• 제목/요약/키워드: Fluoropolymer

검색결과 38건 처리시간 0.026초

Mechanical and durability properties of fluoropolymer modified cement mortar

  • Bansal, Prem Pal;Sidhu, Ramandeep
    • Structural Engineering and Mechanics
    • /
    • 제63권3호
    • /
    • pp.317-327
    • /
    • 2017
  • The addition of different types of polymers such as SBR, VAE, Acrylic, etc. in concrete and mortar leads to an increase in compressive, tensile and bond strength and decrease in permeability of polymer modified mortar (PMM) and concrete (PMC). The improvement in properties such as bond strength and impermeability makes PMM/PMC suitable for use as repair/retrofitting and water proofing material. In the present study effect of addition of fluoropolymer on the strength and permeability properties of mortar has been studied. In the cement mortar different percentages viz. 10, 20 and 30 percent of fluoropolymer by weight of cement was added. It has been observed that on addition of fluoropolymer in mortar the workability of mortar increases. In the present study all specimens were cast keeping the workability constant, i.e., flow value $105{\pm}5mm$, by changing the amount of water content in the mortar suitably. The specimens were cured for two different curing conditions. Firstly, these were cured wet for one day and then cured dry for 27 days. Secondly, specimens were cured wet for 7 days and then cured dry for 21 days. It has been observed that compressive strength and split tensile strength of specimens cured wet for 7 days and then cured dry for 21 days is 7-13 percent and 12-15 percent, respectively, higher than specimens cured one day dry and 27 days wet. The sorptivity of fluoropolymer modified mortar decreases by 88.56% and 91% for curing condtion one and two, respectively. However, It has been observed that on addition of 10 percent fluoropolymer both compressive and tensile strength decreases, but with the increase in percentage addition from 10 to 20 and 30 percent both the strengths starts increasing and becomes equal to that of the control specimen at 30 percent for both the curing conditions. It is further observed that percentage decrease in strength for second curing condition is relatively less as compared to the first curing condition. However, for both the curing conditions chloride ion permeability of polymer modified mortar becomes very low.

발수발유 가공처리가 폴리에스테르 직물의 표면 특성에 미치는 영향 (The Effects of Water-and Oil-Repellent Finishes on the Surface Characteristics of Polyester Fabrics)

  • 하희정
    • 대한가정학회지
    • /
    • 제35권3호
    • /
    • pp.275-286
    • /
    • 1997
  • The effects of water-and oil-repellent finishes on the surface characteristics of polyester fabrics were investigated in this study. Three kinds of fluoropolyment were selected as water=and oil-repellent finishing agents. The effects of water-and oil-repellent finishes were determined by the water repellency and oil repellency. The surface properties of untreated and treated polyester fabrics were evaluated with respects to crease resistance, contact angle and wicking time. The results of this study were as follows: 1. The polyester fabrics treated with fluoropolymers showed much higher water repellency and oil repellency than those of untreated polyester fabrics. Water-and oil-repellency of fabrics were increased with the crystallinity and the hydrophobic-hydrophillic components of fluoropolymers. 2. Water repellency of fabrics treated with fluoropolymer with hydrophobic components was the highest. Oil repellency of fabrics treated with fluoropolymer with high crystallinity was the highest. Water-and oil-repellency of fabrics treated with fluoropolymer with hydrophyllic components was low comparatively. 3. The crease resistance of polyester fabrics treated with fluoropolymer nearly approached to that of untreated polyester fabric. 4. The water-and oil-repellent finishes improved contact angle markedly. Especially the contact angle of ployester fabric treated with fluropolymer with hydrophobic component was the biggest. 5. The wicking time of polyester fabric treated with fluropolymer with hydrophobic component was the longest.

  • PDF

다기능성 함불소고분자/Blocked-HMDI 블렌드계의 가교화 반응에서의 촉매 영향 (Catalyst Effects on Cross-linking of a Multi-Functional Fluoropolymer/Blocked-HMDI Blends)

  • 안원술
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2408-2413
    • /
    • 2012
  • 불소를 함유하는 다기능성 함불소고분자의 가교화 반응을 위하여 페놀로 blocking된 HMDI를 사용하고 반응의 촉진을 위하여 주석계 촉매(stanous catalyst)를 사용하여 DSC 및 TGA를 사용하여 반응에 미치는 촉매의 영향을 살펴보았다. 용매 및 HMDI의 blocking제로 사용된 페놀이 약 $150^{\circ}C$에 이르기까지 해리되면서 휘발하게 되고 $230-250^{\circ}C$ 온도에서 가교 생성반응이 이루어지는 것이 관찰되었다. 촉매의 농도에 따른 반응기구의 변화는 없는 대신 촉매가 도입될 경우 100배 이상 빨라지는 급격한 반응속도의 변화가 관찰되었으며, 이에 따른 활성화 에너지는 비촉매계에 대한 81.8 kJ/mol로부터 1 phr 촉매계의 대하여 61.7 kJ/mol까지 감소하는 것이 관찰되었다.

Solution-processed electrophosphorescent devices with a thin fluoropolymer at the hole transport interfacial layer

  • Park, Jae-Kyun;Hwang, Gyoung-Seok;Lee, Tae-Woo;Chin, Byung-Doo
    • Journal of Information Display
    • /
    • 제12권4호
    • /
    • pp.223-227
    • /
    • 2011
  • Electrophosphorescent devices with ionomer-type hole transport layers were investigated. On top of the 3,4-ethylenedioxy thiophene:poly(4-styrene sulfonate) [PEDOT:PSS] structures, fluoropolymer interfacial layers (FPIs) with different side chain lengths were introduced. Both for the PEDOT:PSS/FPI (layered) and PEDOT:PSS (mixed) structures with soluble phosphorescent emitters, the short-side-chain FPIs showed higher efficiency. The difference in the electrical properties of the two FPIs for bipolar (light-emitting) devices was not clear, but the hole-only device clearly showed the favored hole injection at the PEDOT:PSS/FPI structure with a shorter side chain, a copolymer of tetrafluoroethylene and sulfonyl fluoride vinyl ether.

국내하수처리장 자외선소독조 운영실태 및 기술동향 (WTP UV Disinfection System)

  • 이진영;김영태;이태제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.126-132
    • /
    • 2005
  • UV disinfection system allows the disinfection of municipal and industrial water and wastewater without the use of expensive chlorination and dechlorination techniques, labor intensive equipments In traditional ultraviolet systems the UV lamps are seperated from water by quartz sleeves. quartz is one of. the few materials that is virtually transparent to UV light, the UV lamp is placed inside the Quartz sleeve. UV light from the lamp is passed through the quartz and into the water, thereby providing disinfection. In fluoropolymer tube-used non-contact UV systems, the water flows through fluoropolymer plastic tubes. banks of UV lamps surround these tubes such that each tube gets exposed to ultra violet light from all sides. in non-contact design the lamps operates at almost constant temperature. this design is extremly efficient in the utilization of UV energy and superior to conventional contact- systems.

  • PDF

열-전기 병합 에너지 생산 겸 자체 냉각 온실 (Energy Generating Self-cooling Greenhouse)

  • ;정모;김종성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.584-587
    • /
    • 2006
  • An energy generating greenhouse based on fluoropolymer envelope and fresnel lens is proposed. The outstanding properties of the fluoropolymer films make them very suitable for large scale solar applications. Extremely high optical transmission over the whole solar spectrum, combined with mechanical strength, and durability allows us to design a highly optimized greenhouses for both plant growing and energy generation. Systems such as photovoltaic triple junction cells are especially attractive since they have up to 35% efficiency with much less cell material when the sun beam is focused with concentrators such as fresnel lenses. Cooling such devices will enhance the efficiency and provide useful thermal energy that could be further utilized for various applications depending on the local demands. This article introduces the basic ideas and principles of the energy generating greenhouses as a first step towards the actual deployment of such systems under Korean environment.

  • PDF

다양한 환경에서 감마선으로 조사된 불소고분자 필름들의 구조 및 열적/물성 변화 (Changes in the Chemical Structure and the Thermal/Physical Properties of Fluoropolymer Films Induced by Gamma Irradiation under Various Environments)

  • 최지선;손준용;신준화
    • 폴리머
    • /
    • 제38권4호
    • /
    • pp.457-463
    • /
    • 2014
  • 본 연구에서는 다양한 환경에서 방사선 조사된 불소고분자 필름(PTFE, FEP, PFA, PVDF 및 ETFE)들의 화학 구조 및 물성 변화를 관찰하였다. 방사선은 $Co^{60}$ 감마선을 사용하였으며, 공기 분위기와 질소 분위기 및 진공 상태에서 조사하였다. 방사선 조사된 불소고분자 필름의 FTIR 분석을 통하여 방사선에 의해 생성된 라디칼이 공기 중 산소와 반응하여 산화반응이 진행되었음을 확인하였다. 또한 DSC를 이용하여 방사선 조사에 의해 변화되는 불소고 분자의 용융열 및 결정화도를 관찰하여 고분자 구조에 따른 절단 및 가교반응을 확인하였다. 인장 강도 실험을 통하여 방사선 조사 환경에 따른 불소고분자의 물성 변화를 관찰한 결과 공기 분위기에서 조사된 불소고분자 필름들의 기계적 물성이 현저히 떨어지는 것을 관찰하였다.

Degradation of Coatings under Atmospheric Tropical Conditions

  • To, Thi Xuan Hang;Pham, Gia Vu;Vu, Ke Oanh;Trinh, Anh Truc;Kodama, Toshiaki;Tanabe, Hiroyuki;Taki, Tohru;Nagai, Masanori
    • Corrosion Science and Technology
    • /
    • 제2권5호
    • /
    • pp.207-211
    • /
    • 2003
  • The weather resistance of five coatings systems based on alkyd, chlorinated rubber, epoxy, polyurethane and fluoropolymer were studied by natural exposure test and accelerated test. The coatings were exposed at Hanoi station with urban industry atmosphere and at Baichay station with marine atmosphere. The degradation of coatings was evaluated by gloss measurement and surface analysis by scanning electronic microscopy. The results obtained show that among coatings tested the gloss of polyurethane and fluoropolymer coatings remained highly and those of alkyd, chlorinated rubber and epoxy coatings were very low after two years of atmospheric exposure. Under accelerating conditions the gloss of fluoropolymer coatings remained highly after 80 cycles of testing. By comparison with accelerating test in UV-condensation chamber the conditions at atmospheric stations are more aggressive.

모의시험에서 정공 주입층 물질 AF의 에너지 갭이 OLED의 전기적 특성에 미치는 영향 (Effect on Electrical Characteristics of OLEDs According to Energy Gap for HIL of Amorphous Fluoropolymer Materials by Simulation)

  • 한현석;김정식;김원종;이종용;소병문;김태완;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.33-33
    • /
    • 2010
  • Electrical properties of organic light-emitting diodes (OLEDs) were simulated by S.co's program. The OLEDs have stable operating parameters, high luminance, and high efficiency in simulation. The AF stands for amorphous fluoropolymer in simulation, and it was used as a hole-injection layer. In the five structure of OLEDs, an AF layer is sandwiched between the hole-transport layer and the ITO layer to increase the external quantum efficiency. By considering organic light-emitting diodes using an optimal energy gap of AF, it could contribute to the improvement of the efficiency of the device in the simulation.

  • PDF