• 제목/요약/키워드: Future MS

검색결과 215건 처리시간 0.021초

Screening Analysis of 10 Adrenal Steroids by Matrix-Assisted Laser Desorption Ionization-Tandem Mass Spectrometry

  • Kim, Sun-Ju;Jung, Hyun-Jin;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.69-72
    • /
    • 2011
  • Defective synthesis of the steroid hormones by the adrenal cortex has profound effects on human development and homeostasis. Due to the time-consuming chromatography procedure combined with mass spectrometry, the matrix-assisted laser desorption ionization method coupled to the linear ion-trap tandem mass spectrometry (MALDI-LTQ-MS/MS) was developed for quantitative analysis of 10 adrenal steroids in human serum. Although MALDI-MS can be introduced for its applicability as a high-throughput screening method, it has a limitation on reproducibility within and between samples, which renders poor reproducibility for quantification. For quantitative MALDI-MS/MS analysis, the stable-isotope labeled internal standards were used and the conditions of crystallization were tested. The precision and accuracy were 3.1~35.5% and 83.8~138.5%, respectively, when a mixture of 10 mg/mL ${\alpha}$-cyano-4-hydroxycinnamic acid in 0.2% TFA of 70% acetonitrile was used as the MALDI matrix. The limit of quantification ranged from 5 to 340 ng/mL, and the linearity as a correlation coefficient was higher than 0.988 for all analytes in the calibration range. Clinical applications include quantitative analyses of patients with congenital adrenal hyperplasia. The devised MALDI-MS/MS technique could be successfully applied to diagnosis of clinical samples.

Comparative GC-MS Based In vitro Assays of 5α-Reductase Activity Using Rat Liver S9 Fraction

  • Lee, Su-Hyeon;Lee, Dong-Hyoung;Lee, Jeong-Ae;Lee, Won-Yong;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • 제3권1호
    • /
    • pp.21-24
    • /
    • 2012
  • $5{\alpha}$-Dihydrotestosterone (DHT) is the primary active metabolite of testosterone, catalyzed by $5{\alpha}$-reductase ($5{\alpha}R$) in the skin, prostate, and liver. In this study, the $5{\alpha}R$ activity in rat liver S9 fraction in the presence of a NADPH-generating system was evaluated and compared by gas chromatography-mass spectrometry (GC-MS)-based in vitro assays. Testosterone and a $5{\alpha}R$ inhibitor, finasteride, were added to the S9 fractions and incubated at $37^{\circ}C$ for 1 h. Both testosterone and DHT were quantitatively measured and compared with two different GC-MS-based steroid profiling techniques. DHT was not detected by conventional GC-MS analysis in the absence of finasteride when the concentration of testosterone in the S9 fraction was less than $0.2{\mu}M$, whereas the isotope-dilution GC-MS (GC-IDMS) system was able to evaluate the $5{\alpha}R$ activity. Because the S9 fraction contains more reactive enzymes and is easier to collect from tissues compared with a microsomal solution, the combination of the S9 fraction and GC-IDMS technique may be a promising assay for evaluating the $5{\alpha}R$ activity in large-scale clinical studies.

Change of MS Method and Comparison of SIFT-MS Method

  • CHOI, Jong-Sun;KWON, Lee-Seung;LEE, Ji-Hoon;KIM, Romertta;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권1호
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: This study examines the history of the evolution of MS analysis and intends to consider the future direction of technological development through the difference from the latest technology, SIFT-MS. Research design, data and methodology: A method of analysis will be described in detail at the below by SIFT-MS (Selected Ion Flow Mass Spectrometry), which is a technology developed by a company called SIFT Technologies. Results: The initial concept of mass spectrometry was begun in the late 1890s, and it continues to evolve even after the 21st century through the ripening stage of the 20th century. The development process of mass spectrometry by year has been described in detail in the Main text. Conclusions: Mass spectrometry, qualitative and quantitative analysis of substances plays a very important role in the research and medical fields. The development of these analytical methods is expected to continue in the future, and faster and more accurate qualitative analysis and mass spectrometry will be developed than the level currently reached. In addition, it is expected that hardware and software will be configured so that non-analysis experts can handle it easily, and it will be used as a technology that is more closely related to our lives.

Electrospray-Mass Spectrometric Analysis of Plasma Pyrophosphates Separated on a Multi-Modal Liquid Chromatographic Column

  • Lee, Su-Hyeon;Lee, Jeong-Ae;Lee, Won-Yong;Chung, Bong-Chul;Choi, Man-Ho
    • Mass Spectrometry Letters
    • /
    • 제2권4호
    • /
    • pp.92-95
    • /
    • 2011
  • Pyrophosphates are the key intermediates in the biosynthesis of isoprenoids, and their concentrations could reveal the benefits of statins in cardiovascular diseases. Quantitative analysis of five pyrophosphates, including isopentenyl pyrophosphate (IPP), dimethylallyl pyrophosphate (DMAPP), geranyl pyrophosphate (GPP), farnesyl pyrophosphate (FPP), and geranylgeranyl pyrophosphate (GGPP), was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in negative ionization mode. After dilution with methanol, samples were separated on a 3 ${\mu}m$ particle multi-modal $C_{18}$ column ($50{\times}2$ mm) and quantified within 10 min. The gradient elution consists of 10 mM ammonium bicarbonate and 0.5% triethylamine (TEA) in water and 0.1% TEA in 80% acetonitrile was used at the flow rate of 0.4 mL/min. Overall recoveries were 51.4-106.6%, while the limit of quantification was 0.05 ${\mu}g$/mL for GPP and FPP and 0.1 ${\mu}g$/mL for IPP, DMAPP, and GGPP. The precision (% CV) and accuracy (% bias) of the assay were 1.9-12.3% and 89.6-111.8%, respectively, in 0.05-10 ${\mu}g$/mL calibration ranges ($R^2$ > 0.993). The devised LC-MS/MS technique with the multi-modal $C_{18}$ column can be used to estimate the biological activity of pyrophosphates in plasma and may be applicable to cardiovascular events with cholesterol metabolism as well as the drug efficacy of statins.

고등어(Scomber japonicus) 치어의 마취제로서 Clove oil, MS-222 및 2-Phenoxyethanol의 평가 (Comparative Efficacy of Clove oil, MS-222 and 2-Phenoxyethanol as Anesthetics in Juvenile Scomber japonicus)

  • 한석중;김경민;최낙중;구준호;박충국;이원교;지승철
    • 한국수산과학회지
    • /
    • 제44권6호
    • /
    • pp.653-657
    • /
    • 2011
  • The efficiency of clove oil, MS-222, and 2-phenoxyethanol was evaluated as anesthetics in juvenile Scomber japonicus. Stage A5 of anesthesia was assumed to be sufficient for conducting routine aquaculture procedures in less than 3 min, with recovery (stage R5) in less than 5 min. The lowest effective doses of the three anesthetics were 50 mg $L^{-1}$ clove oil (anesthetic time of 71.3 s and recovery time of 167.0 s), 100 mg $L^{-1}$ MS-222 (anesthetic time of 70.7 s and recovery time of 115.7 s), and 400 mg $L^{-1}$ 2-phenoxyethanol (anesthetic time of 86.7 s and recovery time of 95.0 s). Anesthetic times decreased with increasing doses for all three anesthetic agents, and fish anesthetized with clove oil exhibited the longest recovery times. After 30 min, the highest plasma cortisol and lactate levels were detected with the use of clove oil, whereas the lowest values were observed with 2-phenoxyethanol. In addition, high glucose levels were maintained during recovery with clove oil, but the treatments did not significantly differ. The most effective of the three anesthetic agents was 2-phenoxyethanol, although all were considered acceptable for use in cultures of juvenile Scomber japonicus.

Analytical Techniques Using ICP-MS for Clinical and Biological Analysis

  • Ko, Jungaa;Lim, H. B.
    • Mass Spectrometry Letters
    • /
    • 제6권4호
    • /
    • pp.85-90
    • /
    • 2015
  • This article reviews recent analytical techniques using inductively coupled plasma-mass spectrometry (ICP-MS) immunoassay for clinical and bio analysis. We classified the techniques into two categories, direct and indirect analysis, which depend upon a guideline of whether tagging materials are used or not. Direct analysis is well known, and generally used in conjunction with various other techniques, such as laser ablation, chromatographic separations, etc. Recently, indirect analysis using tagging elements has intensively been discussed because of its importance in future applications to bio and clinical analysis, including environmental and food industries. The method has shown advantages of multiplex detection, excellent sensitivity, and short analysis time owing to signal amplification and magnetic separation. Now, it expands the application field from small biomolecules to large cells.

단백체 분석을 위한 일차원 및 이차원 역상크로마토그래피의 비교 (Comparison of 2-D RP-RP MS/MS with 1-D RP MS/MS for Proteomic Analysis)

  • 문평곤;조영은;백문창
    • 약학회지
    • /
    • 제54권5호
    • /
    • pp.377-386
    • /
    • 2010
  • Single-dimensional (1-D) and two-dimensional (2-D) LC methods were utilized to separate peptides from various sources followed by MS/MS analysis. Two-dimensional ultra-high performance liquid chromatography is a useful tool for proteome analysis, providing a greater peak capacity than 1-D LC. The most popular 2-D LC approach used today for proteomic research combines strong cation exchange and reversed-phase LC. We have evaluated an alternative mode for 2-D LC of peptides using 2-D RP-RP nano UPLC Q-TOF Mass Spectrometry, employing reversed-phase columns in both separation dimensions. As control experiments, we identified 129 proteins in 1-D LC and 322 proteins in 2-D LC from E. coli extract peptides. Furthermore, we applied this method to rat primary hepatocyte and a total of 170 proteins were identified from 1-D LC, and 527 proteins were identified from all 2-D LC system. The in-depth protein profiling established by this 2-D LC MS/MS from rat primary hepatocyte could be a very useful reference for future applications in regards to drug induced liver toxicity.

한국의 경영과학 : 회고와 전망 (OR/MS in Korea : The Review and Outlook)

  • 김여근;김재윤
    • 대한산업공학회지
    • /
    • 제40권6호
    • /
    • pp.592-608
    • /
    • 2014
  • This paper reviews Operations Research (OR)/Management Science (MS) in Korea. After a brief survey of global OR/MS, this paper analyzes the research trend in Korea over the past forty years with respect to approach, methods, types of data, and so on. The OR/MS application and practice in Korea are also surveyed and the change of them with time is shown. To do this, we refer to four main OR/MS journals published in Korea. The future of OR/MS is discussed in practice, methods to problem-solving, and education.

Applications of MALDI-TOF Mass Spectrometry in Clinical Microbiology

  • Shin, Kyeong Seob;Yum, Jonghwa
    • 대한의생명과학회지
    • /
    • 제28권3호
    • /
    • pp.145-156
    • /
    • 2022
  • Over the past few decades, few technologies have had a greater impact on clinical microbiology laboratories than matrix-assisted laser desorption time-of-flight mass spectrometry (MALDI-TOF MS). The MALDI-TOF MS is a fast, accurate, and low-cost and efficient method of microbial identification. This technology generates characteristic mass spectral fingerprints that is a unique signature for each microorganism, making it an ideal method for accurate identification at the genus and species levels of both bacterial and fastidious microorganism such as anaerobes, mycobacterium and fungi etc. In addition, MALDI-TOF MS has been successfully used in microbial subtyping and susceptibility tests such as determination of resistance genes. In this study, the authors summarized the application of MALDI-TOF MS in clinical microbiology and clinical research and explored the future of MALDI-TOF MS.

Mobility Support Architecture in Locator-ID Separation based Future Internet using Proxy Mobile IPv6

  • 석승준
    • 한국지능시스템학회논문지
    • /
    • 제24권2호
    • /
    • pp.209-217
    • /
    • 2014
  • Of several approaches for future Internet, separating two properties of IP address into locator and identifier, is being considered as a highly likely solution. IETF's LISP (Locator ID Separation Protocol) is proposed for this architecture. In particular, the LISP model easily allows for device mobility through simple update of information at MS (Mapping Server) without a separate protocol. In recent years, some of the models supporting device mobility using such LISP attributes have emerged; however, most of them have the limitation for seamless mobility support due to the frequent MS information updates and the time required for the updates. In this paper, PMIPv6 (Proxy Mobile IPv6) model is applied for mobility support in LISP model. PMIPv6 is a method that can support mobility based on network without the help of device; thus, this we define anew the behavior of functional modules (LMA, MAG and MS) to fit this model to the LISP environment and present specifically procedures of device registration, data transfer, route optimization and handover. In addition, our approach improves the communication performance using three tunnels identified with locators between mobile node and corresponding node and using a route optimized tunnel between MN's MAG and CN's MAG. Finally, it allows for seamless mobility by designing a sophisticated handover procedure.