• Title/Summary/Keyword: Heat Characteristic

Search Result 1,233, Processing Time 0.031 seconds

Pin Fin Optimization Based on the Ratio of Heat Loss to the Maximum Heat Loss (최대 열손실에 대한 열손실 비에 기준한 Pin 핀의 최적화)

  • Kang, Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.817-823
    • /
    • 2008
  • A pin fin with variable fin base thickness is optimized based on the ratio of heat loss to the maximum heat loss using a two-dimensional analytic method. The temperature profile along the normalized radius position in the fin is presented. For fixed fin outer radius, the optimum heat loss, fin length and efficiency as a function of fin base thickness, outer radius, convection characteristic numbers ratio and ambient convection characteristic number are presented. One of the results shows that the effect of fin outer radius and ambient convection characteristic number on the optimum fin length is remarkable.

An Experimental Study on Cooling Characteristic according to Fin Array of Aluminum Heat Sink (히트싱크의 핀 배열에 따른 냉각특성에 관한 실험적 연구)

  • Yoon, Sung-Un;Kim, Jae-Yeol;Gao, Jia-Chen
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.138-143
    • /
    • 2018
  • In general, the operating temperature of electronic equipment is closely related to product life and reliability, and it is recognized that effectively cooling the parts is an important problem. In this paper, an experimental study on the cooling characteristic according to the pin array of the heat sink is conducted. The experiment on the heat sink was based on the natural convection and temperature distribution changes. The experimental results indicate that the pin array of the heat sink has an effect on the thermoelectric module's cooling characteristic.

OPTIMZATION OF A PIN FIN BASED ON THE INCREASING RATE OF HEAT LOSS

  • Kang, Hyung-Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.12 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • A pin fin is optimized based on the increasing rate of heat loss by using a two-dimensional analytic method. The optimum heat loss, corresponding optimum thermal resistance and fin length are presented as a function of the fin base thickness, convection characteristic numbers ratio, fin outer radius and ambient convection characteristic number. One of the results shows that both the optimum heat loss and fin length decrease linearly whereas the optimum thermal resistance increases very slightly with increase of the fin base thickness.

  • PDF

An Experimental Study on Applying Heat Pump System to Facility Horticulture House (히트펌프 시스템의 시설원예 적용에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

Optimal Operation Model of Heat Trade based District Heating and Cooling System Considering Start-up Characteristic of Combined Cycle Generation (가스터빈 복합발전의 기동특성을 고려한 열거래 기반 지역 냉난방 시스템의 최적 운영 모델)

  • Kim, Jong-Woo;Lee, Ji-Hye;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1610-1616
    • /
    • 2013
  • Recently, district heating and cooling (DHC) systems based on combined cycle generation (CCG) providers are increasing in Korea. Since characteristics of combined heat and power (CHP) generators and heat demands of providers, heat trading between DHC providers based on the economic viewpoint is required; the heat trading has been doing. In this paper, a mathematical model for optimal operation based on heat trading between DHC providers is proposed. Especially, start-up characteristic of CCG is included. The operation model is established by mixed integer linear programming (MILP).

Analysis of a Cylindrical Pin Fin with Variable Diameter (직경이 변하는 원통형 Pin 핀의 해석)

  • Kang, Hyung-Suk;Kim, Jong-Ug
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.71-75
    • /
    • 2007
  • A cylindrical pin fin with variable diameter is analyzed by using the one dimensional analytical method. Heat loss and fin efficiency are presented as a function of the fin diameter, length and convection characteristic numbers ratio. The relationship between the fin diameter and convection characteristic number over the fin for the same amount of heat loss is shown. One of the results indicates the fin efficiency increases as the fin diameter increases while that decreases as the fin length increases.

  • PDF

OPTIMUM PERFORMANCE AND DESIGN OF A RECTANGULAR FIN

  • Kang, H.S.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.705-711
    • /
    • 2007
  • A rectangular fin with a fluid in the inside wall is analyzed and optimized using a two-dimensional analytical method. The influence of the fluid convection characteristic number in the inside wall and the fin base thickness on the fin base temperature is listed. For the fixed fin volumes, the maximum heat loss and the corresponding optimum fin effectiveness and dimensions as a function of the fin base thickness, convection characteristic numbers ratio, convection characteristic number over the fin, fluid convection characteristic number in the inside wall, and the fin volume are represented. One of the results shows that both the optimum heat loss and the corresponding fin effectiveness increase as the fin base thickness decreases.

A Study on the radiant Heat Characteristic According to Type and Array of LED Lighting Heatsink (LED 조명등 히트싱크 형상과 배열에 따른 방열특성에 관한 연구)

  • Jang, Hyun;Suh, Jeong Se;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.3
    • /
    • pp.54-60
    • /
    • 2013
  • Numerical analysis of the radiant heat characteristic around heatsink according to arrangement and shape of fin on 60W-LED lamp is conducted in this study. In the case of top blow blowing from upper side on LED lamp, there is just little difference in cooling characteristics according to the height of fin. On the other hand, the fin arranged side by side has the advantage of heat transfer enhancement by comparing with zig-zag type because it leads to more loss of flow. In case of making fin round to increase the amount of heat transfer, designing arrangement with the minimized loss of flow has the advantage of characteristic.

Analysis of a Convective, Radiating Rectangular Fin (대류, 복사 사각 핀의 해석)

  • Kang, Hyung-Suk;Kim, Jong-Ug
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.29-34
    • /
    • 2006
  • A convective, radiating rectangular fin is analysed by using the one dimensional analytic method. Instead of constant fin base temperature, heat conduction from the inner wall to the fin base is considered as the fin base boundary condition. Radiation heat transfer is approximately linearized. For different fin tip length, temperature profile along the normalized fin position is shown. The fin tip length for 98% of the maximum heat loss with the variations of fin base length and radiation characteristic number is listed. The maximum heat loss is presented as a function of the fin base length, radiation characteristic number and Biot number.

  • PDF

A Characteristic Heating-Energy Expend of Insulation Block System for Korea Type Passive House (한국형 패시브하우스를 위한 단열블럭시스템의 난방에너지소비 특성)

  • Kang, Jae-Sik;Choi, Gyoung-Seok;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.603-607
    • /
    • 2009
  • About a Structure is performance external insulation is fundamantal performance for enrgy-saving. these day, most of residential structures have constructed by internal insulation method structure. The method structure internal insulation have construction and economical efficiency, but on the other hand, be generated heat loss by heat bridge especially, be generated loss heat-energy logical consequence in structure ondol. The external insulation structure method has a mert able to minimum to loss heat about heat-bridge. But the external insulation technique is unsatisfactory statues within the know-how and method of construction and materials compared with developed countries. The recently, the requirement of market related to the external insulation technique is resulted by the energy efficiency system, but it can lead to the lack of alternative technique In study on the korea type passive house building design for insulation block method of wall system has to experimental characteristic heat-energy of practice building. In result field-experimental, the heat-bridge appeared to characteristic spent heat-energy of blow 2L class and have a suffience performance it.

  • PDF