• 제목/요약/키워드: Grid-connected PV System

검색결과 234건 처리시간 0.038초

태양광 전원과 리튬 에너지 저장장치의 연계운전시 특성 해석 (Analysis of Connected Operations of PV Source and Li Energy Storage Equipment to Power System)

  • 김덕영
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.106-112
    • /
    • 2014
  • This paper presents the analysis of connected operation of photo voltaic source and Li energy storage system. The micro-grid has been installed and operated for several years at the campus of USF and has been a role of test bed. Photo voltaic source has been strongly influenced by the location, weather and climate of a installed area and Li battery is connected directly to the photo voltaic source to compensate for the limitations. The Li battery is operated to supply power output to the grid by the charging or discharging mode based on the average power output of the PV source which is calculated from monitored data for several years. The load of the PV and Li battery system is operated as a severe loading condition and the operating characteristics of PV source and Li battery are analyzed in detail. In connected operations of PV and Li battery to power system, the PV and Li battery is operated to supply constant power during only day time or peak time to increase load shedding ratio and efficient usage of generation sources in power system.

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

디커플링과 에너지 저장 기능을 갖는 계통 연계형 PV-AC Module용 플라이백 인버터 (Grid-connected PV-AC module with Decoupling and Energy Storage Functions using Flyback Inverter)

  • 류무영;오민석;노용수;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.475-476
    • /
    • 2013
  • In single-phase flyback inverter for grid-connected PV-AC module, power ripple is occurred as two times grid frequency on input capacitor. So, decoupling method has attracted interest recently. Also, power generation of PV depending on irradiation is limited at particular time, so use of energy storage system can increase energy efficiency. In this paper, flyback inverter for grid-connected PV-AC module which can operate decoupling and energy storage functions is proposed and verified by PSIM simulation.

  • PDF

Performance Analysis of Grid-Connected PCS for PV System by Field Demonstration Test

  • So J.H.;Jung Y.S.;Yu G.J.;Jung M.W.;Kang G.H.;Choi J.Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.516-519
    • /
    • 2003
  • 3kW photovoltaic (PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center (FDTC) of Korea. As climatic and irradiation conditions are varied, the performance characteristics of PV system are collected and analyzed in data acquisition system. From these results, the performances of gird-connected power conditioning system (PCS) fur PV system have been evaluated and analyzed. Furthermore, performance indices of grid-connected PCS e.g. output power, efficiency, loss factor, and the other index at the site are reviewed.

  • PDF

계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석 (Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior)

  • 김응상;김슬기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2193-2194
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.561-562
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic(PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power Quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD) The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1227-1228
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic(PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1687-1688
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that tan occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계헝 태양광인버터의 PV Array 출력리플 저감을 위한 연구 (Study for Reducing Ripples of the PV Array Output in Grid-Connected Photovoltaic Power System)

  • 김희중;정용호;이기수;전영수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.202-205
    • /
    • 2006
  • In the PV power system, output of the PV array must contain inherent ripples due to the single-phase inverter. So the function of maximum power point tracking to increase the output efficiency of PV system is degraded. Therefore, to overcome this problem, this paper presents a control strategy for the reducing ripples of the PV array output in grid-connected photovoltaic power system. The proposed control system consists of two loops the maximum power point tracking loop using the perturbation and observation method is used to calculate the reference solar array terminal voltage(Vref) for reducing ripples of the PV array output and the PI control loop is used to regulate the solar array output voltage according to the Vref. The performance of proposing control strategy is analyzed by means of the PSCAD/EMTDC simulation. As a result, we may obtain the high performance of the proposed control strategy.

  • PDF