• Title/Summary/Keyword: HPLC

Search Result 5,992, Processing Time 0.031 seconds

Determination of Sulfur Dioxide in Pickles by Acid Distillation-HPLC Method and Monnier Williams Modified Method (산증류-HPLC법과 모니어윌리암스변법을 이용한 절임류중의 이산화황 함량 분석)

  • Jung, So-Young;Kim, Il-Young;Kim, Sung-Dan;Jang, Mi-Ra;Chang, Min-Su;Han, Ki-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1028-1032
    • /
    • 2003
  • To assess accurate methods for measuring sulfur dioxide residue in pickles, the acid distillation HPLC-UV method and Monnier Willams modified method were examined. By the acid distillation HPLC-UV method, sulfites released from pickles by acid distillation were absorbed in 1% triethanolamine solution and detected as sulfite ion by HPLC with UV monitoring at 240nm. An anion exchange column was employed with 1.8mM $Ma_2CO_3-1.7mM\;NaHCO_3$ solution as a mobile phase, $84.0{\sim}91.7%$ of sulfite added to pickled radish were recovered. Total sulfite levels from 48 kinds of pickles analyzed by acid distillation HPLC-UV was compared with those analyzed by the Monnier Williams modified method. The Monnier Williams modified method showed higher levels of sulfur dioxide than the acid distillation HPLC-UV method due to the presence of volatile acids in pickles. The concentration of sulfur dioxide was in the range of $N.D{\sim}173.05ppm$ in pickled radish and over 30ppm of sulfur dioxide from 3 samples by the acid distillation-HPLC-UV method.

Rapid Identification of Radical Scavenging Compounds in Blueberry Extract by HPLC Coupled to an On-line ABTS Based Assay and HPLC-ESI/MS

  • Kim, Chul-Young;Lee, Hee-Ju;Lee, Eun-Ha;Jung, Sang-Hoon;Lee, Dong-Un;Kang, Suk-Woo;Hong, Sae-Jin;Um, Byung-Hun
    • Food Science and Biotechnology
    • /
    • v.17 no.4
    • /
    • pp.846-849
    • /
    • 2008
  • This study employed high performance liquid chromatography (HPLC) coupled to an on-line $ABTS^+$ radical scavenging detection (RSD) system along with HPLC-electro spin impact/mass spectrometry (ESI/MS), to rapidly determine and identify antioxidant compounds occurring in blueberry extract. The extract was separated by HPLC, and then the radical scavenging activities of the separated compounds were evaluated by the on-line coupled $ABTS^+$-RSD system. The negative peaks of the $ABTS^+$-RSD system, which indicates the presence of antioxidant activity, were monitored by measuring the decrease in absorbance at 734 nm. The active components in the blueberry extract were identified by HPLC-ESI/MS using their MS spectra and retention times. According to the data acquired from the on-line HPLC-$ABTS^+$-based assay and HPLC-ESI/MS systems, the antioxidant compounds detected in the blueberry extract were identified as chlorogenic acid and 11 anthocyanins.

Separation Study of Cytosine and Guanine by HPLC and Aspen Chromatography (Aspen Chromatography 전산모사와 HPLC를 이용한 구아닌 시토신의 분리특성연구)

  • Park, Moon Bae;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.48 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • DNA structure studies attract many interests in pharmaceutical, biochemical and medical disciplines. Among them, base pairs play a vital role in biological information transfer. Therefore, they need to be analyzed in various ways and the pair of guaninine and cytosine is the present analytical object. Separation of guanine and cytosine was researched by Aspen chromatography simulator and HPLC(High Performance Liquid Chromatography) experiments. Aspen chromatography simulation resulted in various chromatograms with changes of sample concentration, eluent flow rate and number of plate. The resolutions and yields of guanine and cytosine were calculated to obtain a best separation condition. $C_{18}$ HPLC column and water/methanol/acetic acid mixture(90/10/0.2) were used for separation of guanine and cytosine. HPLC parameters(resolution and number of theoretical plate) were calculated under different flow rates and sample concentrations. Aspen chromatography simulation and HPLC experimental results were compared with fair agreement.

Application of Competitive ELISA Method for Estimation of Urinary Aflatoxin M1 Level (ELISA 방법을 이용한 요중 아플라톡신 M1 측정)

  • Kim, Yong-Dae;Kim, Heon
    • Journal of Life Science
    • /
    • v.23 no.2
    • /
    • pp.306-310
    • /
    • 2013
  • We compared the efficacy of the competitive ELISA method for measuring the level of urinary aflatoxin M1 (AFM1) with that of the HPLC-fluorescence detector (HPLC-FLD) method. The recovery rate of AFM1 with the ELISA method was 105% (73-124%), and the coefficient of variation of the analysis was 6.85%. The ELISA method showed a 0.20 pg/ml and 0.62 pg/ml limit of detection and limit of quantitation, respectively. In correlation analysis, the two methods showed a very strong and statistically significant correlation (R=0.96, p<0.01). However, in spite of the strong correlation, the ELISA method tended to overestimate the urinary AFM1 concentration compared to the HPLC-FLD method. These results suggest that the competitive ELISA method may be a useful technique for measuring the AFM1 level in high-throughput urine samples, but it needs to be corrected with a regression equation from regression analysis with the HPLC-FLD method.

Quantification of Arsenic Species in Some Seafood by HPLC-AFS (HPLC-AFS를 이용한 해산물 중 비소 화학종 분리정량)

  • Jeong, Seung-Woo;Lee, Chae-Hyeok;Lee, Jong-Wha;Jang, Bong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.496-503
    • /
    • 2021
  • Background: Considering the expenses of and difficulties in arsenic speciation by high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS), alternative measurement methods should be useful, especially for large-scale research and projects. Objectives: A measurement method was developed for arsenic speciation using HPLC-atomic fluorescence spectrometry (HPLC-AFS) as an alternative to HPLC-ICP-MS. Methods: Total arsenic and toxic arsenic species in some seafoods were determined by atomic absorption spectrometry coupled with hydride vapor generation (AAS-HVG) and HPLC-AFS, respectively. Recovery rate of arsenic species in seafood was evaluated by ultra sonication, microwave and enzyme (pepsin) for the optimal extraction method. Results: Limits of detection of HPLC-AFS for As3+, dimethylarsinate (DMA), monomethylarsonate (MMA) and As5+ were 0.39, 0.53, 0.60 and 0.64 ㎍/L, respectively. The average accuracy ranged from 97.5 to 108.7%, and the coefficient of variation was in the range of 1.2~16.7%. As3+, DMA, MMA and As5+ were detected in kelp, the sum of toxic arsenic in kelp was 40.4 mg/kg. As3+, DMA, MMA and As5+ were not detected in shrimp and squid, but total arsenic (iAS and oAS) content in shrimp and squid analyzed by AAS-HVG were 18.1 and 24.7 mg/kg, respectively. Conclusions: HPLC-AFS was recommendable for the quantitative analysis method of arsenic species. As toxic arsenic species are detected in seaweeds, further researches are needed for the contribution degree of seafood in arsenic exposure.

Content Comparative Analysis and Classification for Piniellia ternate, P. pedatisecta and Typhonium flagelliforme by HPLC-PDA analysis (HPLC-PDA를 이용한 반하, 호장남성, 수반하의 분류 및 함량분석)

  • Jo, Ji Eun;Lee, A Yeong;Kim, Hyo Seon;Moon, Byeong Cheol;Choi, Goya;Ji, Yunui;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.28 no.5
    • /
    • pp.95-101
    • /
    • 2013
  • Objectives : A quantitative method using high performance liquid chromatography with a photodiode array detector(HPLC-PDA) was established for the quantitative analysis of the four main compound and pattern analysis to classification Piiellia ternate, P. pedatisecta and Typhonium flagelliforme. Methods : The analytical procedure for the determination of P. ternata, together with the known main compounds uracil, uridine, guanosine and adenosine was established. Optimum HPLC-PDA separation of these P. ternata was possible on Luna C18(2) column material, using water and acetonitrile as mobile phase. The method was validated according to regulatory guidelines. In addition, this assay method were analyzed for the content of four main compound in P. ternata, P. pedatisecta and T. flagelliforme and by data obtained from the HPLC-PDA analysis was performed principal component analysis(PCA). Results : Validation results indicated that the HPLC method is well suited for the determination of the roots of P. ternata with a good linearity ($r^2$ > 0.999), precision and recovery rates. Analysis of HPLC-PDA, the average content of uracil, uridine, guanosine and adenosine was significantly higher in P. ternate>P. pedatisecta> T. flagelliforme order. The application of PCA to main compound data by HPLC-PDA permitted the effective discrimination among the three species. Conclusions : Analysis of both HPLC-PDA and PCA confirmed the fact that four main compound and pattern profiles of P. ternata, P. pedatisecta and T. flagelliforme were different from each other.

Determination of Soluble Carbohydrates in Soybean Seeds Using High Performance Liquid Chromatography with Evaporative Light Scattering Detection (증기화광산란 검출기를 이용한 콩 함유 수용성 탄수화물의 분석)

  • Kim, Gyeong-Ha;Hwang, Young-Sun;Ahn, Kyung-Geun;Kim, Gi-Ppeum;Kim, Min-Ji;Hong, Seung-Beom;Moon, Jung-Kyeong;Choung, Myoung-Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.7
    • /
    • pp.1062-1067
    • /
    • 2014
  • In the present study, a new analytical method was devised for the simultaneous determination of soluble carbohydrates in soybean seeds using high performance liquid chromatography/evaporative light scattering detection (HPLC/ELSD). The limit of quantification (LOQ) for soybean soluble carbohydrates ranged from 5.6~7.6 mg/kg using the HPLC/ELSD method and from 16.2~33.9 mg/kg using the high performance liquid chromatography/refractive index detection (HPLC/RID) method. Therefore, the HPLC/ELSD method was more sensitive than HPLC/RID. The precision values for retention time and peak area of the HPLC/ELSD method were evaluated by inter-day (n=5) and intra-day (n=10) assays using a standard solution. All precision values (CV<2.5%) for soybean soluble carbohydrates were acceptable and fulfilled international acceptance criteria. All linear calibration curves were obtained with a correlation coefficient of $R^2$ >0.999. The contents of soluble carbohydrates for the "Shingikong" (yellow soybean) and "Cheongjakong 3" (black soybean) samples were analyzed using the HPLC/RID and HPLC/ELSD methods. The difference in carbohydrate contents between the two detection methods was significant. Carbohydrate contents in the HPLC/ELSD method were higher than those in the HPLC/RID method. Overall, the HPLC/ELSD method showed satisfactory resolution with a favorable LOQ and reproducibility. Therefore, these results indicate that the HPLC/ELSD method may be applied to determine the contents of soluble carbohydrates in soybean seeds and related food stuffs.

Simple estimation of Langmuir Parameter by HPLC experiments (HPLC를 이용한 Langmuir Parameter의 추산)

  • Lee, Sun-Mook;Yoon, Tae-Ho;Kim, In-Ho
    • Clean Technology
    • /
    • v.9 no.2
    • /
    • pp.81-85
    • /
    • 2003
  • A simple method of isotherm determination for HPLC is discussed. The equilibrium-dispersive model describing the behavior of elution peaks in HPLC for single component is solved numerically by using PDE solver Macsyma$^{(R)}$(Macsyma Inc., Arlington, MA, USA.) and compared to the experimental data obtained in overloaded isocratic chromatography with caffeine as model species. The effect of sample concentration and flow velocity on the band profiles of elution peaks are described.

  • PDF

Investigation of Validation Guidelines for Performance Verification of High Performance Liquid Chromatograph (고성능 액체크로마토그래프 기기의 성능검증을 위한 밸리데이션 가이드라인에 대한 연구)

  • Yun, Won Nam;Lee, Beom-Gyu;Lee, Wonjae
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.362-368
    • /
    • 2013
  • High performance liquid chromatograph (HPLC) is the most frequently used analytical instrument in analytical laboratories for pharmaceutical analysis. In order to provide a high level of assurance for reliable data generated from the HPLC analysis, the performance qualification of the HPLC system is required. For this purpose, the performance of HPLC system should be regularly monitored by examining the key functions of the typical HPLC system (solvent delivery system, injector system, column oven, UV-VIS detector system). We have investigated the validation guidelines of the performance verification of these key modules for HPLC system. And we proposed and evaluated its validation guidelines and the related verification methods for pharmaceutical analysis that could be practically applied in Korea.

Development of simultaneous determination of vitamin A and E in infant formula by micro-HPLC (Micro-HPLC를 이용한 조제분유 중 비타민 A.E 동시분석법 개발)

  • Yun I-Ran;Choi You-Jeong;Lee Min-Kwon;Jeong Myeong-Ho;Kim Byeong-Hun
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.339-346
    • /
    • 2006
  • Semi-micro-HPLC using a column-switching technique was developed for simultaneous determination of vitamin A and E contents in infant formula. Vitamin A and E were extracted by PDA - HPLC with reversed phase column using organic solvent and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with hydrolysis method and rapid extraction. Developed method has many advantages of simple and rapid sample preparation and simultaneous determination of vitamin A and E by micro-HPLC using reversed phase column.