• Title/Summary/Keyword: Fouling

Search Result 1,000, Processing Time 0.029 seconds

Effect of Foulant Characteristics on Membrane Fouling Index (오염물질의 특성이 막오염 지수에 미치는 영향)

  • Park, Chanhyuk;Kim, Hana;Hong, Seungkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.775-780
    • /
    • 2005
  • This study was performed to investigate the effect of foulant characteristics on Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI). A linear relationship was found relating the fouling index (both SDI and MFI) on particle concentration, but fouling index values were nonlinearly (exponentially) with increasing organic concentration. When organic matter was the primary cause of fouling, the MFI was not accurately predicted due to internal fouling such as pore adsorption. The fouling index was determined mainly by particle characteristics when both particle and organic coexisted in the feed water. This observation was attributed to lessening of organic pore adsorption by particle cake layer formed on the membrane surface. Bench-scale actual fouling experiments demonstrated that permeate flux declines much faster with feed water containing particles than organic matters although fouling potential predicted by SDI values were identical, indicating that the accurate prediction of fouling potential requires the development of fouling index reflecting different foulant characteristics.

Fouling of Ion Exchange Membranes and Their Fouling Mitigation (이온교환막의 막오염 및 오염저감)

  • 문승현;이홍주
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.55-66
    • /
    • 2002
  • fouling phenomena of ion exchange membranes were reviewed for improved design and operation of electodialysis. The membrane fouling index for electrodialysis (EDMFI) was defined for the quantitative analysis of fouling potential as an analogy to the pressure-driven membrane process. fouling phenomena were compared in the electrodialysis experiments with inorganic foulant (silica sol) and organic foulants (humate and bovine serum albumin (BSA)), and their fouling potentials were analyzed using the fouling index. The comparison showed that the EDMFI could be used as a quantitative measure of the fouling tendency in electrodialysis processes. As a novel fouling mitigation method, square wave power was reported to be effective in electrodialysis with organic foulants. The square wave powers having the pulsed electric field enabled to reduce the membrane fouling significantly at an optimal frequency.

RO Chemicals 종류 및 운영

  • Martinson, Tom
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.09a
    • /
    • pp.57-85
    • /
    • 1998
  • RO System & Membrance Support Technology Membrance Fouling -Colloidal Fouling -Scale Fouling -Biological Fouling -Chemical Fouling

  • PDF

Fouling in Enhanced Tubes-Extension of Kern-Seaton Fouling Model to Repeated Ribbed Tubes (열전달 촉진관내의 화울링 해석-2차원 리브붙이관에 Kern-Seaton 화울링 모델 적용)

  • Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.289-298
    • /
    • 1992
  • Fouling is "a major unsolved" area in heat transfer research. Currently, fouling researches are performed in every directions-fundamental aspects, modeling and cumulating experimental data. In this study, an attempt was made to extend the knowledge in enhanced tube fouling. The Kern-Seaton fouling model which was originally proposed for smooth tube fouling was extended to repeated rib tubes. Key parameters-mass transfer coefficient and wall shear stress-were modeled for repeated rib tubes. Some critical points related with the enhanced tube fouling-uncertainties in the mass transfer rate, wall shear stress modeling, deformation of roughness shape during fouling-were discussed, and some quantitative evaluations were made.

  • PDF

Fouling Analyses of Heat Exchangers for PSR (주기적안전성평가를 위한 원전 열교환기 Fouling 평가)

  • Hwang, K.M.;Jin, T.E.;Han, S.G.;Kim, B.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1467-1472
    • /
    • 2003
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. This fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper focuses on fouling analyses for six heat exchangers of two primary systems in two nuclear power plants; the regenerative heat exchangers of the chemical and volume control system and the component cooling water heat exchangers of the component cooling water system. To analyze the fouling for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. Based on the results of the fouling analyses, the present thermal performances and fouling levels for the six heat exchangers were predicted.

  • PDF

Prediction of Membrane Fouling Index by Using Happel Cell Model (Happel Cell 모델을 이용한 막오염 지수 예측)

  • Park, Chanhyuk;Kim, Hana;Hong, Seungkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.632-638
    • /
    • 2005
  • Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI) is an important parameter in design of the integrated RO/NF membrane processes for drinking water treatment. In this study, the effect of particle, membrane and feed water characteristics on membrane fouling index were investigated systematically. Higher fouling index values were observed when filtering suspensions with smaller particle size and higher feed particle concentration. Larger membrane resistance due to smaller pore size resulted in an increased membrane fouling index. The variations of feed water hardness and TDS concentrations did not show any impact on fouling index, suggesting that there were no significant colloidal interactions among particles and thus the porosity of particle cake layer accumulated on the membrane surface could be assumed to be 0.36 according to random packing density. Based on the experimental observations, fundamental membrane fouling index model was developed using Happel Cell. The effect of primary model parameters including particle size ($a_p$), particle concentration ($C_o$), membrane resistance ($R_m$), were accurately assessed without any fitting parameters, and the prediction of membrane fouling index such as MFI exhibited very good agreement with the experimental results.

Investigation of Al-hydroxide Precipitate Fouling on the Nanofiltration Membrane System with Coagulation Pretreatment: Effect of Inorganic Compound, Organic Compound, and Their Combination

  • Choi, Yang-Hun;Kweon, Ji-Hyang
    • Environmental Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.149-157
    • /
    • 2011
  • Nanofiltration (NF) experiments were conducted to investigate fouling of Al-hydroxide precipitate and the influence of organic compound, inorganic compound, and their combination, i.e., multiple foulants. $CaCl_2$ and $MgSO_4$ were employed as surrogates of inorganic compounds while humic acid was used as surrogate of organic compound. The flux attained from NF experiments was fitted with the mathematical fouling model to evaluate the potential fouling mechanisms. Al-hydroxide fouling with a cake formation mechanism had little effect on the NF membrane fouling regardless of the Al concentration. The NF fouling by Al-hydroxide precipitate was deteriorated in presence of inorganic matter. The effect of Mg was more critical in increasing the fouling than Ca. This is because the Mg ions enhanced the resistances of the cake layer accumulated by the Al-hydroxide precipitate on the membrane surfaces. However, the fouling with Mg was dramatically mitigated by adding humic acid. It is interesting to observe that the removal of the conductivity was enhanced to 61.2% in presence of Mg and humic acid from 30.9% with Al-hydroxide alone. The influence of dissolved matter (i.e., colloids) was more negative than particulate matter on the NF fouling for Al-hydroxide precipitate in presence of inorganic and organic matter.

A Study on the Development of Fouling and Plugging Margin Evaluation Methods for Shell-and-Tube Heat Exchangers (다관원통형 열교환기의 파울링 및 관막음 여유 평가법)

  • Hwang, Kyeong-Mo;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.55-60
    • /
    • 2003
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits increases and thermal performance decreases. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. The heat exchangers of nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions based on the ASME OM-S/G-Part 2 as a means of heat exchanger management. It is hard to estimate the heat performance trend and to establish the future management plan. This paper describes the fouling evaluation method which can evaluate the thermal performance for heat exchangers and estimate the future fouling variations and the plugging margin evaluation method which can reflect the current fouling level developed in this study. To develop the fouling and plugging margin evaluation methods for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose of verifying the two evaluation methods, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

  • PDF

A Study on the Diagnostic Technology for Fouling Occurred in Heat Exchanger (열교환설비에서의 파울링 진단기술에 관한 연구)

  • Chung Kyung-Yul;Rhyu Keel-Soo;Lee Hoo-Rach
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.502-508
    • /
    • 2005
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried. e.g., diagnosis of fouling, reducing and eliminating the fouling. etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously. The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall. The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator. In addition to, we showed the data that have been executed in field test for reliability verification.

A Study on The Diagnostic Technology for Fouling Occurred in Heat Exchanger. (열 교환설비에서의 파울링 진단기술에 관한 연구)

  • 정경열;이후락;박정일;김상렬;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.181-186
    • /
    • 2002
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried, e.g., diagnosis of fouling, reducing and eliminating the fouling, etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator.

  • PDF