• Title/Summary/Keyword: Heat of fusion

Search Result 434, Processing Time 0.027 seconds

Accuracy Improvement for Measurement of Heat of Fusion by T-history Method (T-history법에 의한 잠열량 측정 정확도의 향상)

  • 박창현;백종현;강채동;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.652-660
    • /
    • 2003
  • T-history method, measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and no requirements in sampling process. However, a degree of supercooling used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion in the original method, which has been improved in order to predict better results by us. In the present study, the modified method was applied to a variety of PCM such as paraffin and lauric acid having very small or no supercooling with a satisfactory precision. Also the selection of inflection point and temperature measurement position was fumed out not to affect the accuracy of heat-of-fusion significantly. As a result, the method can provide an appropriate means to assess a new developed PCM by cycle test even if a very accurate value cannot be obtained.

Improvement of the T-history Method to Measure Heat of Fusion for Phase Change Materials

  • Hong, Hi-Ki;Park, Chang-Hyun;Choi, Ju-Hwan;Peek, Jong-Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.1
    • /
    • pp.32-39
    • /
    • 2003
  • Though conventional calorimetry methods such as differential scanning calorimetry and differential thermal analysis are used generally in measuring heat of fusion, T-history method has advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermophyical properties of in-homogeneous phase change materials in sealed tubes. However, the degree of supercooling used in selecting a range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

Consideration on the T-history Method for Measuring Heat of Fusion of Phase Change Materials (PCM의 잠열측정을 위한 T-history법에 대한 고찰)

  • 박창현;최주환;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1223-1229
    • /
    • 2001
  • Though conventional calorimetry methods such as differential scanning calorimetry (DSC) and differential thermal analysis (DTA) are used generally in measuring heat of fusion, T-history method has the advantages of a simple experimental apparatus and no requirements of sampling process, which is particularly useful for measuring thermal properties of inhomogeneous phase change materials (PCMs) in sealed tubes. However, random criteria (a degree of supercooling) used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion. In the present study, it was shown that a 40% discrepancy exists between the original T-history and the present methods when analyzing the same experimental data. As a result, a reasonable modification to the original T-history method is proposed.

  • PDF

Effects of Intermediate Heat Treatment on the Corrosion and Mechanical Properties of Zr Alloy Strip Incorporating Nb (니오븀이 첨가된 Zr 합금 스트립의 부식 및 기계적 특성에 대한 중간열처리 영향)

  • Lee, Myung Ho;Jung, Yang Il;Choi, Byoung Kwon;Park, Sang Yoon;Kim, Hyun Gil;Park, Jeong Yong;Jeong, Yong Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.8
    • /
    • pp.482-487
    • /
    • 2009
  • In order to investigate the effects of intermediate heat treatment between cold rolling passes on the hardness and corrosion properties of a Zr alloy incorporating Nb (Zr-1.49Nb-0.38Sn-0.20Fe-0.11Cr) strip, three different intermediate heat treatment processes ($580^{\circ}C{\times}4hrs$, $600^{\circ}C{\times}2hrs$ and $620^{\circ}{\times}1hrs$) were designed based on a recrystallization map and an accumulated annealing parameter. Test samples from the different processes were investigated by a hardness test, corrosion test, and microstructure analysis and appropriate heat-treatment conditions were thereupon proposed. The sample subjected to an intermediate heat treatment of $580^{\circ}C{\times}4hrs$ was harder than that undergoing $600^{\circ}C{\times}2hrs$ and $620^{\circ}C{\times}1hr$ while the corrosion resistance of the sample that received an intermediate heat treatment of $580^{\circ}C{\times}4hrs$ was superior to that of the other specimens. Considering the trade-off of hardness and corrosion resistance, an intermediate heat treatment process of $600^{\circ}C{\times}2hrs$ is proposed to improve the manufacturing process of the alloy strip.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube (밀폐튜브 내 저온 PCM의 잠열측정법)

  • 류경용;박창현;백종현;홍회기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

Changes of Prosapogenin Components in Tienchi Seng (Panax notoginseng) by Ultrasonic Thermal Fusion Process

  • Lee, Jae Bum;Yang, Byung Wook;Kim, Do Hyeong;Jin, Dezhong;Ko, Sung Kwon
    • Natural Product Sciences
    • /
    • v.27 no.1
    • /
    • pp.10-17
    • /
    • 2021
  • The purpose of this study is to develop a new method of producing tienchi seng (notoginseng, Panax notoginseng) extracts featuring high concentrations of the ginsenoside Rg3, Rg5, and Rg6, special components of Korean red ginseng. The chemical transformation from ginseng saponin glycosides to prosapogenin was analyzed by HPLC. Tienchi seng was heat-processed at 100℃ and the optimum conditions were identified. The highest concentrations of total saponin (29.723%) and the ginsenoside Rg3 (1.769%), Rg5 (5.979%), and Rg6 (13.473%) were produced at 48 hours. Also, when tienchi seng was subjected to the ultrasonic thermal fusion (100℃) process, the concentrations of total saponin (30.578%), ginsenoside Rg3 (2.392%), Rg5 (6.614%), and Rg6 (13.017%) were highest at 36 hours. On the other hand, the 2-hour heat-processed extract and 2-hour ultrasonic thermal fusion-processed extract did not contain ginsenoside Rg3, Rg5, and Rg6. The ultrasonic thermal fusion process had an extraction yield that was approximately 1.26 times greater than that of the heat process. These results indicate that the highly functional tienchi seng extracts created through the ultrasonic thermal fusion process are more industrially useful than those produced using the heat process.

Effects of Final Heat Treatment on Corrosion and Mechanical Properties of Zr Alloy Strip Incorporating Nb (니오븀이 첨가된 Zr 합금 스트립의 부식 및 기계적 특성에 대한 최종열처리 영향)

  • Lee, Myung Ho;Jung, Yang Il;Choi, Byoung Kwon;Park, Sang Yoon;Kim, Hyun Gil;Park, Jeong Yong;Jeong, Yong Hwan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.8
    • /
    • pp.474-481
    • /
    • 2009
  • The effects of final heat treatment on the mechanical and corrosion properties of a Zr alloy strip incorporating Nb were investigated. The chemical composition of the strip was Zr-1.49Nb-0.38Sn-0.20Fe-0.11Cr, and strip specimens were subjected to final heat treatment in a temperature range of $580{\sim}700^{\circ}C$. Tensile tests at room temperature and $316^{\circ}C$, along with corrosion tests in a simulated PWR loop and a 70 ppm LiOH solution environment at $360^{\circ}C$, were performed on the specimens. The mechanical properties of the strip were saturated when the specimens received final heat treatment at an elevated temperature of more than $640^{\circ}C$. However, the corrosion resistance of the strip in the simulated PWR loop and in the 70 ppm LiOH solution environment was improved with a decrease of the final annealing temperature. It is recommended that the alloy strip be finally heat-treated at a temperature of less than $620^{\circ}C$ for longer than 10 minutes in order to obtain fully recrystallized microstructures, and thereby attain enlarged tensile elongation, and to prevent the precipitation of ${\beta}-Zr$, which is known to deteriorate the corrosion resistance.

An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs (PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구)

  • Sung, Dae-Hoon;Kim, Min-Jun;Kim, Joung-Ha;Yun, Jae-Ho;Kim, Woo-Seung;Peck, Jong-Hyeon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

Study on the Frition Welding Characteristics of Oxygen Free High Conductivity Copper (무산소동의 마찰 용접 특성에 관한 연구)

  • 정호신;소전강
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.10-15
    • /
    • 1997
  • Copper and its alloy had been used widely because of its pronouncing characteristics on their high thermal and electrical conductivity. Various fusion welding methods, such as SMAW, SAW, GTAW, GMAW, Electroslag welding amd so on are applied to weld copper and its alloy. But fusion welding of copper has so many welding problems. THe most serious problems were poor penetration amd high thermal contration stress due to its high thermal conductivity and porosity could be formed by rapid cooling rate of fusion welding. In order to avoid such fusion welding problems, preheating, peering and heat treatment must be applied to obtain sound weld joint of copper. But preheating induce another welding problem such as grain coarsening of weld heat affected zone. This grain coarsening reduces ductility and strength of weld joint. In this view of point, friction welding of copper is triedm to obtain sound weld joint of copper by reducing metallurgical problems. This study introduced new concept of heat input for evaluating the friction weldability of copper. As a result, weldability of copper could be evaluated by this new concept of heat input.

  • PDF