• Title/Summary/Keyword: Gradient Echo

Search Result 175, Processing Time 0.026 seconds

A Study on Dynamic Susceptibility-weighted Perfusion MR Imaging at High Magnetic Filed : Comparison of Gradient Echo-EPI and Spin Echo-EPI (고 자장에서 Dynamic Susceptibility Contrast 효과에 관한 연구 : Gradient EPI와 Spin-EPI기법의 비교)

  • Goo, Eun-Hoe;Chae, Hong-In;Park, Jong-Bae;Im, Cheong-Hwan;Kim, Jeong-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.11-16
    • /
    • 2007
  • We have evaluated and compared of gradient echo and spin echo EPI for compensating about deeply distortion aspect in case of post-operation patients in magnetic resonance image. A total of 100 patients were performed on 3.0 T(GE Signa Excite E2, USA) with 8ch head coil. As a result of analysis, The SNRs of whiter and gray matter areas were 36.74 $\pm$ 06 and 39.96 $\pm$ 09 in the gradient echo EPI, the SNRs which white and gray matter areas were slightly higher than gradient echo EPI(P<0.005, paired student t-test). It was 46.24 $\pm$ 11 and 51.38 $\pm$ 13 in gradient and spin echo EPI, respectively. The signal intensity in the whiter and gray matter areas also were 87.33 $\pm$ 15.24 and 140.66 $\pm$ 13.45 in the gradient echo EPI techniques, The signal intensity of gradient echo EPI showed higher values compared to spin echo EPI. Otherwise, gradient echo EPI technique is distortion enough to operation wound and edge of the image, while spin echo EPI technique did not appear almost. In this point, the spin echo EPI technique, after surgical operation according to patient state beside gradient echo EPI techniques that signalbeside gradient echo EPI techniques that signal intensity is high and patient's case which image distortion is serious by metal etc, will be provide the useful information in adults and pediatric patients.

  • PDF

Gradient Optimized Gradient-Echo Gradient Moment Nulling Sequences for Flow Compensation of Brain Images

  • Jahng, Geon-Ho;Stephen Pickup
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.20-26
    • /
    • 2000
  • Gradient moment nulling techniques require the introduction of an additional gradient on each axis for each order of motion correction to be applied. The additional gradients introduce new constraints on the sequence design and increase the demands on the gradient system. The purpose of this paper is to demonstrate techniques for optimization of gradient echo gradient moment nulling sequences within the constraints of the gradient hardware. Flow compensated pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. The design of the gradient moment nulling sequences requires the solution of a linear system of equations. A Mathematica package was developed that interactively solves the gradient moment nulling problem. The package allows the physicist to specify the desired order of motion compensation and the duration of the gradients in the sequence with different gradient envelopes. The gradient echo sequences with first, second, and third order motion compensation were implemented with minimum echo time. The sequences were optimized to take full advantage of the capabilities of the gradient hardware. The sequences were used to generate images of phantoms and human brains. The optimized sequences were found to have better motion compensation than comparable standard sequences.

  • PDF

A Unified Gradient Shape on the Slice-Selection Axis for Flow Compensation (스핀에코 펄스 시퀀스의 슬라이스 선택방향에서 혈류 보상을 위한 통일 경사자장법 연구)

  • Pickup, Stephen;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.70-80
    • /
    • 2006
  • Spin echo gradient moment nulling pulse sequences were designed and implemented on a clinical magnetic resonance imaging system. A new technique was introduced for flow compensation that minimized echo time and effectively suppresses unwanted echoes on the slice selection gradient axis in spin echo sequences. A unified gradient shape was used in all orders of flow compensation up to the third order. A dual-purpose gradient was applied for flow compensation and to reduce unwanted artifacts. The sequences were used to generate images of phantoms and/or human brains. This technique was especially good at reducing eddy currents and artifacts related to imperfection of the refocusing pulse. The developed sequences were found to have shorter echo times and better flow compensation in through-plane flow than those of the previous models that were used by other investigators.

  • PDF

Flow Effects on Tailored RF Gradient Echo (TRFGE) Magnetic Resonance Imaging : In-flow and In-Plane Flow Effect (Tailored RF 경자사계방향 (TRFGE} 자기공명영상(MRI)에서 유체에 의한 영상신호 변화 : 유체유입효과와 영상면내를 흐르는 유체의 효과에 대하여)

  • Mun, Chi-Ung;Kim, Sang-Tae;No, Yong-Man;Im, Tae-Hwan;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.243-251
    • /
    • 1997
  • In this paper, we have reported two interesting flow effects arising in the TRFGE sequence using water flow phantom. First, we have shown that the TRFGE sequence is indeed not affected by "in-flow" effect from the unsaturated spins flowing into the imaging slice. Second, the enhancement of "in-plane flow" signal in the readout gradient direction was observed when the TRFGE sequence was used without flow compensation. These two results have many interesting applications in MR imaging other than fMRI. Results obtained were also compared with the results obtained by the conventional gradient echo(CGE) imaging. Experiments were performed at 4.7T MRI/S animal system (Biospec, BRUKER, Switzerland). A cylindrical phantom was made using acryl and a vinyl tube was inserted at the center(Fig. 1). The whole cylinder was filled with water doped with $MnCl_2$ and the center tube was filled with saline which flows in parallel to the main magnetic field along the tube. Tailored RF pulse was designed to have quadratic ($z^2$) phase distribution in slice direction(z). Imaging parameters were TR/TE = 55~85/10msec, flip angle = $30^{\circ}$, slice thickness = 2mm, matrix size = 256${\times}$256, and FOV= 10cm. In-flow effect : Axial images were obtained with and without flow using the CGE and TRFGE sequences, respectively. The flow direction was perpendicular to the image slice. In-plane flow : Sagittal images were obtained with and without flow using the TRGE sequence. The readout gradient was applied in parallel to the flow direction. We have observed that the "in-flow" effect did not affect the TRFGE image, while "in-plane flow" running along the readout gradient direction enhanced the signal in the TRFGE sequence when flow compensation gradient scheme was not used.

  • PDF

Self-Diffusion Coefficients of Colloidal Association Structures in ADS/OTAC Mixed Aqueous Solutions by Pulsed (Field) Gradient Spin Echo-NMR (Pulsed (Field) Gradient Spin Echo (PGSE) NMR에 의한 ADS/OTAC 혼합 수용액에서의 콜로이드 회합체의 자가 확산 계수)

  • Kim, Hong-Un;Lim, Kyung-Hee;Kim, Eun-Hee;Cheong, Chae-Joon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.339-348
    • /
    • 2002
  • Self-diffusion coefficients of colloidal ass9Ciation structures in the aqueous solutions of anionic ammonium dodecyl sulfate (ADS) and cationic octadecyltrimethylammonium chloride (OTAC) surfactants were measured by pulsed-gradient spin echo NMR. The results were interpreted on the basis of the ADS/OTAC/water phase diagram. Crossing the phase boundaries, significant changes in self diffusion coefficients were observed and well correlated to the phase diagram. For the micelles their apparent radii were obtained from Stokes-Einstein equation. Their values were 15 for the ADS micelles and 54 ${{\AA}}$ for the OTAC micelles, respectively. For vesicles which were formed spontaneously at different relative amounts of the surfactants and total surfactant concentrations, the radius was measured as 50 to 200 nm. This result is in fair agreement with those by TEM and light scattering.

Reduction of Susceptibility Artifact in MR Gradient Echo Imaging (MR Gradient Echo 영상술에서 자화율에 의한 에러의 감소에 관한 연구)

  • Ro, Y.M.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.19-23
    • /
    • 1990
  • A new technique for reducing the susceptibility artifact in gradient echo imaging which uses a tailored RF pulse is proposed. It is applied to the case of imaging where artifacts and distortions arise due to the high local magnetic field inhomogeneity i. e., the susceptibility. The signal loss and void phenomena due to susceptibility in a voxel are studied and a correction method using a tailored RF pulse is proposed. Applications of this method in imaging are given and experimental results obtained using an human volunteer with a 2.0 T KAIS NMR system are presented.

  • PDF

Measurement and Compensation of Respiration-Induced B0 Variations in Lumbar Spine Bone Marrow Fat Quantification

  • Nam, Yoonho;Hwang, Eojin;Jung, Joon-Yong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • Purpose: To investigate and compensate the effects of respiration-induced B0 variations on fat quantification of the bone marrow in the lumbar spine. Materials and Methods: Multi-echo gradient echo images with navigator echoes were obtained from eight healthy volunteers at 3T clinical scanner. Using navigator echo data, respiration-induced B0 variations were measured and compensated. Fat fraction maps were estimated using $T2^*$-IDEAL algorithm from the uncompensated and compensated images. For manually drawn bone marrow regions, the estimated B0 variations and the calculated fat fractions (before and after compensations) were analyzed. Results: An increase of temporal B0 variations from inferior level to superior levels was observed for all subjects. After compensation using navigator echo data, the effects of the B0 variations were reduced in gradient echo images. The calculated fat fractions show significant differences (P < 0.05) in L1 and L3 between the uncompensated and the compensated. Conclusion: The results of this study raise the need for considering respiration-induced B0 variations for accurate fat quantification using gradient echo images in the lumbar spine. The use of navigator echo data can be an effective way for the reduction of the effects of respiratory motion on the quantification.

Functional MR Imaging of Cerebral Motor Cortex on 3 Tesla MR Imaging : Comparison between Gradient and Spin-Echo EPI Techniques (3T에서 뇌 운동피질의 기능적 자기공명영상 연구 : Gradient-Echo와 Spin-Echo EPI의 비교)

  • Goo, Eeu-Hoe;Chang, Hye-Won;Chung, Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.31-38
    • /
    • 2007
  • To evaluate the accuracy and extent in the localization of cerebral motor coutex activation using a gradient- echo echo planar imaging(GE-EPI) compared to spin-echo echo planar iimaging(SE-EPI) on 3T MR imaging. Functional MR imaging of cerebral motor cortex activation was examined in GE-EPI and SE-EPI in five healthy male volunteers. A right finger movement was accomplished with a paradigm of 6 task and rest, periods and the cross-correlation was used for a statistical mapping algorithm. We evaluated any sorts of differenced of the time seried and the signal intensity changes between the rest and task periods obtained with two technoques. The qualitative analysis was distributed with activation sites of large veins and small veins by using two techniques and was found that both the techniques were clinically uesful for delineating large veins and small veins in fMRL Signal intensity charge of the rest and activation periods provided simmilar activations in both methods(GE-EPI : 0.93$\pm$0.11, SE-EPI : 0.80$\pm$.015) but the signal intensity in GE-EPI(133.95$\pm$15.76) was larger than in SE-EPI(74.5$\pm$18.90). The average SNRs of EPI raw data were higher at SMA in SE-EPI(48.54$\pm$12.37) than GE-EPI(41.4$\pm$12.54) and at M1 in SE-EPI(43.24$\pm$11.77) than GE-EPI(38.27$\pm$6.53). The localization of activation voxels of the GE-EPI showed a larger vein but the SE-EPI generally showed small vein. Then the analysis results of the two techniques were used for a statistacal paired student t-test. SE-EPI was found clinically useful for localizing the cerebral moter cortex cativation on 3.0T, but showed a little different activation patterns comparad to GE-EPI. In conclusion, SE-EPI may be feasible and can detect true cortical activation from capillaries and GE-EPI can obtain the large veins in the motor cortex activation on 3T MR imaging.

  • PDF