• Title/Summary/Keyword: Grid connected

Search Result 1,221, Processing Time 0.036 seconds

Harmonic Impact Studies of Grid-Connected Photovoltaic Generation System (계통연계 태양광발전시스템 고조파 영향 검토)

  • Lee, Kang-Wan;Jung, Hyong-Mo;Lee, Sang-Min;Yu, Gwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1134_1135
    • /
    • 2009
  • 태양광발전 출력은 인버터를 통하여 상업용 전력계통에 연계된다. 소형 태양광발전 전력은 다수의 수용가를 포함하고 있는 기존의 22.9kV 배전선로에 직접 연결되며, 비선형 전력전자소자로 구성된 인버터는 고조파를 발생하게 된다. 본 논문은 태양광발전소 고조파를 실측하여 이를 모델로 연계 전력계통에 미치는 고조파 영향을 전력계통 해석 도구인 소프트웨어로 분석한 것이다.

  • PDF

A New Required Reserve Capacity Determining Scheme with Regard to Real time Load Imbalance

  • Park, Joon Hyung;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.511-517
    • /
    • 2015
  • Determination of the required reserve capacity has an important function in operation of power system and it is calculated based on the largest loss of supply. However, conventional method cannot be applied in future power system, because potential grid-connected distributed generator and abnormal temperature cause the large load imbalance. Therefore this paper address new framework for determining the optimal required reserve capacity taking into account the real time load imbalance. At first, we introduce the way of operating reserve resources which are the secondary, tertiary, Direct Load Control (DLC) and Load shedding reserves to make up the load imbalance. Then, the formulated problem can be solved by the Probabilistic Dynamic Programming (PDP) method. In case study, we divide two cases for comparing the cost function between the conventional method and the proposed method.

Development of Matrix Converter for Grid-Connected Wind Power Generation (풍력발전 계통연계를 위한 매트릭스 컨버터의 개발)

  • Choi, Nam-Sup;Li, Yulong;Han, Byung-Moon;Ko, Jong-Sun;Nho, Eui-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.208-210
    • /
    • 2007
  • As a renewable power source, wind power generation has been research interest for many years. And power electronic converters have been developed and applied in variable speed wind turbines. This paper presents the basic development and implementation of space-vector modulated three phase AC-AC matrix converter for variable speed wind power system. Basic matrix converter operation is described, where a new bidirectional switch structure with commutation circuit is used. Finally, experiment results of basic converter operation are shown.

  • PDF

Control of a Single Phase Unified Power Quality Conditioner-Distributed Generation Based Input Output feedback Linearization

  • Mokhtarpour, A.;Shayanfar, H.A.;Bathaee, M.;Banaei, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1352-1364
    • /
    • 2013
  • This paper describes a novel structure for single phase Unified Power Quality Conditioner-Distributed Generation (UPQC-DG) with direct grid connected DC-AC converter for low DC output DG systems which can be used not only for compensation of power quality problems but also for supplying of load power partly. This converter has been composed of one full-bridge inverter, one three winding high frequency transformer with galvanic isolation and two cycloconverters. Proper control based on Input Output feedback Linearization is used to tracking the reference signals. The simulation and experimental results are presented to confirm the validity of the proposed approach.

Stability Improvement of Battery Energy Storage System considering Synchronous Inductance Effect of Diesel Generator

  • Jo, Jongmin;An, Hyunsung;Chun, Kwan-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2254-2261
    • /
    • 2018
  • This paper analyzes stability of current control in respect of four cases of battery energy storage system (BESS) in a stand-alone microgrid. The stand-alone microgrid is composed of BESS, diesel generator and controllable loads, where all of them have a rated power of 50kW. The four cases are considered as following: 1) BESS with a stiff grid 2) BESS with the diesel generator 3) BESS with passive damping + diesel generator 4) BESS with active damping + diesel generator, and their stabilities are analyzed in the frequency domain and discrete time domain. The comparative analysis for four cases are verified through simulation and experiments through demonstration site of the stand-alone microgrid, where the DC link is connected to a 115kW battery bank composed of 48 lead-acid batteries (400AH/12V). Experimental results show a good agreement with the analysis.

Development of the Wind Power Simulator Connected to the Grid (계통연계형 풍력발전 시뮬레이터 개발)

  • Choy, Young-Do;Jeon, Young-Soo;Jeon, Dong-Hoon;Sin, Jeong-Hun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.542-545
    • /
    • 2009
  • 고창의 전력품질 실증시험장에서 계통에 연계된 풍력발전 시뮬레이터를 이용하여 풍력발전기의 특성을 파악하기 위해, 가변 풍속에서 이중여자 풍력발전기의 회전속도와 유효전력의 변화가 계통에 미치는 영향을 분석하였다. 고창의 전력품질 실증시험장은 22.9kV 계통에 전력품질 향상기기(DVR, STATCOM, SSTS)와 전력품질 외란 발생장치 등이 구축되어 있다. 모터와 VVVF를 이용하여 풍력발전기의 블레이드를 구현하고, 유도형과 이중여자 유도형 풍력발전기를 모의할 수 있는 시뮬레이터를 개발하였다. 선로의 길이를 20 kM로 가정하고, 덕적도의 풍속데이터를 이용한 가변풍속 패턴을 설정하여 풍력발전기의 회전속도에 대한 출력특성을 확인하였다.

  • PDF

Analysis of Photovoltaics RD & D Programs and Industry Growth in Japan (일본 태양광 산업 발전 및 기술 개발 성과의 시사점)

  • Lim, Hee-Jin;Yoon, Kyung-Shick;Jang, Hyuk-Bong;Kim, Dong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.269-275
    • /
    • 2007
  • 태양광 분야에서 일본은 기술 및 보급에 성공한 대표적인 사례로서 거론된다. 태양광의 에너지자원화를 목표로 30여 년간 지속적으로 국가차원의 기술개발 및 보급을 정책 사업화하여 진행시켰고 성공적인 선행 단계를 밟아 왔다. 현재까지의 성공을 기반으로 [태양광 비전 2030]을 수립하여 실현가능한 장기 목표를 구체화하는 단계에 있다. 이에 일본 태양광 산업 및 기술개발 방향에 대한 분석을 통해 오늘 우리에게 주는 시사점을 도출하여 차세대 성장 동력 산업이 될 국내 태양광분야의 발전을 위한 지표로 삼고자 한다.

  • PDF

Flow Control for Fuel Cell System with DSP Controller (DSP Controller를 적용한 연료전지 시스템의 유량 제어)

  • Shin, Bum-Su;Choi, Dong-Min;Han, Se-Young;Lee, Ho-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.184-187
    • /
    • 2007
  • 본 논문은 DSP Controller를 적용한 연료전지시스템의 유량제어에 관한 논문이다. 그리고 이 연구에서 사용된 시스템은 1kW급 계통연계 연료전지 시스템이다. 이 연료전지 시스템이 안정적으로 전원을 공급할 수 있도록 시스템에서 요구하는 공기 유량을 정확히 공급하도록 제어하는 것이 본 연구의 목적이다. 이 목적을 이루기 위해 공기 공급 장치에 PID 제어기를 설계하여 적용하였다. PID 제어기의 Gain값은 지글러 니콜스 Tuning 방식으로 정하였다. 이 제어기를 적용하여 실험한 결과, 적용 전 상태와 비교하면 맥동이 30% 저감하였고, 정상상태 오차가 제거되어 온도 변화와 같은 외란과 상관없이 정확한 요구 공기 유량을 공급함을 확인할 수 있었다. 그리고 부하가 변동함에 따라 해당 요구 공기 유량이 바뀔 때 1초 내에 그 요구 공기 유량을 추종하여 스택이 안정적으로 운전될 수 있도록 하였다.

  • PDF

Development of a Parallel Inverter for 2 MW Windpower Generator (2 MW 풍력발전기용 병렬형 Inverter 개발)

  • Choi, Hyo-Jin;Kwon, Sei-Jin;Son, Yoon-Gyu;Suh, Jae-Hak;Jang, Sung-Duk;Oh, Jong-Seok;Kang, Sin-Il;Lee, Hyun-Young;Kwon, Oh-Jung;Lee, Byung-Chul;Hwang, Jin-Su;Ryu, Ji-Yoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.427-431
    • /
    • 2007
  • 본 논문에서는 750 kW 풍력발전용 인버터를 개발한 결과와 2년 동안의 현장실증을 통하여 얻어진 경험을 바탕으로 2 MW 영구자석형 동기발전기(PMSG, Permanent Magnet Synchronous Generator)의 전력변환을 위한 병렬형 인버터의 시뮬레이션과 이를 통한 설계와 제작 및 기본시험 과정을 소개하고자 한다.

  • PDF

A Phase Detection Method in Grid-Connected Converters using Oberber (관측기를 이용한 계통 연계형 컨버터에서 위상검출 방법에 대한 연구)

  • Kim, Young-Chun;Cho, Moon-Tack;Song, Ho-Bin;Kim, Ok-Hwan;Hong, Soon-Jik;Joo, Hae-Jong;Lee, Euy-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.796-799
    • /
    • 2012
  • 직류전원장치에 사용되는 계통연계형 컨버터는 전원의 위상을 기준으로 제어되어야 하므로 하드웨어 또는 소프트웨어적인 다양한 방법들이 사용되고 있다. 이러한 방법들은 복잡하거나 노이즈에 의한 오동작 등의 위해요소를 내포하고 있다. 이에 본 논문에서는 관측기를 이용하여 전원의 주파수 변동에도 사용할 수 있는 강인한 위상점지 방법에 대해 제안하고 실험을 통해 입증하였다.

  • PDF