• Title/Summary/Keyword: Ground spray

Search Result 79, Processing Time 0.021 seconds

Application Cases of Test Construction of Hydro-Seeding Measures on the Slopes Along the National Road Between Gamchon and Yaechon (감천예천구간 국도비탈면 종자뿜어붙이기 시험시공 적용사례)

  • Jeon, Gi-Seong;Woo, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.6
    • /
    • pp.139-151
    • /
    • 2007
  • To protect the surface of ground-cutting slopes and ground-raised slopes and to recover environment-friendly slopes at the national road expansion construction between Gamchon and Yaechon, test-construction work was done using several modes of hydro-seeding measures to select a suitable construction method through the field survey; the results were as follows : As a result of survey on physio-chemical characteristics of soil, the average soil inclination on ground-raised slopes was from 4.73 mm to 5.37 mm; the average soil acidity was from pH 6.47 to 6.73; the average soil humidity was within the scope of 0.57~1.70 %,; the average soil inclination on ground-cutting slopes was 9.17~10.43mm; the average soil acidity was pH 6.67~6.77 and the average soil humidity was within the scope of 0.53~1.27 %; considered overall, they showed generally satisfactory base materials for plant breeding. As a result of the number of sprouting individuals, the average sprouting number of individuals on test spots executed by Coir net with Seed spray construction methods and the average number of sprouting individuals on other test spots executed by furrow-digging with Seed spray and Straw mat-mulching measures were 1,172 number of per square meter and 970 number of per square meter respectively; thus they showed higher numerical value comparing with other test spots. Likewise, the average number of sprouting individuals on test spots of the ground-cutting slopes executed by Coir net with Seed spray method and the average number of sprouting individuals on other test spot executed by furrow-digger with Seed spray and Straw mat-mulching measures were found to be 1,107 number of per square meter and 1,105 number of per square meter respectively, whose numerical value showed rather higher other test spots. As a result of a survey on living plants' breeding index [dried weight], the weight in dried state on test spots executed by Coir net with Seed spray method and other test spots executed by furrow-digger with Seed spray and Straw mat-mulching measures on both ground-raised and ground-cutting slopes was found to be higher and showed similar characteristics statistically. As a result of survey on the surface-covering degree of ground-raised slopes, nine weeks after test construction, test spots executed by Coir net with Seed spray method and other test spots executed by furrow-digger with Seed spray and Straw mat-mulching measures showed commonly more than 70% of surface-covering degree, but other test spots showed only below 35% of surface covering degree; especially in case of test spots by Verdvol seed spray measures, they showed 10% of the lowest surface-covering. Surface-covering degree on the test spot of ground-cutting slopes nine weeks after test construction showed more than 75% both executed by Coir net with Seed spray construction method and executed by furrow-digger with Seed spray and Straw mat-mulching measures. As a result of survey on appearing plants on the test spots, there dominates Eragrostis curvula both on ground-raised slopes and on ground-cutting slopes with other seeding plant life's lower breeding and there appear intruders, such as Setaria viridis Beauv, Digitaria sanguinalis Scop, and Chenopodium album var.centrorubrum Makino. As for water-borne excavation and soil's washing-away on the slopes, there happened less washing-away and water-borne excavation with good breeding of plant life on test spots executed both by Coir net with Seed spray construction method and by furrow-digger with Seed spray and Straw mat-mulching measures, but there happened much more soil's washing-away along with water-home excavation at the test spot executed by Seed spray with measures. After the research results of test construction sites are examined overall, it's presumed that furrow-digger with Seed spray and Straw mat-mulching measures [interval between lines is 40cm, 5cm in depth] will be preferred to prevent erosion and water-home excavation of slopes located within the construction sites.

Study on Behavior of Spray and Spark Channel by Air Flow Characteristics According to Operating Conditions in Gasoline Direct Injection Engine (가솔린 직분사 엔진에서 운전 조건에 따른 공기 유동 특성에 의한 분무 거동 및 점화 채널에 관한 연구)

  • Hoseung Yi;Sungwook Park
    • Journal of ILASS-Korea
    • /
    • v.28 no.4
    • /
    • pp.198-206
    • /
    • 2023
  • In this study, visualization of in-cylinder spray behavior and spark channel stretching by air flow characteristics depending on engine operating conditions were investigated. For in-cylinder spray behavior, increase in engine rpm did not alter the counter-clockwise air flow direction and location of in-cylinder dominant air flow but increased average air flow velocity, which hindered spray propagation parallel to the piston surface. When injection timing was retarded, direction of in-cylinder dominant air flow was changed, and average air flow velocity was reduced resulting in an increase in spray penetration length and change in direction. For spark channel stretching, increase in air flow speed did not affect spark channel stretch direction but affected length due to increase in spark channel resistance and limitation of energy ignition coil can handle. Change in air flow direction affected spark channel stretch direction where the air flow was obstructed by ground electrode which caused spark channel direction to occur in the opposing direction of air flow. It also affected spark channel stretch length due to change in air flow speed around the spark plug electrode from the interaction between the air flow and ground electrode.

Assessment of Dispersion Coefficients and Downward Positions of Water Spray for Small-Scale Release of Chlorine Gas

  • Jang, Seo-Il;Kim, Youngran;Yu, Wooyun;Shin, Dongil;Park, Kyoshik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • To assess downward positions of water spray for the small-scale release of chlorine gas, dispersion coefficients for the Gaussian dispersion model were validated at the small-scale release experiment. And the downwind distances of water spray were assessed with the simulated results. As results, the Gaussian plume model using the Briggs' dispersion coefficient well estimated the dispersed characteristics for small-scale release of chlorine gas. The best adequate downwind position of water spray is the position of the maximum concentration of chlorine at the ground level. And the adequate vertical and horizontal dimensions of water spray consider the maximum width and height of cloud.

Use of Sprinkler System for Control of Pine Needle Gall Midge, Thecodiplosis japonensis Uchida et Inouye -II. Effectiveness of Ground Application with Low Concentration of Insecticides (분무장치(噴霧裝置)를 이용(利用)한 솔잎혹파리 방제(防除)에 관(關)한 연구(硏究) -II. 저농도(低濃度) 지면약제살포(地面藥劑撒布) 효과(效果) -)

  • Chung, Sang Bae
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.4
    • /
    • pp.571-576
    • /
    • 1998
  • Experiments were conducted to evaluate the efficacy of the application of low concentration insecticides by sprinkler system for control of the pine needle gall midge, Thecodiplasis japonensis, by killing the adults emerging and copulating near the ground. For ground spray, 2 insecticides of fenitrothion and deltamethrin, dilutions of $2,000{\times}$ and $3,000{\times}$ deltamethrin, and 3 spray intervals of 1-3 day were tested at the peak time of adult emergence during the day time. The results are as follows ; 1. Ground spray of fenitrothion 50% EC and deltamethrin 1% EC were found to be highly effective for control of the pine needle gall midge. Average gall formation by fenitrothion, deltamethrin and untreated ones were 3.40%, 5.23% and 45.69%, respectively ; control value of both insecticides exceeded 88%. 2. As a ground spray of deltamethrin 1% EC, dilution $2,000{\times}$ was significantly different from $3,000{\times}$ in gall formation rates. Average gall formation of $2,000{\times}$ plots and $3,000{\times}$ treated ones were 5.23% and 18.00% ; control values were 89.44% and 63.66%, respectively. 3. Diurnal treatment of ground spray was found to be highly effective for control of pine needle gall midge. 4. In particular, control by ground application of dilutions $2,000{\times}$ and $3,000{\times}$ of deltamethrin is suggested because it does not have an adverse effect on arthropods of the ground surface such as ants and spiders.

  • PDF

Spray Deposit Distribution of a Small Orchard Sprayer (소형 과수방제기 살포입자의 부착량 분포)

  • Koo, Young-Mo
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.145-152
    • /
    • 2007
  • Uniformity of spray deposit is one of the important factors in spray performance affecting efficacy of pest management. Distributions of spray deposit on artificial targets were measured and analyzed to enhance the efficiency of spray application. The research was studied to understand the deposition characteristics of spray droplets and to determine the optimum conditions of chemical application. The deposit and its pattern by the lower fan speed was more uniform and higher than that by the higher fan speed. The upward blasting distance was limited within 3 m, but the limit to the ground level was expanded the distance more than 3.5 m because of the accumulated droplets. When the fan speed was higher at the distance of 2.5 m, deposit reached to maximum. When the distance increased, deposit was getting lower. At the both fan speeds, the deposit was concentrated below $30^{\circ}$ because of the gravitation and the resistance of wind. This research can be useful in designing an orchard sprayer and its operation for various tree canopies. To achieve a uniform distribution of deposit using the air-blast type orchard sprayer, the application rate from the middle boom should be increased as the air velocity to the upward increased. The spray rate to the side boom should be limited in a minimal level.

Use of Sprinkler System for Control of the Pine Needle Gall Midge, Thecodiplosis japonensis Uchida et Inouye (분무장치(噴霧裝置)를 이용(利用)한 솔잎혹파리 방제(防除)에 관(關)한 연구(硏究))

  • Chung, Sang Bae;Kim, Chul Su
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.3
    • /
    • pp.311-321
    • /
    • 1994
  • Experiments were conducted to evaluate the efficacy of ground and foliar sprinkling of natural water for control of the pine needle gall midge, Thecodiplosis japonensis, by disturbing the reproductive behavior of adults such as copulation and oviposition. Diurnal ground spray for whole area application and foliar spray for single tree treatment were tested at day time during the period of adult emergence. The results obtained are as follows : 1. The population density of overwintering larvae in soil was not affected by the water spray during the adult emergence period. 2. Spraying the water showed no effect on the whole period and number of adult emergence, but retarded early emergence and facilitated Late emergence. The difference in the emerging time by 50% emergence day was approximately 7 days. 3. Ground spray was significantly different from control in gall formation rates but was not sufficient for effective control. As a single-tree treatment, the foliar spray was found to be highly effective for control of the pine needle gall midge, Average gall formation of spray plots and untreated ones were 2.6% and 38%, respectively ; control value exceeded 90%. 4. Ground spray of water was not effective in reducing larvae in gall of needle. Foliar spray, however, reduced 45% of larval numbers. 5. Foliar spray accelerated shoot growth by 15%-18%. 6. Foliar spray was highly effective for the control of sucking insects, such as mites and aphids on pine trees.

  • PDF

MICROMETEOROLOGY IN PADDY FIELD AND ITS APPLICATION TO ESTIMATION OF SPRAY DRIFT

  • J. Y. Rhee;E. S. An;Kim, Y. J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.749-756
    • /
    • 2000
  • Chemical application, one of the most important crop management processes happened to cause spray drift, that would threaten farmers in field as well as dwellers in rural region. Spray drift was affected by micro-meteorological parameters. In Korea, a boom sprayer was introduced but good effects of a boom sprayer was not evaluated. A study to evaluate short distance drift characteristics of a boom sprayer in paddy fields has been undergoing and determining wind characteristics in paddy field was the main purpose of this paper. Micro-meteorological information has been pre-requisite information for evaluating drift in both long and short distances or in both theoretical and experimental ways. Wind velocity, Reynolds stresses, turbulence intensity, skewness, kurtosis etc. were evaluated with height from the ground using a 2-dimensional probe and a hot wire anemometer system.

  • PDF

Spray Pattern Analysis for a Centrifugal Fertilizer Distributor with Two Shutter Holes (두 개의 셔터 구멍이 적용된 원심식 비료 살포기의 살포패턴 분석)

  • Hwang, Seok-Joon;Park, Jeong-Hyeon;Lee, Ju-Yeon;Kim, Ki-Duck;Shin, Beom-Soo;Nam, Ju-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.8-19
    • /
    • 2019
  • In this study, the spray pattern of a centrifugal fertilizer distributor with two shutter holes was analyzed and an effective driving width that satisfies proper spray uniformity was derived. The centrifugal fertilizer distributor was mounted on a tractor with a rated power of 23.7 kW and static and dynamic spray pattern tests were performed according to the standard procedure proposed by the American Society of Agricultural and Biological Engineers Standard ASAE S341.5. The height of the fertilizer distributor was 80 cm from the ground and the PTO (power take-off) shaft speed of the tractor was fixed at 540 rpm. The fertilizer scattered in space was collected using 275 evenly spaced collectors at shutter opening ratios of 25%, 50%, 75%, and 100%. The spray pattern was analyzed via the amount of sprayed fertilizer at each collector location and the coefficient of variation was used as an indicator of spray uniformity. Using the analyzed spray pattern, the effective driving width that satisfied less than 15% of the coefficient of variation was derived for different tractor driving patterns (race track mode, back and forth mode). From the results, spray uniformity increased as the shutter opening ratio decreased. The largest effective driving width was 8 m at a shutter opening ratio of 25% for both driving patterns.

Analyzing Drift Patterns of Spray Booms with Different Nozzle Types and Working Pressures in Wind Tunnel (풍동실험에 의한 붐식 살포 농약의 노즐형태와 분사압력에 따른 비산 특성 분석)

  • Park, Jinseon;Lee, Se-Yeon;Choi, Lak-Yeong;Jeong, Hanna;Noh, Hyun Ho;Yu, Seung-Hwa;Song, Hosung;Hong, Se-woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.5
    • /
    • pp.39-47
    • /
    • 2021
  • With rising concerns about pesticide spray drifts, this study analyzed the drift patterns of two typically-used nozzles, XR nozzle and AI nozzle, concerning their working pressures and wind speeds by wind tunnel experiments. AI nozzle showed low drift potential with larger droplet sizes compared to XR nozzle. Airborne and deposition drifts of XR nozzle were two times higher than those of AI nozzle under high wind speeds (≥2 m s-1). In all cases, higher working pressures decreased the droplet sizes, thereby increasing the airborne and deposition drifts. Higher wind speeds also resulted in more airborne drifts, while ground deposition was increased under lower wind speeds. These effects of working pressures and wind speeds on the airborne and deposition drifts were observed at leeward distances less than 4 m from the nozzles. However, the airborne and deposition drifts were barely affected by the working pressures and wind speeds at leeward distances more than 11 m. The measurements were fitted to regression models of the drift curve with acceptable R2 values greater than 0.8, demonstrating that further studies will be useful to settle domestic issues of spray drifts.

Uniformity Analysis of Unmanned Aerial Application with Variable Rate Spray System (무인항공 변량방제 시스템의 살포 균일도 분석)

  • Koo, Young Mo;Bae, Yeonghwan
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.111-125
    • /
    • 2018
  • In this study, we evaluated the uniformity of deposition rate and particle size distributions of the variable rate application technique using the unmanned rotorcraft by measuring the spray pattern according to path location in the range of spraying flight. The coefficient of variation (CV) of the lateral coverage rate for the overlapped distribution with the spray swath of 3.6 m in both guidance and auto-pilot flight modes maintaining constant flight speed was about 30% and the CV of the coverage rate by the flight path location was extremely small. Therefore, it was assessed that the variable rate application technology compensating for the variation of ground speed was superior in terms of spray uniformity. In addition, the droplet size distributions in both volume median diameter(VMD) and number median diameter(NMD) were adequate for aerial application and uniform in terms of lateral distribution. Thereafter, we intend to contribute to a precise application on small-scaled fields using the unmanned agricultural rotorcraft by the variable rate application.