• Title/Summary/Keyword: Hercules sizing

Search Result 4, Processing Time 0.018 seconds

Automatic Color Recognition System for Stockigt Sizing Test (II) - Application of the automatic recognition principle of red coloration for developing the novel automatic system - (스테키히트 시험용 자동발색인지 시스템 개발을 위한 기초 연구(II) -자동 발색 인지 원리를 적용한 발색 자동인지시스템-)

  • Kim, Jae-Ok;Kim, Chul-Hwan;Park, Chong-Yawl;Kwon, Oh-Chul
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.1 s.109
    • /
    • pp.73-81
    • /
    • 2005
  • Stockigt sizing test, which is readily affected by individual tester's bias as well as testing conditions in recognizing red coloration, had to be modified to improve its reliability and reproducibility. The novel testing system with the automatic recognizing program of red coloration was developed with the auxiliary equipments including an automatic liquid dispenser and a specimen shifter. The analysis program used a hue value of a droplet image in recognizing a point of time on red coloration instead of RGB values that are not similar to human perception of color. Hue was more sensitive in recognizing the red coloration of a droplet than the other two factors, Saturation and Value. During the test, the program records the time consumed up to a specific hue value of a droplet on a specimen. Differently from the conventional test, the automatic test could obtain a reliable and reproducible sizing degree with a minor error. Furthermore, the Stockigt sizing degree measured by the automatic system showed great correlations with contact angle and Hercules sizing degree. It means that such great correlations will contribute to the development of an integrated measuring system capable of predicting contact angle, surface tension, surface energy and Hercules sizing degree of paper and paperboards through the Stbckigt sizing test. It was meaningful to note that the automatic system for Stbckigt sizing test might be able to used to predict contact angle, Hercules and Cobb sizing degree, based upon the high correlation coefficients.

Automatic Measurement System for Sizing Test I (사이즈도 자동 측정 시스템 개발을 위한 기초연구 I)

  • Kim, Gyeong-Cheol;Kim, Cheol-Hwan;Lee, Ji-Yeong;Sheikh, Mominul Islam;Park, Hyeon-Jin;Kim, Seong-Ho;Sim, Seong-Ung;Jo, Hu-Seung
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.327-333
    • /
    • 2011
  • This study investigated the prime difference between different methods for measuring a sizing degree. Based on the results coming from the study, a new type of the automatic measuring system of a sizing degree. The system includes synchronized devices for measuring contact angle and St$\ddot{o}$ckigt sizing degree at the same time.

  • PDF

Evaluation of Reliability of Automatic System for Measuring Sizing Degree by Basis Weight Variation of Paper (종이 평량의 차이에 따른 자동 사이즈도 측정 시스템의 신뢰성 평가)

  • Lee, Ji-Young;Kim, Chul-Hwan;Lee, Ji-Young;Nam, Hye-Gyeong;Lee, Gyeong-Sun;Jo, Hu-Seung;Park, Hyung-Hun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.3
    • /
    • pp.11-19
    • /
    • 2014
  • Reliability of the novel automatic system capable of measuring both St$\ddot{o}$ckigt sizing degree and contact angle at a time was evaluated through the calculation of its repeatability and reproducibility based on TAPPI Standard Method T 1200. As the basis weight of paper specimen increased, the repeatability and reproducibility of the automatic system became more improved than those from Hercules sizing test and contact angle test designated on TAPPI Standard Method T 530 and T 558. The more improved repeatability and reproducibility implies that a single tester can obtain the similar results under similar test conditions in spite of repetitive testing using the automatic system, and likewise that multiple testers can respectively reproduce similar data without big variation from the same paper specimen using the automatic system. In conclusion, this study is greatly meaningful in having developed the world's first automatic system to measure both St$\ddot{o}$ckigt sizing degree and contact angle simultaneously with excellent repeatability and reproducibility.

Behavior of AKD in AKD-sized Paper by Heating Treatment During Ageing (AKD 사이즈 처리한 종이의 저장중 가열처리에 의한 AKD의 거동)

  • Shin, Young-Doo;Seo, Won-Sung;Cho, Nam-Seok
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.1 s.119
    • /
    • pp.16-24
    • /
    • 2007
  • This study was performed to investigate the reaction between alkylketene dimer(AKD) and cellulose molecules in AKD-sized paper sheet. AKD was added to highly beaten($80{\pm}3^{\circ}SR$) SwBKP(ca. 0.8% on pulp) in order to have much AKD retention in the paper sheet. This AKD-sized paper sheet was aged at different temperatures, $60^{\circ}C,\;80^{\circ}C,\;105^{\circ}C\;and\;125^{\circ}C$. Changes in FT-IR spectra of AKD in paper sheet during the ageing were measured. In addition, sizing degrees of the AKD-sized paper sheet pretreated for 30 sec. at $105^{\circ}C$ were measured by HST size tester during the storage at different temperature. IR spectra of AKD-sized paper sheet preheated at $105^{\circ}C$ for 30 sec. showed unchanged spectra two absorption bands at $1849cm^{-1}\;and\;1722cm^{-1}$ which refer to the typical AKD IR bands. However, these typical AKD bands were gradually reduced with increasing ageing, completely disappeared after 6 hrs. and formed new absorption band at $1706cm^{-1}$, which refers to carbonyl stretching vibration of dialkylktone. Eventually the AKD molecule was hydrolyzed to diakylketone without formation of ${\beta}$-ketoester with cellulose in paper sheet. After 6 days ageing, a little amount of ${\beta}$-ketoester bands was identified in 6 or 7 days ageing, because of the absence of water due to long-term heating. The same tendency was observed at different ageing conditions. At the practical papermaking process, AKD reacts prevailing with water, and mostly seems to be hydrolyzed to dialkylketene. Concerned to the sizing development, AKD-sized paper sheet was shown no sizing development at the initial stage of ageing at $60^{\circ}C$ after heating treatment at $105^{\circ}C$ for 30 sec., and gradually increased the sizing degree with increasing ageing, such as Hercules Sizing Tester (HST) 130 see for 12 hr, HST 300 sec. for 3 days and HST 400 sec. for 5 days. It was concluded that hydrolyzed AKD could contributed to the sizing development of the paper sheet.