• Title/Summary/Keyword: Foil arrangement

Search Result 4, Processing Time 0.018 seconds

Influence of Jet Nozzle Arrangement on the Performance of a Coanda Foil (제트 노즐의 배치가 콴다 날개의 성능에 미치는 영향)

  • Seo, Dae-Won;Kim, Joung-Hyun;Kim, Hyo-Chul;Lee, Seung-Hee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.569-578
    • /
    • 2008
  • The Coanda effects demonstrate that a jet stream applied tangential to a curved surface can generate lift force by increasing the circulation. Many experimental and numerical studies have been performed on the Coanda effect and it is found to be useful in various fields of aerodynamics. The Coanda effect may have practical application to marine hydrodynamics since various control surfaces are being used to control behaviors of ships and offshore structures. In the present study, numerical computations are performed to find the applicability of the Coanda effect to the marine control surfaces. For the purpose, changes in flow characteristics around a flapped foil due to the Coanda effect have been simulated by RANS equations discretized with a cell-centered finite volume method (FVM). In the process, special attention has been given to the influence of jet nozzle arrangement on the lift characteristics of the Coanda foil. It is found that the shape as well as the location of the jet intake and jet exit affects the lift performance of the foil significantly.

Experimental Study on Hydrofoil Arrangement and Longitudinal Moment Characteristics for Navigation Safety of High Speed Craft (고속선 운항 안정성을 위한 수중익 배치 및 종모멘트 특성에 관한 실험적 연구)

  • Park, Hwa-Pyeong;Kim, Sang-Hyun;Lim, Geun-Nam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.443-450
    • /
    • 2014
  • In this study, we have discussed about the effect of hydrofoil arrangement and longitudinal moment characteristic on longitudinal motion stability of fully-submerged hydrofoil by the experiment of tandem hydrofoil model. First of all, tandem hydrofoil model that has canard wing arrangement has been made and characteristics of lift force and drag force by performing the lift force and drag force measuring experiment has also been estimated. Besides, tandem hydrofoil model's wing arrangement which has the initial stability and self stability of longitudinal motion has also been determined. In longitudinal stability experiment of tandem hydrofoil model, the motion characteristic of pitch and heave and the longitudinal stability of foil borne condition by variation of self stability of longitudinal moment and longitudinal distance are estimated. The result from the experiment and it's important conclusion can be described as below; Increase the self stability for longitudinal moment, the higher self stability for pitch motions in a constant pitch angles. By increasing the self stability for longitudinal moment, the range of fluctuation of pitch motion and heave motion for pitch angle also will change relatively small and longitudinal stability is excellent. Lastly, when the lift force of hydrofoil is remain constants, we can conclude that securing the enough self stability for longitudinal moment is essential for stable foil borne condition of tandem hydrofoil.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

THE EXPRESSION OF OSTEONECTIN AND OSTEOCALCIN IN THE EXPERIMENTAL TOOTH MOVEMENT IN RAT (백서의 실험적 치아이동시 osteonectin 및 osteocalcin의 발현)

  • Bae, Sung-Real;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.699-716
    • /
    • 1998
  • This study was designed to evaluate the expression of non-collagenous protein in periodontal tissue during the experimental movement of rat incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for osteonectin and osteocalcin. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats) and 6 experimental groups(24 rats) where 75g of force was applied from helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. And the tissues of a control group and experimental groups were studied immunohistochemically and histologically. The results were as follows : 1. Until 28 days after force application, periodontal fibers had been strectched on tension side and compressed in pressure side of all the experimental groups, and the arrangement of periodontal fibers had not been recovered yet. 2. The expression of osteonectin in control group was rare in dentin, cementum and osteocyte, and was mild in odontoblasts and matrix of alveolar bone. 3. The expression of osteocalcin in control group was negative in gingiva, osteoblasts, osteocyte and cementum, and was rare in predentin, capillaries in pulp and periodontal ligament and the matrix of alveolar bone. 4. There was no difference in the expression of osteocalcin or osteonectin in dentin, cementum, pulp, odontoblasts, between of control and of experimental groups. 5. The expression of osteonectin in intermaxillary suture got the peak in 7-day and was declined after 14-day. The expression of osteocalcin remained in a same degree since it became mild in 14-day. 6. The expression of osteonectin in pressure side of periodontal ligament of experimental group was rare, which was similar to control group. But in tension side, it was increased until 14-day aftrer which it was declined. 7. The expression of osteocalcin in periodntal ligament was rare in 12-hour to 14-day, but became severe in 28-day, which was greater in tension side than in pressure side, and in the periodontal fiber next to alveolar bone than to tooth surface. 8. The expression of osteocalcin in alveolar bone was rare until 14-day in pressure side, but became moderate in 28-day. The expression of osteonectin was increased from 7-day by time dependency, which was greater in tension side than in pressure side.

  • PDF