rotating Floodgate (콤플렉스법에 의한 롤러-링크 부착형 전도수문 구동용 유압실린더의 최적 설치점 설계)

  • Lee, S.R.
    • Journal of Drive and Control
    • /
    • v.9 no.3
    • /
    • pp.29-36
    • /
    • 2012
  • The hydraulic cylinder is used for actuating the roller-link type rotating floodgate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to the limited space and determined to minimize the cylinder force necessary for actuating the floodgate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the support link. Therefore there exist three design variables to be determined to minimize the cylinder force within the rotating range of floodgate. First, the mathematical model of the roller-link type rotating floodgate is derived to find the cylinder force corresponding to the floodgate angle. Then, the optimal locating point of hydraulic cylinder is searched using the complex method that is one kind of constrained direct search method.

Earthquake Analysis of Dam Floodgate Using Calibrated Added Mass (보정된 부가질량을 이용한 댐 수문의 지진해석)

  • Bea, Jung-Ju;Kim, Ho-Seung;Kim, Yong-Gon;Lee, Jee-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.31-40
    • /
    • 2009
  • In this paper, a trial-error based method is presented to calibrate added mass models through numerical iterations minimizing the difference between the measured frequency data and its numerical simulation result for a dam floodgate. Earthquake analysis of the real floodgate for which the on-site hammering vibration test is performed show that the classical Westergaard added mass model gives relatively larger values in the maximum earthquake force and the maximum total displacement than the present added mass model, based on the calibration of on-site measurement data.

Development of Water Supply System for Water Demand (물수요중심 용수공급 시스템 개발)

  • Chung, Kwang-Kun;Lee, Kwang-Ya;Kim, Hea-Do;Lee, Jong-Nam
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.85-90
    • /
    • 2005
  • A Water Level gauge which composes a water supply system for water demand, information transmission system and the solar storehouse electromotive floodgate, regarding the structure plan and a production of the nothing power automatic floodgate it described. The important point must solve but urgently will compare the water amount used from system establishment place or not one. and It must give proof the efficient characteristic of system, must solve the technical problem portion against revision of the accuracy of upper downstream canal which is information transmission system of the Self-controlled check gate. The solar floodgate is more economic with the base which will reach and the system construction which is accurate.

  • PDF

The Analysis of Damage Characteristic and Cause on Infrastructures by Typhoon (시설물별 태풍에 따른 피해특성 및 원인분석)

  • Shin, Chang-Gun;Lee, Jong-Young;Kim, Seok-Jo;Ji, Young-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1602-1610
    • /
    • 2005
  • In this study was investigated and analyzed of damage characteristics for infrastructures by typhoon that have been many occur. The objective Structures were the road and hydraulic structure. The road structure was included the cut-slopes, retaining walls and bridges. The hydraulic structure is divided with the dike, small-scale dam, reservoir and floodgate. The analysis result of the bridge damage cause is river bottom height increase and passage ability decrease. The principal damage reasons of the cut-slope structure are weakening the ground due to the localized torrential downpour and drainage defective. Also, the principal damage reasons of the small-scale dam, reservoir, dike and the floodgate are continuous collapse of dike beside the floodgate.And we divided a typhoon damage occurrence cause with artificial and natural. As the result of analysis, the many damage occurrence cause will be removed by system improvement and technical development.

  • PDF

Variations of Physical Oceanographic Environment Caused by Opening and Closing the Floodgate in Nakdong Estuary (수문개폐에 따른 낙동강 하구둑 하류부의 해양물리환경변화)

  • Kim Ki-Cheol;Yang Han-Soeb;Kim Cha-Kyum;Moon Chang-Ho;Jang Sung-Tae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.49-59
    • /
    • 1999
  • Nakdong Estuary is complex water system, where sea water and fresh water meet each other. After construction of Nakdong River Barrier, the flow pattern and mixing processes have been changed. Variations of physical oceanographic environment in Nakdong Estuary due to opening and closing the floodgate of Nakdong River Barrier are analysed focusing the movement of outflows from the barrier. Surveys and analysis were made for the three cases. 1. Ordinary times (opening and closing the gate by the tidal period) 2. A period of flood time (opening the gate) 3. A period of water shortage (closing the gate).

  • PDF

A Study of the Vibration of an Axial Flow Pump through FSI Analysis Method (유체-구조 연성해석을 통한 축류펌프의 진동 연구)

  • Lee, Bo-Ram;Yun, Tae-Jong;Oh, Won-Bin;Lee, Chung-Woo;Kim, Hak Hyoung;Jeong, Yeong Jae;Kim, Ill-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.107-112
    • /
    • 2021
  • Pressure, which is a dynamic characteristic of a floodgate, is predicted using an FSI analysis method. A fluid analysis model and a hydrology analysis model were used as analysis models. As a result of the analysis, we found that a warped model has smaller acceleration than a square model. Additionally, this numerical analysis technique was applied to the actual hydrology, and the analysis results were compared with the results of the vibration tests. As a result, we confirmed that there is a small difference between the results of the vibration tests and the results of the FSI analysis. Through this analysis, the applicability and reliability of the FSI analysis method were verified. We concluded that the pressure of a floodgate can be measured through an FSI analysis method.

Prediction of water quality change in Saemangeum reservoir by floodgate operation at upstream (상류제수문 방류조건에 따른 새만금호의 수질변화 예측)

  • Kim, Se Min;Park, Young Ki;Lee, Dong Joo;Chung, Mahn
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.6
    • /
    • pp.373-386
    • /
    • 2017
  • This study simulated water quality item and flow rate of subbasin for Saemangeum watershed using Soil and Water Assessment Tool (SWAT) model and Environmental Fluid Dynamics Code (EFDC) model which simulate hydraulic and water quality in three-dimensions. The simulated values corresponded to observed value well. The result of simulation for floodgate operations at the M3 and M5 points, it exceeds water quality standard and at the M3 and D3 points, change of range for concentration is too wide, and upstream of Saemangeum reservoir is sensitive to inflow flow rate. Compared to the annual average concentration for observed station according to the discharge conditions, improvement of water quality for upstream was apparently compared to the downstream. Range of influence for change of water quality presented that maximum discharge condition, the influence range is 22 km in the direction of the Saemangeum downstream from the Mankyung bridge, and 15 km in the downstream direction of saemangeum in the Dongjin bridge. This study result demonstrated that floodgate operating at upstream has significant influence on water quality management of Saemangeum reservoir and it needs to be considered in plans of water quality management for Floodgate operation on Saemangeum reservoir.

The estimation of water level fluctuation in the down stream water mark by water level fluctuation in the upper region water mark (상류지점 수위표 수위변동에 따른 하류지점 수위표 수위변동예측)

  • Choi, Han-Kuy;Lim, Yoon-Soo;Baek, Hyo-Seon
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.83-89
    • /
    • 2010
  • Generally, the accuracy of the prediction of flood elevation is difficult to identify due to the sedimentation on a river bed, earth and sand being moved by flow, and localized torrential downpours caused by climate change. It is also because of natural and artificial influences on rivers. To predict river floodings successfully, more precise and reliable flood elevation prediction system is needed, in which the concentration time of downstream is numerically interpreted through analyzing and utilizing the watermark of the upper region. Therefore, this research analyzed the prediction methods of the changes in water levels, which use the watermarks of the upper region. The watermarks which impacts the spot being predicted of flood was selected through floodgate analysis and correlation analysis. With the selected watermarks, a statistically reliable regression equation was yielded.

  • PDF