• 제목/요약/키워드: Group-bolted connection

검색결과 6건 처리시간 0.019초

외부마감재가 부착된 볼트접합 방식 패널링 시스템의 내진성능평가를 위한 진동대 실험 (Shake Table Test on Seismic Performance Evaluation of the Bolted Connection Type Paneling System with Exterior Finish Material)

  • 오상훈;박종원;박해용
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.23-32
    • /
    • 2018
  • In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.

볼트 전단파단이 지배하는 지압형식 볼트접합부의 힘-변형 관계 (Force-Deformation Relationship of Bearing-Type Bolted Connections Governed by Bolt Shear Rupture)

  • 김대경;이철호;진승표;윤성환
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2015
  • 잘 접합된 볼트접합부는 볼트의 전단파단이 발생할 때 까지 지압 메커니즘에 의하여 훌륭한 연성거동을 보인다. 이러한 볼트접합부에 내재된 연성 능력을 최대한 활용한다면 중력하중, 풍하중, 지진하중 등 다양한 하중에 대하여 활용하여 접합비용의 경제성 제고에 기여할 수 있다. 편심하중을 받는 볼트접합부의 경우 보수적인 탄성해석법과 합리적으로 볼트접합부의 연성거동을 활용할 수 있는 극한강도 해석법이 존재하나 기존의 극한강도해석법은 오늘날 다양한 소재와 설계조건의 다양화에도 불구하고 하나의 소재와 조건으로 이루어진 실험식에 의존하고 있다. 본 연구의 주된 목적은 체계화된 단일볼트의 실험을 기반으로 볼트의 일반화된 힘-변형 관계식을 정립하는 것이다. 실험결과를 토대로 볼트접합부의 기하학적인 요소(볼트의 직경, 플레이트의 두께) 및 강도가 힘-변형 관계에 주된 영향을 미치는 요소라는 것을 알 수 있다. 실험결과를 순간중심회전법에 적용하여 보다 정확하고 경제적인 편심하중을 받는 군볼트 접합부 설계가 가능하다.

단일볼트 지압접합부의 힘-변형관계 (Load-Deformation Relationship of Single Bolted Connections)

  • 김대경;이철호;진승표;윤성환
    • 한국강구조학회 논문집
    • /
    • 제29권5호
    • /
    • pp.341-352
    • /
    • 2017
  • 강구조물을 접합하는 대표적인 두 가지 방법으로는 용접접합과 볼트접합이 있다. 이중 잘 접합된 볼트접합은 지압메카니즘에 의한 강도상승과 연성거동을 기대할 수 있다. 이러한 볼트접합부의 연성능력을 충분히 활용하기 위해 본 연구에서는 합리적인 단일볼트접합부의 힘-변형관계 및 지압강도 산정식을 제안하고자 하였다. 볼트접합부의 경계조건 및 기하학적인 요소를 고려하여 체계적으로 단일볼트 실험을 수행하였다. 현행 설계기준의 볼트접합부의 지압강도 산정식의 모순점을 해결하기 위해 새로운 지압강도 설계식 및 변형한계 산정식을 제안하였다. 또한 접합부의 강성, 강도, 기하학적 조건 등을 반영할 수 있는 힘-변형관계식을 제안하였다. 본 연구에서 제시한 지압강도식 및 힘-변형관계식은 현행설계기준보다 합리적으로 실험결과를 예측하였다.

EMI based multi-bolt looseness detection using series/parallel multi-sensing technique

  • Chen, Dongdong;Huo, Linsheng;Song, Gangbing
    • Smart Structures and Systems
    • /
    • 제25권4호
    • /
    • pp.423-432
    • /
    • 2020
  • In this paper, a novel but practical approach named series/parallel multi-sensing technique was proposed to evaluate the bolt looseness in a bolt group. The smart washers (SWs), which were fabricated by embedding a Lead Zirconate Titanate (PZT) transducer into two flat metal rings, were installed to the bolts group. By series connection of SWs, the impedance signals of different bolts can be obtained through only one sweep. Therefore, once the loosening occurred, the shift of different peak frequencies can be used to locate which bolt has loosened. The proposed multi input single output (MISO) damage detection scheme is very suitable for the structural health monitoring (SHM) of joint with a large number of bolts connection. Another notable contribution of this paper is the proposal of 3-dB bandwidth root mean square deviation (3 dB-RMSD) which can quantitatively evaluate the severity of bolt looseness. Compared with the traditional naked-eye observation method, the equivalent circuit based 3-dB bandwidth can accurately define the calculation range of RMSD. An experiment with three bolted connection specimens that installed the SWs was carried out to validate our proposed approach. Experimental result shows that the proposed 3 dB-RMSD based multi-sensing technique can not only identify the loosened bolt but also monitor the severity of bolt looseness.

Detection and location of bolt group looseness using ultrasonic guided wave

  • Zhang, Yue;Li, Dongsheng;Zheng, Xutao
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.293-301
    • /
    • 2019
  • Bolted joints are commonly used in civil infrastructure and mechanical assembly structures. Monitoring and identifying the connection status of bolts is the frontier problem of structural research. The existing research is mainly on the looseness of a single bolt. This article presents a study of assessing the loosening/tightening health state and identifying the loose bolt by using ultrasonic guided wave in a bolt group joint. A bolt-tightening index was proposed for evaluating the looseness of a bolt connection based on correlation coefficient. The tightening/loosening state of the bolt was simulated by changing the bolt torque. More than 180 different measurement tests for total of six bolts were conducted. The results showed that with the bolt torque increases, value of the proposed bolt-tightening index increases. The proposed bolt-tightening index trend was very well reproduced by an analytical expression using a function of the torque applied with an overall percentage error lower than 5%. The developed damage index based on the proposed bolt-tightening index can also be applied to locate the loosest bolt in a bolt group joint. To verify the effectiveness of the proposed method, a bolt group joint experiment with different positions of bolt looseness was performed. Experimental results show that the proposed approach is effective to detect and locate bolt looseness and has a good prospect of finding applications in real-time structural monitoring.

Behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 2: Evaluation of theoretical strength

  • Zhu, Y.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • 제34권5호
    • /
    • pp.563-580
    • /
    • 2010
  • Composite beams using bolts to attach steel plates to the side faces of existing reinforced concrete (RC) coupling beams can enhance both their strength and deformability. The behavior of those composite beams differs substantially from the behavior of typical composite beams made up of steel beams and concrete slabs. The former are subjected to longitudinal, vertical and rotational slips, while the latter only involve longitudinal slip. In this study, a mixed analysis method was adopted to develop the fundamental equations for accurate prediction of the load-carrying capacity of steel plate strengthened RC coupling beams. Then, a rigid plastic analysis technique was used to cope with the full composite effect of the bolt group connections. Two theoretical models for the determination of the strength of medium-length plate strengthened coupling beams based on mixed analysis and rigid plastic methods are presented. The strength of the strengthened coupling beams is derived. The vertical and longitudinal slips of the steel plates and the shear strength of the anchor-bolt connection group is considered. The theoretical models are validated by the available experimental results presented in a companion paper. The strength of the specimens predicted from the mixed analysis model is found to be in good agreement with that from the experimental results.