• Title/Summary/Keyword: Glazings

Search Result 7, Processing Time 0.024 seconds

A Study on Thermal & Electrical Performance of Glazings with DSC modules (염료감응태양전지(DSC)를 적용한 Glazing의 구성에 따른 단열 및 전기 성능 분석)

  • kim, Ji-Seong;Park, Se-Hyeon;Kang, Jun-Gu;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.158-163
    • /
    • 2011
  • Recently, more attention has been paid to DSC(Dye-sensitized Solar Cell) with the potential of glazing applications. The aim of the study is to analyze thermal and electrical performance according to composition of glazing with DSC. For this study, the electrical and thermal performance of glazing with DSC modules were measured and their result were compared. The measurement were performed according to the KS L2525 and with a solar simulator of DSC modules. The result show that the U-value of the DSC double glazings with clear glass and low-e glass were 2.78 $W/m^2K$ and 1.70 $W/m^2K$, respectively. The electrical measurement indicated that the electrical efficiency of the DSC double glazings with clear glass and low-e glass decreaced by 9.9% and 13.3%, respectively, compared to the DSC medules electrical performance.

  • PDF

Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind (베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구)

  • Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

A Study on the Air System for Space Heating (공기식 집열시스템에 의한 실내 난방 연구)

  • Chun, Won-Gee;Lim, Sang-Hoon;Jeon, Myung-Seok;Yoon, Jong-Ho
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.34-39
    • /
    • 1992
  • The present study has carried out thermal performance evaluation of air systems for space heating in Daejeon by the f-chart method. The various effects with the change in air flow rate, number of glazings, storage capacity of pebble bed, and coating materials of absorber plate are analyzed with regard to the effectiveness of air systems for space heating. A comparison is also made with liquid systems under the same operating conditions.

  • PDF

Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201 (NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가)

  • Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

A study of Illumination on Exhibitory Space by Natural Light Through the Inducing Space (자연채광 유도공간에의한 전시공간내 채광에 관한 연구)

  • Hwang, Kyu-Seon;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.48-55
    • /
    • 2012
  • In recent years, it clearly shows the tendency toward the utilization of daylight in many exhibitory buildings such as museum since the expectation of visitors for whom high illuminance levels are preferable to perceive the details of the works of art. Shading devices and special glazings are often used as the tool to control the amount of light and heat which should be avoided for the presentation of high-light sensitive art works such as paintings. Another way of controling the light is to provide the space for inducing and attenuating light in the exhibitory building. This study aims to investigate the illuminance on the exhibitory space when the space for inducing and attenuating light is applied. Interaction between the daylight and the space was simulated by Lumen Micro program with variation of the size of the exhibitory space, the length of inner wall, surface reflectivity, area of windows to obtain the illumination of the wall surface. This study shows that those variables affect the illumination on the wall surfaces. By comparing the results with suggestive illumination of KS and ICOM, available wall for display on natural lighting are suggested for the seasons and time.

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

A Design and Performance Evaluation of Differentiated Daylight-Glazing Systems (가변 투과시스템의 광제어 특성을 고려한 통합 채광시스템의 적용성 평가에 관한 연구)

  • Kim, Gon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.13-22
    • /
    • 2005
  • This research aimed to generate two points of daylighting application as follows: 1) providing daylight performance data with a variety of glazing materials for a large window and 2) designing and evaluating an experimental type of differentiated window. For this purpose, we compared the daylight and distribution performance of new defined type of window configuration to the conventional window counterpart with a variety of glazing materials. The comparison was made for a deep, south-facing perimeter zone with large window, without any interior obstruction. The conventional window is the base single homogeneous glass pane, where as the differentiated window uses of two different glazings; an upper daylight glazing with high visible transmission and lower view window with lower transmittal glass. The daylight performance data was translated into a ratio between outdoor illuminance and the interiors. The simulated analysis of the conventional window indicates that the interior light levels have been changed proportionally dependent on the transmittance of the applied glass. The comparison of daylight distribution analysis showed that the differentiated window has lots of photometric advantage by the optical function of upper daylight window. In particular, the contribution of higher daylight window into deep rear space must be stressed for daylighting application.