• Title/Summary/Keyword: Heat balance model

Search Result 184, Processing Time 0.022 seconds

Estimation of Expected Temperature Using Heat Balance Model and Observation Data

  • Kim, Eun-Byul;Park, Jong-Kil;Jung, Woo-Sik
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.214-221
    • /
    • 2015
  • This study considers mean skin temperature to calculate expected temperature using the new heat balance model because the skin temperature is the most important element affecting the heat balance outdoors. For this, we measured the skin temperature in high temperature condition of Korea and applied it to calculate the expected temperature. The calculated expected temperature is compared with the result calculated using previous models which use the estimated mean skin temperature by considering metabolic rate only. Results show that the expected temperatures are higher when measured mean skin temperature is applied to the model, compared to the expected temperature calculated by applying mean skin temperature data calculated using metabolic rate like previous models. The observed mean skin temperature was more suitable for outside conditions and expected temperature is underestimated when mean skin temperature calculated by the equation using metabolic rate is used. The model proposed in this study has a few limitations yet, but it can be applied in various ways to facilitate practical responses to extreme heat.

Lifter Design for Enhanced Heat Transfer in Rotating Counter-Current Flow Reactor and Application to One Dimensional Heat Balance Model (회전식 대향류 반응기 내 열전달 증진을 위한 리프터 설계와 1차원 열평형 모델로의 적용)

  • Lee, Hookyung;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.51-54
    • /
    • 2013
  • Rotary kiln reactors are frequently equipped with an axial burner with which solid burden material is directly heated. Lifters are commonly used along the length of the system to lift particulate solids and increase the heat transfer between the solid bed and the combustion gas. The material cascading from the lifters undergoes drying and reacting through direct contact with the gas stream. In this study, volume distribution of materials held within lifters was modeled according to the different lifter configuration and appropriate configuration was used for the design purpose. This was applied to the one-dimensional heat balance model of a counter-current flow reactor, which contributes to the increase of the effective contact surface, and thereby enhances the heat transfer.

  • PDF

Simplified 1-Dimensional Model of Gas-Solid Reactor : Adapting to Coal Reduction Rotary Kiln (1차원 기체-고체 반응기 모델의 로터리킬른 환원로 적용)

  • Hahn, Taekjin;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.75-78
    • /
    • 2012
  • Rotary kiln furnace is one of the most widely used reactors in industrial field. In this paper, 0-dimensional heat and mass balance for direct coal flame rotary kiln was performed preferentially, then a simplified 1-dimensional model was developed based on 0-dimensional analysis data to proceed additional thermal analysis. Compared the results with the currently operating rotary kiln data to validate 1-dimensional model. Through this procedure, it can help to derive fundamental idea for design and operation of rotary kiln.

  • PDF

Calculation of Mass-Heat Balance on the Iodine Crystallizer for SI Thermochemical Hydrogen Production Process (SI 열화학 수소 생산 공정 요오드 결정화기 열-물질 수지 계산)

  • Lee, Pyoung Jong;Park, Byung Heung
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • SI thermochemical hydrogen production process achieves water splitting into hydrogen and oxygen through three chemical reactions. The process is comprised of three sections and one of them is HI decomposition into $H_2$ and $I_2$ called as Section III. The production of $H_2$ included processes involving EED for concentrating a product stream from Section I. Additionally an $I_2$ crystallization would be considered to reduce burden on EED by removing certain amount of $I_2$ out of a process stream prior to EED. In this study, the current thermodynamic model of SI process was briefly described and the calculation results of the applied Electrolytes NRTL model for phase equilibrium calculations was illustrated for ternary systems of Section III. We calculated temperature and heat duty of an $I_2$ crystallizer and heat duty of heaters using UVa model and heat balance equation of simulation tool. The results were expected to be used as operation information in optimizing HI decomposition process and setting up material balance throughout SI process.

Intake Valve Temperature Effect on the Mixture Preparation in a SI Engine During Warm-up

  • 신영기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.51-66
    • /
    • 1997
  • A heat transfer model of the intake valve in a spark ignition engine is presented, which is calibrated with a number of the valve temperature profiles measured during engine warm-up for the gaseous fuel(propane). The valve is divided into four identical elements for which the assumption of lumped thermal mass is applied. The calibration is made so that the difference between the measued and simulated valve temperatures becomes minimal. Then the model is applied to the cases of the liquid fuel(indolene) to estimate the amount of the liquid fuel vaporized from the intake valve by assuming that fuel evaporation accounts for the deficit of the heat balance budget. The results of the model show quantitative contribution of each heat transfer source to the heat balance. The behavior of the calculated mass fraction of the fuel vaporized from the intake valve explains how the liquid fuel evaporate during engine warm-up. The mass fraction at warmed-up condition is closely related with the fraction directly targeted on the valve back by the fuel spray geometry.

  • PDF

A Theoretical Model of Critical Heat Flux in Flow Boiling at Low Qualities

  • Kim, Ho-Young;Kwon, Hyuk-Sung;Hwang, Dae-Hyun;Kim, Yongchan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.921-930
    • /
    • 2001
  • A new theoretical critical heat flux (CHF) model was developed for the forced convective flow boiling at high pressure, high mass velocity, and low quality. The present model for an intermittent vapor blanket was basically derived from the sublayer dryout theory without including any empirical constant. The vapor blanket velocity was estimated by an axial force balance, and the thickness of vapor blanket was determined by a radial force balance for the Marangoni force and lift force. Based on the comparison of the predicted CHF with the experimental data taken from previous studies, the present CHF model showed satisfactory results with reasonable accuracy.

  • PDF

Theoretical Study on Snow Melting Process on Porous Pavement System by using Heat and Mass Transfer (열전달 및 물질전달을 이용한 공극 발열도로에서의 융설 해석에 대한 이론적 연구)

  • Yun, Taeyoung
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.1-10
    • /
    • 2015
  • PURPOSES : A finite difference model considering snow melting process on porous asphalt pavement was derived on the basis of heat transfer and mass transfer theories. The derived model can be applied to predict the region where black-ice develops, as well as to predict temperature profile of pavement systems where a de-icing system is installed. In addition, the model can be used to determined the minimum energy required to melt the ice formed on the pavement. METHODS : The snow on the porous asphalt pavement, whose porosity must be considered in thermal analysis, is divided into several layers such as dry snow layer, saturated snow layer, water+pavement surface, pavement surface, and sublayer. The mass balance and heat balance equations are derived to describe conductive, convective, radiative, and latent transfer of heat and mass in each layer. The finite differential method is used to implement the derived equations, boundary conditions, and the testing method to determine the thermal properties are suggested for each layer. RESULTS: The finite differential equations that describe the icing and deicing on pavements are derived, and we have presented them in our work. The framework to develop a temperature-forecasting model is successfully created. CONCLUSIONS : We conclude by successfully creating framework for the finite difference model based on the heat and mass transfer theories. To complete implementation, laboratory tests required to be performed.

The Effect of Building Morphology on Sea Breeze Penetration over the Kanto Plain - Analysis of Mean Kinetic Energy Balance of Moving Control Volume along Sea Breeze -

  • Sato, Taiki;Ooka, Ryozo;Murakami, Shuzo
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.73-80
    • /
    • 2012
  • In order to use sea breezes to counter the heat island phenomena, i.e. to promote urban ventilation, it is necessary to clarify the effect of building morphology and height on large-scale wind fields. In this study, the sea breeze in the vicinity of the Kanto Plain in Japan is simulated using a mesoscale meteorological model incorporating an urban canopy model, and the inland penetration of sea breezes is accurately reproduced. Additionally, a mean kinetic energy balance within a domain (Control Volume; CV) moving along the sea breeze is analysed. From the results, it is clarified that the sea breeze is interrupted by the resistance and turbulence caused by buildings at the centre of Tokyo. The interruption effect is increased in accordance with the height of these buildings. On the other hand, adverse pressure gradients interrupt in the internal region.

New approaches of Indoor Environmental Control for Energy Saving-Adaptive Model (에너지절감을 도모하는 실내 온열환경 제어논리-Adaptive Model)

  • Song, Doo-Sam;Kato, Shinsuke
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.838-846
    • /
    • 2006
  • The purpose of this study to develop the air-conditioning system that adopts adaptive model as an indoor climate control logic for energy saving. The adaptive model using the ability of human thermal adaptation could be expected to alleviate the indoor set-point temperature compared with the past heat-balance model. Especially, in case of hybrid air-conditioning system coupled with natural ventilation and heating/cooling system, the adaptive model can be describe the thermal comfort of inhabitant who stay at hybrid system controlled buildings with accuracy. In this paper, the concept of adaptive model will be described and the results of a continuous measurement on the actual thermal experiences and behaviors of thermal adaptation for office worker will be reported.

  • PDF

Development of a Ventilation Model for Mushroom House Using Adiabatic Panel

  • Kim Kee Sung;Han Jin Hee;Kim Moon Ki;Nam Sang Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.7
    • /
    • pp.35-44
    • /
    • 2004
  • In this study, a ventilation model was developed to determine a ventilation rate for the balance of heat, moisture and $CO_{2}$ in a mushroom house. Internal and external temperature, relative humidity and $CO_{2}$ concentration were measured and used to validate the ventilation model. The effects of various environmental factors on physiological responses of mushroom were also investigated. The verified model was simulated under the observed ventilation rates with a difference of$ 0.001{\~}0.065\;m^{3}{\cdot}S^{-1}$ (relative error of $0.3{\~}18.9\%$) when external temperature varied 22.5 to $24.8^{circ}C$ and average ventilation rates was $0.35m^{3}{\cdot}S^{-1}$. The optimal conditions for mushroom growth (internal temperature $22 ^{circ}C$, relative humidity $80\%$, $CO_{2}$ concentration 1,000 ppm) were used for the model application with external temperature, relative humidity and $CO_{2}$ concentration of $27.5{\~}33.5^{circ}C$, $60\%$, and 355 ppm, respectively. Thermal balance was a important factor for an optimum ventilation up to the external temperature of $32^{circ}C$, while $CO_{2}$ concentration balance was more important over $32^{circ}C$. This suggests that humidification for moisture balance is required to maintain temperature and $CO_{2}$ concentration at an optimal level by ventilation in a mushroom house.