• 제목/요약/키워드: Gas blast

검색결과 176건 처리시간 0.03초

고로내 열유동 현상의 수치해석 사례(I) (Numerical simulation of thermo-fluid flow in the blast furnace)

  • 진홍종;최상민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2038-2043
    • /
    • 2007
  • Analysis of the internal state of the blast furnace is needed to predict and control the operating condition. Especially, it is important to develop modeling of blast furnace for predicting cohesive zone because shape of cohesive zone influences on overall operating condition of blast furnace such as gas flow, temperature distribution and chemical reactions. Because many previous blast furnace models assumed cohesive zone to be fixed, they can't evaluate change of cohesive zone shape by operation condition such as PCR, blast condition and production rate. In this study, an axi-symmetric 2-dimensional steady state model is proposed to simulate blast furnace process using the general purpose-simulation code. And Porous media is assumed for the gas flow and the potential flow for the solid flow. Velocity, pressure and temperature distribution for gas and solid are displayed as the simulation results. The cohesive zones are figured in 3 different operating conditions.

  • PDF

Blasting wave pattern recognition based on Hilbert-Huang transform

  • Li, Xuelong;Wang, Enyuan;Li, Zhonghui;Bie, Xiaofei;Chen, Liang;Feng, Junjun;Li, Nan
    • Geomechanics and Engineering
    • /
    • 제11권5호
    • /
    • pp.607-624
    • /
    • 2016
  • Rockburst is becoming more serious in Chinese coal mine. One of the effective methods to control rockburst is blasting. In the paper, we monitored and analyzed the blasting waves at different blast center distances by the Hilbert-Huang transform (HHT) in a coal mine. Results show that with the increase of blast center distance, the main frequency and amplitude of blasting waves show the decreasing trend. The attenuation of blasting waves is slower in the near blast field (10-75 m), compared with the far blast field (75-230 m). Besides, the frequency superposition phenomenon aggravates in the far field. A majority of the blasting waves energy at different blast center distances is concentrated around the IMF components 1-3. The instantaneous energy peak shows attenuation trend with the blast center distance increase, there are two obvious energy peaks in the near blast field (10-75 m), the energy spectrum appears "fat", and the total energy is greater. By contrast, there is only an energy peak in the far blast field, the energy spectrum is "thin", and the total energy is lesser. The HHT three dimensional spectrum shows that the wave energy accumulates in the time and frequency with the increasing of blast center distance.

촉진제 첨가에 따른 철강공정 배기가스 하이드레이트 상평형 영향 (Thermodynamic promoter effects on the phase equilibrium of BFG(Blast Furnace Gas) hydrate)

  • 이보람;사정훈;박다혜;곽계훈;이건홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.125.1-125.1
    • /
    • 2011
  • $CO_2$ separation from a flue gas by using the gas hydrate technology was suggested by Kang et al. They reported phase equilibrium conditions of mixed gases composed of $CO_2$ and N2 with THF as a thermodynamic promoter. In this study, we reported the phase equilibrium conditions of a mixed gas which had a realistic composition of the blast furnace gas (BFG) emitted from the steel-making process. The phase equilibrium measurements were done by using the "continuous" QCM method, and the results demonstrate that this method is efficient and as accurate as the conventional temperature search method.

  • PDF

복합소호형 가스 차단기의 SLF 차단 성능 해석 (Analysis of SLF Interruption Performance in self-blast Gas Circuit Breaker)

  • 박진근;안희섭;최종웅;김영근;조해용
    • 한국기계가공학회지
    • /
    • 제19권9호
    • /
    • pp.24-32
    • /
    • 2020
  • A self-blast type gas circuit breaker has been studied in this study to improve efficiency of interrupting performance of short line fault(SLF). Hot gas flows of gas circuit breaker have been simulated to evaluate interruption performance using CFD. Design parameters such as various types of expansion chamber and nozzles are suggested by using simulation results. Simulated results and experimental ones are compared with previous (ones that of in under development and with capacitor) GCB. Modified new shape of an expansion chamber and nozzle has been suggested to improve the efficiency of gas flow and to provide guidelines for designing self-blast breaker with a higher interruption capability.

발파진동 제어에 의한 특수구간 터널굴착에 관한 연구 (A Study on Tunnel Excavation by Controlled Blast Vibration at Particular Environment Conditions)

  • 최형빈;임한욱
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.257-267
    • /
    • 2000
  • It was difficult to apply conventional excavation methods in some sections from Seoul to Pusan high speed rail road construction of 1 lot 2, due to highway concrete road, gas pipe, water pipe and nearby factories with automatic control system machine. To excavate safely and efficiently in these sections new blast patterns were employed within allowable blast vibration level, by test blast and controlled vibration by sequential blast. Behaviors of the rock mass including convergence and displacement around tunnel were measured with construction works and the crack width in concrete wall was also monitored for controlling allowable limits. The results can be summarized as follow : 1. The allowable blast vibration level in structure site is less 1.0cm/sec for highway concrete, 0.5 cm/sec for gas pipe, water pipe and building housing and 0.3 cm/sec for automatic control system machine. 2. The convergence displacement, single rod extensometer and multi rod extensometer around tunnel and cracks in concrete wall were measured, it was confirmed that the measured values were converged within allowable level. 3. The empirical formular of ground vibrations with 90% confidence lines for PD-3 was given as follow. $$V_{90%}=45.549({\frac{D}{\sqrt{W}}})^{-1.353}$$

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

건설진동에 의한 가스배관의 진동예측 프로그램 개발 (Development of Vibration Prediction Program of Gas Pipeline by Construction Vibration)

  • 정석영;홍성경;김준호;고재필
    • 한국가스학회지
    • /
    • 제5권2호
    • /
    • pp.30-35
    • /
    • 2001
  • 현재 운용중인 가스배관은 다양한 건설진동에 의하여 영향을 받고 있다. 특히 지하철 공사 및 도로공사 시에는 건설장비의 사용, 대형차량의 통행 및 발파 등으로 인해 발생되는 건설진동이 가스관에 큰 영향을 미친다. 매설가스관의 경우는 매설된 위치와 근접한 곳에서 시행되는 발파로 인한 진동영향이 큰 상태이며 노출가스관의 경우는 차량진동에 대하여 가장 크게 영향을 받고 있다. 본 논문에서는 가스배관 주변에서 발생하는 건설진동을 측정, 분석함으로써 건설진동에 의한 가스배관의 진동을 손쉽게 예측할 수 있는 가스관 진동예측 프로그램을 소개하였다. 이 프로그램은 가스관의 진동을 예측하는 소프트웨어로 기존의 신뢰성 분석된 경험식과 유한요소해석을 통한 구조해석 결과를 이용하여 매설 및 노출 가스관에서의 진동치를 현장조건에 따라 예측할 수 있고, 측정된 진동데이터를 데이터베이스화 할 수 있는 기능을 가지고 있다. 또한 현장에서 발파진동을 측정하여 발파진동추정식을 산정하고, 지발당 허용장약량을 나타내는 그래프를 자동으로 형성할 수 있는 기능을 가지고 있다. 따라서 현장 근무자가 손쉽게 가스관 주변에서 진동을 예측하여 가스관의 안전성을 평가할 수 있다.

  • PDF

고로하부 액체유동에 대한 수치해석 사례 - 냉간유동 (Numerical Simulation of the Liquid Flow in the Lower Part of the Blast Furnace - A Cold Flow Case)

  • 진홍종;최상민;정진경
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.33-41
    • /
    • 2008
  • The high permeability of the gas in the molten iron of the dripping zone of the blast furnace is a major factor in achieving the stable operation of a furnace with high productivity. Basic studies of the liquid flow behavior in a packed bed are necessary to grasp the effect of various operational changes on conditions in the dropping zone. Molten iron and slag together playa critical role in the lower zone, transporting mass and energy, while impairing and redistributing the gas flow. In turn, molten iron and slag undergo physical and chemical changes, and are redistributed radially as they descend to the hearth. In this research, mathematical formulations are derived for the gas and the liquid. The solid phase is fixed with constant porosity. The information for the molten iron and slag includes the hold-up, velocity, pressure, and information related to the areas of interaction between the gas and the liquid, and the solid and the liquid. Predictable results include the velocity, pressure and temperature distribution. Additional parameters include the packed particle size and the air blast rate.

  • PDF

철강공정 배기가스로부터 가스 하이드레이트 형성에 미치는 촉진제의 영향 (Effects of Promoter on the Formation of Gas Hydrate from Blast Furnace Gas)

  • 곽계훈;사정훈;김시환;이보람;이건홍
    • Korean Chemical Engineering Research
    • /
    • 제53권1호
    • /
    • pp.103-110
    • /
    • 2015
  • 본 연구에서는 가스 하이드레이트 기술을 이용하여 철강 공정 배기가스로부터 $CO_2$를 분리하는데 사용하는 여러 촉진제의 성능을 조사하였다. 이 실험에서는 $CO_2/N_2$ 혼합가스 ($CO_2/N_2$=20/80, 40/60)와 $CO_2/N_2$ 이외에 CO, $H_2$가 첨가된 Blast furnace gas (BFG) 모델 가스를 대상 가스로 사용하였다. 촉진제로는 구조 II 하이드레이트를 형성한다고 알려진 tetrahydrofuran (THF), propylene oxide, 1,4-dioxane 를 사용하였으며, 각 가스에 대하여 촉진제를 농도별로 첨가했을 때 상평형점의 변화를 측정하였다. 상평형점은 "연속" Quartz crystal microbalance (QCM) 방식을 이용하였다. 또한, Powder X-ray diffraction (PXRD) 분석을 통하여 촉진제의 첨가가 가스 하이드레이트 구조에 미치는 영향을 알아보았다.

분리형 히트파이프의 저발열량 연료가스 예열시스템에 대한 적용연구 (Application of a Large Scale Heat Pipe System to Preheating the Fuel Gas of Low Heating Value)

  • 박흥수;유갑종;이진호;이용국
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1085-1097
    • /
    • 1999
  • A separate heat pipe system capacity of 3,700kW has been developed and applied to preheating the blast furnace gas for recovery of the waste heat from boiler. The system is designed to preheat the blast furnace gas up to $126^{\circ}C$ by using tho boiler exhaust gas of which temperature is $180^{\circ}C{\sim}220^{\circ}C$. The arrangement of the fin tubes as well as the shape of the fin has been carefully determined to minimize the fouling problems. The heat pipe system was found to be stable in circulation of the working fluid and the range of the temperature variation of the preheated blast furnace gas was within $10^{\circ}C$. It was proved through a long-term test that the selected tube arrangement and the shape of the fins are proper to prevent the fouling problems and that the pay-back period of the system Is within one year.