• Title/Summary/Keyword: Gravimetric method

Search Result 209, Processing Time 0.023 seconds

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

A Study on the Measurement Uncertainty of Flowmeter Calibrator (유량계 교정장치의 측정불확도에 관한 연구)

  • Im, Gi-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

The Gravimetric Determination of Scandium by di-(2-ethylhexyl)phosphate

  • Cha Ki-Won;Jeong Eul-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.9-12
    • /
    • 1994
  • The gravimetric determination of scandium by di-(2-ethylhexyl)phosphate(DEHPA) as a precipitant and the mole ratio of Sc-DEHPA arecipitation obtained in ethanol medium have been investigated. Scandium can be determined by gravimetric method of precipitation of Sc-DEHPA and the mole ratio of Sc-DEHPA is found as 1 :2 in ethanol medium.

Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions (측정방법 및 기상상태에 따른 PM-10 질량농도 비교)

  • Jung, Chang Hoon;Park, Jin Hee;Hwang, S.M.;Jung, Y.G.
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.53-62
    • /
    • 2009
  • In this study, the continuous monitoring of the concentration of PM-10 atmospheric particulate matter using beta ray attenuation method was compared with gravimetric method from September, 2006 to August, 2007. On the effects of the PM-10 concentration and mass difference by relative humidity and precipitation were considered. The result showed that the measurement error between beta ray method and gravimetric method are within -3~6% in average, which means PM-10 concentration data with beta ray method are relatively comparable. The current study also shows that the high PM-10 concentration events are mainly due to haze, Asian dust, and high relative humidity and the PM-10 mass concentration is closely related with relative humidity and precipitation events. Based on daily mean data, the PM-10 increases as relative humidity increases up to 70~80%, then decreases over 80% due to the precipitation. However, the distinct measurement discrepancy was not shown between beta ray method and gravimetric method based on current results. Consequently, this study shows that the collocated measurement in different instrument is essential in order to quantify the accuracy of PM-10. Furthermore, the more comprehensive and spatially distributed comparison is needed and this is remained for future study.

  • PDF

Proteolysis of Defatted Rice Bran Using Commercial Proteases and Characterization of Its Hydrolysates (탈지미강 단백질의 가수분해 및 분해물의 특성 연구)

  • Kim, Chang-Won;Kim, Hyun-Seok;Kim, Byung-Yong;Baik, Moo-Yeol
    • Food Engineering Progress
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • The defatted rice bran (DRB) was enzymatically hydrolyzed using eight commercial proteases for 4hr at optimum pH and temperature. Proteolytic hydrolysates were examined in supernatant and precipitate using lowry, semimicro kjeldahl and gravimetric method using weight difference before and after enzymatic hydrolysis. In lowry and kjeldahl protein assay method, two proteases (Alcalase and Protease N) were found to be the most effective enzymes. In gravimetric method, 60.6~118.3 mg protein/g DRB was hydrolyzed after eight commercial proteases treatments. Similar to lowry and kjeldahl method, 118.3 and 107.1 mg protein/g DRB were hydrolyzed after Alcalase and Protease N treatments, respectively. When two or three effective proteases (Protamex, Alcalase and Protease N) were applied at one time to obtain synergistic effect, significant increase (P<0.05) was observed when three proteases were applied at one time (63.4 mg protein/g DRB in lowry method and 204.5 mg protein/g DRB in gravimetric method). This result suggests that Alcalase and Protease N were the most effective enzymes for proteolysis of DRB and three commercial enzymes (Protamex, Alcalase and Protease N) showed the synergistic effect on the hydrolysis of DRB.

Resistant Starch Yield from Autoclaved Maize Starches with Different Enzymatic Assay (분리방법에 따른 효소저항전분의 수율 비교)

  • Lee, Shin-Kyung;Mun, Sae-Hun;Shin, Mal-Shick
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.383-386
    • /
    • 1997
  • Maize starches with different amylose content were repeated autoclaving-cooling cycles up to 4 times, and the yield of resistant starch (RS) from autoclaved maize starches was investigated by enzymatic-gravimetric method and ${\alpha}-amylase$ treatment. With increasing amylose content in starch and the number of autoclaving-cooling cycles, RS yield was also increased, regardless of isolation method. Enzymatic-gravimetric method severely hydrolyzed amorphous region of autoclaved maize starches. Crystalline region was obtained more effectively by enzymatic-gravimetric method than by ${\alpha}-amylase$ treatment.

  • PDF

Accurate Measurement of Arsenic in Laver by Gravimetric Standard Addition Method Combined with High Resolution Inductively Coupled Plasma Mass Spectrometry

  • Lee, Kyoung-Seok;Kim, Hyeon-Ji;Yim, Yong-Hyeon;Kim, Jeongkwon;Hwang, Euijin
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • A gravimetric standard addition method combined with internal standard calibration has been successfully developed for the accurate analysis of total arsenic in a laver candidate reference material. A model equation for the gravimetric standard addition approach using an internal standard was derived to determine arsenic content in samples. Handlings of samples, As standard and internal standard were carried out gravimetrically to avoid larger uncertainty and variability involved in the volumetric preparation. Germanium was selected as the internal standard because of its close mass to the arsenic to minimize mass-dependent bias in mass spectrometer. The ion signal ratios of $^{75}As^+$ to $^{72}Ge^+$ (or $^{73}Ge^+$) were measured in high resolution mode ($R{\geq}10,000$) to separate potential isobaric interferences by high resolution ICP/MS. For method validation, the developed method was applied to the analysis of arsenic content in the NMIJ 7402-a codfish certified reference material (CRM) and the result was $37.07mg{\cdot}kg^{-1}{\pm}0.45mg{\cdot}kg^{-1}$ which is in good agreement with the certified value, $36.7mg{\cdot}kg^{-1}{\pm}1.8mg{\cdot}kg^{-1}$. Finally, the certified value of the total arsenic in the candidate laver CRM was determined to be $47.15mg{\cdot}kg^{-1}{\pm}1.32mg{\cdot}kg^{-1}$ (k = 2.8 for 95% confidence level) which is an excellent result for arsenic measurement with only 2.8 % of relative expanded uncertainty.

Development of Hybrid Geoid using the Various Gravimetric Reduction Methods in Korea (다양한 중력학적 환산방법을 적용한 한국의 합성지오이드 개발)

  • Lee, Dong-Ha;Lee, Suk-Bae;Kwon, Jae Hyoun;Yun, Hong-Sic
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5D
    • /
    • pp.741-747
    • /
    • 2008
  • Nowadays, the accuracy of the geoid model has been improved through development of the combination model which was composed of traditional gravimetric geoid and geometric geoid by the GPS/leveling data in USA and Japan. It is a state of the art method in geoid modeling field that what so called hybrid geoid. In this paper, as a basic study to develop Korean hybrid geoid model, we studied gravimetric geoid solutions using three gravity reduction methods (Helmert's condensation method, RTM method and Airy-isostatic method) and evaluated the usefulness of each method in context of precise geoid. The gravimetric geoid model were determined by restoring the gravity anomalies (included TC) and the indirect effects were made from various reduction methods on the EIGEN-CG03C reference field. The results are compared with respect to the geometric geoid undulation determined from 498 GPS/leveling after LSC fitting. The results showed that hybrid geoid with RTM (Residual terrain model) reduction method was most accurate method and the value of the difference compared to geometric geoid was $0.001{\pm}0.053m$.

Improvement of Uncertainty for Gravimetric Flow Calibrator (10톤 용량의 중량식 교정장치에 대한 불확도 개선)

  • Lee, Dong-Keun;Park, Joo-Young;Lee, Haeng-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1042-1046
    • /
    • 2008
  • Both the weighing bridge and the diverter system is a important component in achieving a high accuracy liquid flow rate standard using a static gravimetric method. The weighing bridge is a tank which weighing collected flow with a load cells. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that the measurement deviation of load cell and uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

  • PDF

Characteristics of Uni-directional Diverter for Gravimetric Calibration Facility (액체용 중량식 유량계 교정장치의 일방향 Diverter 특성연구)

  • Nam, Ki Han;Park, Jong Ho;Kim, Hong Jip
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.59-64
    • /
    • 2017
  • Diverter is an essential element in gravimetric calibration method of flowmeter. Error of diverter are influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. That's why, time detection position of diverter is tuned through repetitive test for minimizing error of diverter. Further the diverter must be compared with the other institutions test since the influence on the accuracy of the flow meter used in the test. In this paper, errors (flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location) of diverter are decreased by produced uni-direction diverter and error of gravimetric calibration system is decreased. Uni-direction diverter is calibrated by gravimetric calibration system with precision flowmeter, the flowmeter is calibrated by pipe prover and other institutions and uni-direction diverter is evaluated. Uni-direction diverter is not influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. As a result, Uni-direction diverter can calibrate in wider scope since increasing ratio of maximum and minimum flow rate of uni-direction diverter.