• Title/Summary/Keyword: Head CT

Search Result 553, Processing Time 0.028 seconds

A Study on the exposure dose for the computed tomography (컴퓨터 단층촬영시 환자피폭선량에 관한 연구)

  • Kim, Moon-Chan;Lim, Jong-Suck;Park, Hyung-Ro;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.21-27
    • /
    • 2004
  • This study was conducted to estimate absorbed radiation doses associated with CT examinations. We compared CT dose index between single detector CT and multi detector CT. To establish radiation dose criteria in CT examination in Korea, we measured radiation dose for CT examinations in Seoul and kyungki-do. The results obtained were as follows ; 1. Averaged CTDIW value per 100 mAs was $13.5{\pm}3.2\;mGy$, and ranged from 8.1 mGy to 19.1 mGy in head phantom, was $7.1{\pm}2.0\;mGy$, and ranged from 3.7 mGy to 10.9 mGy in body phantom. 2. CTDIW was 3.2 mGy(1.26 times) larger in multi detector CT than single detector CT in head phantom, and 2.1 mGy(1.34 times) larger in body phantom. 3. The dose was the highest in 4 channel multi detector CT, and followed 8 channel multi detector CT, 16 channel multi detector CT and single detector CT in head phantom. And the dose was the highest in 4 channel and 8 channel multi detector CT, and followed 16 channel multi detector CT and single detector CT in body phantom.

  • PDF

Recurrent Lesions in the Malignant Head and Neck Tumors; CT and MRI Evaluation (두경부 악성종양의 치료 후 재발 병변 ; CT와 MRI소견)

  • Kim Hyung-Soo;Lee Nam-Joon;Choi Jong-Ouck
    • Korean Journal of Head & Neck Oncology
    • /
    • v.15 no.2
    • /
    • pp.166-171
    • /
    • 1999
  • Background and Objectives: The aim of our study was to describe the appearance of recurrent and residual lesions in the head and neck tumors, and to evaluate the usefullness of CT and MRI. Materials and Methods: CT(n=42) and MRI(n=4) of 44 patients with recurrent head and neck tumors were reviewed retrospectively. Primary tumor sites were larynx/hypopharynx in 15, oral cavity/floor of mouth in 13, base of tongue/tonsil in 5, nasopharynx in 4, palate in 2, and others in 5 patients. Therapeutic modalities included sugery and radiotherapy in 23, radiotherapy in 11, surgery in 5, chemotherapy and radiotherapy in 4, and chemotherapy in 1 patient. Results: The patterns of tumor recurrence were nodal recurrence(n=17), primary tumor bed recurrence combined with nodal recurrence(n=12), primary tumor bed recurrence(n=10) and residual primary tumors(n=5). The most common appearance of residual/recurrent primary tumor on CT was focal or diffuse heterogenous mass with or without surrounding fat or muscle infiltration(25/27). On MRI, the recurrent lesions showed intermediate signal intensity on T1 weighted image and high signal intensity on T2 weighted image with heterogenous enhancement in the most cases(n=3). 38 out of 44 nodal recurrences(86%) which had been pathologically or clinically proved were more than 1 cm in diameter or contained central low density on CT scan. Conclusion: Although CT and MRI findings of recurrent and residual tumors of the head and neck were nonspecific, in the majority the lesions manifested as a mass at primary tumor bed and/or nodal disease including contralateral side of the neck. And CT and MRI are valuable for revealing above lesions.

  • PDF

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF

Assessment of the Eye Lens Dose Reduction by Bismuth Shields in Rando Phantom Undergoing CT of the Head (Head CT 검사 시 안구 차폐용 Bismuth사용에 의한 수정체 선량 감소에 대한 평가)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, In-Ja;Chang, Sang-Gyu;Chung, Jung-Pyo;Lee, Hyun;Kim, Jang-Seob;Shin, Dong-Cheol;Choi, Jong-Hak;Lee, Ki-Sung;Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.171-175
    • /
    • 2008
  • The aim of this study is to assess the dose reduction of eye lens and availability of bismuth garments resulting from the use of radioprotective bismuth garments to shield the eyes of patients undergoing head CT. Rando phantom and TLDs were used to determine the amount of dose reduction by bismuth shielding of the eye in the following simulated CT scans : (a) scanning of the head including orbits, (b) scanning of the whole head, and (c) $20^{\circ}$ angled scanning of the head excluding orbits. The average dose reduction of eye lens was 43.2%, 36.0% and 1.4% for the three CT scans listed above. Significant reduction in the eye lens dose was achieved by using superficial orbital bismuth shielding during head CT scans. However, bismuth shields should not be used for the patients when their eyes are excluded from the primarily exposed region.

  • PDF

The Utility of $^{18}F$-FDG PET/CT for Following Up Head and Neck Cancer (두경부암 환자의 추적관찰에서 $^{18}F$-FDG PET/CT의 유용성)

  • Chung, Eun-Jae;Baek, Seung-Kuk;Woo, Jeong-Soo;Kwon, Soon-Young;Jung, Kwang-Yoon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.2
    • /
    • pp.178-182
    • /
    • 2010
  • 서 론 : 두경부암의 예후에 가장 중요한 인자는 진단시 병기와 치료 후 재발의 유무이다. 따라서, 재발 병변을 조기에 발견하는 것이 매우 중요하다. 본 연구에서는 두경부암 환자의 추적 관찰에서 $^{18}F$-FDG PET/CT의 유용성에 대해 알아보고자 하였다. 대상 및 방법 : 2004년 4월부터 2008년 8월까지 고려대 안암병원에서 두경부암으로 치료를 완료한 후 추적관찰이 가능하였던 88 예의 환자를 대상으로 하였다. 환자는 본원의 두경부암 추적관찰 양식에 따라 술 후 6, 12개월째 $^{18}F$-FDG PET/CT를 시행하였으며, 원발부위 및 경부 재발, 원격전이와 중복암의 진단에 있어 $^{18}F$-FDG PET/CT의 민감도, 특이도, 양성예측율, 음성예측율을 평가하였고, 기존의 추적관찰 방법과 이를 비교하였다. 결 과 : 원발부위 재발의 진단에 있어 민감도, 특이도, 양성예측율, 음성예측율은 각각 95%, 97%, 90%, 98% 였다. 경부전이 재발의 진단에 있어서는 각각 94%, 98%, 83%, 99%였으며, 원격전이 및 이차암 진단에 있어서는 94%, 100%, 100%, 99%였다. 원발부위 재발은 고식적인 진단 방법, 원격전이와 이차암은 $^{18}F$-FDG PET/CT가 진단에 의미있게 유리하였다. 결 론 : $^{18}F$-FDG PET/CT는 두경부암의 추적관찰 과정에서 재발 여부를 판정하는데 있어 매우 유용하며, 특히 원격전이 및 이차암의 발견에 있어 유용하다. 그러나, 위양성 및 위음성의 가능성으로 고식적인 진단 방법과 병행해야 진단의 효과를 높힐 것으로 생각된다.

Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact (Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가)

  • Lee, Chung-Hwan;Yun, In-Ha;Hong, Dong-Gi;Back, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.85-95
    • /
    • 2010
  • Purpose: The degradation of an image quality and error of the beam dose calculation can be caused because the metal artifact is generated during the CT simulation of head and neck patient. The usability of the gantry tilt scan for reducing the metal artifact tries to be appraised. Materials and Methods: The inferior $20^{\circ}$ gantry tilt scan was made in order to reduce the metal artifact and $0^{\circ}$ reconstruction image was acquired. The AAPM CT performance Phantom was used in order to compare the CT number of the reconstructed image and Original image. the difference of volume was compared by using the acrylic phantom. The homogeneity of the CT number was evaluated the Intensity volume Histogram (IVH) as in order to evaluate an influence by the metal artifact. A dose was evaluated as the Dose Volume Histogram (DVH). Results: in the comparison of the CT number and volume, the difference showed up less than 0.5%. As to the comparison of IVH, in the gantry tilt scan, influence by an artifact was reduced and the homogeneity of the CT number was improved. The comparison of DVH result reduced the mean dose error of the both sides parotid 0.2~6%. Conclusion: In the Head & Neck radiation therapy, It is difficult and to distinguish tumor and normal tissue and the error of dose is generated by the metal artifact. The delineation of the exact organization was possible if the Gantry tilt scan was used. The CT number homogeneity was improved and the error of dose could be reduced. The Gantry tilt scan confirmed in the Head & Neck radiation therapy to be very useful in the exact radiation therapy.

  • PDF

Is Routine Repeated Head CT Necessary for All Pediatric Traumatic Brain Injury?

  • Kim, Won-Hyung;Lim, Dong-Jun;Kim, Se-Hoon;Ha, Sung-Kon;Choi, Jong-Il;Kim, Sang-Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.125-130
    • /
    • 2015
  • Objective : Repeated computed tomography (CT) follow up for traumatic brain injury (TBI) patients is often performed. But there is debate the indication for repeated CT scans, especially in pediatric patients. Purpose of our study is to find risk factors of progression on repeated CT and delayed surgical intervention based on the repeated head CT. Methods : Between March, 2007 and December, 2013, 269 pediatric patients (age 0-18 years) had admitted to our hospital for head trauma. Patients were classified into 8 subgroups according to mechanisms of injury. Types, amount of hemorrhage and amount changes on repeated CT were analyzed as well as initial Glasgow Coma Scale (GCS) scores. Results : Within our cohort of 269 patients, 174 patients received repeat CT. There were progression in the amount of hemorrhage in 48 (27.6%) patients. Among various hemorrhage types, epidural hemorrhage (EDH) more than 10 cc measured in initial CT was found to be at risk of delayed surgical intervention significantly after routine repeated CT with or without neurological deterioration than other types of hemorrhage. Based on initial GCS, severe head trauma group (GCS 3-8) was at risk of delayed surgical intervention after routine repeated CT without change of clinical neurologic status. Conclusion : We suggest that the patients with EDH more than 10 cc or GCS below 9 should receive repeated head CT even though absence of significant clinical deterioration.

A Nationwide Study on the Epidemiology of Head Trauma and the Utilization of Computed Tomography in Korea (건강보험심사평가원 환자표본자료를 이용한 국내 두부손상의 역학 및 뇌 CT 시행 분석)

  • Park, So Young;Jung, Jae Yun;Kwak, Young Ho;Kim, Do Kyun;Suh, Dong Bum
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.152-158
    • /
    • 2012
  • Purpose: To understand the epidemiology of head trauma and the utilization of brain CT in Korea, we analyzed a national sampling data set, the National Patient Sample obtained from the Health Insurance Review and Assessment Service. Methods: We retrospectively collected and analyzed demographic and clinical data on enrolled patients from the National Patient Sample based on medical claims data for 2009. The data included patient's age, sex, treatment date, diagnosis codes, procedure codes related with CT, holiday or night consultation fee, and fee for emergency management services. Results: In 2009, the estimated population with head trauma was 819,059(1.8%), and the rate of brain CT utilization was 22.4%. Children ages 5 to 15 were the most commonly injured group(22.8%), but had the lowest brain CT utilization(16.5%). The mean age of the estimated population with head trauma was $34.9{\pm}0.5years$ old, and male patients accounted for 60.5% of that population. Intracranial injury was found in 8.6% of all head traumas, and the rate of intracranial injury in children was lower than it was in adults(4.1% vs. 10.9%, p<0.001). Twenty- three percent of patients with head trauma visited the emergency department (ED). More patients with head trauma visited medical facilities in the daytime on weekdays(66.5% vs. 33.5%, p<0.001), but head CT was performed more frequently at night or on weekends/holidays(16.1% vs. 34.7%, p<0.001) There is low incidence of head trauma in the winter in children (p<0.001). In the multivariate logistic regression analysis, patients who were adults, female, or ED visitors were more likely to undergo brain CT (odds ratio (OR): 1.65, 95% confidence interval (CI): 1.47-1.84; OR: 1.40, 95% CI: 1.27-1.54; OR: 7.80, 95% CI: 6.91-8.80, respectively). Conclusion: In this study, we analyzed the national epidemiologic trend for head trauma, and the pattern of utilization of brain CT.