• Title/Summary/Keyword: High Magnetic Field

Search Result 1,514, Processing Time 0.03 seconds

Fabrication and magnetic properties of hexagonal BaFe12O19 ferrite obtained by magnetic-field-assisted hydrothermal process

  • Zhang, Min;Dai, Jianming;Liu, Qiangchun;Li, Qiang;Zi, Zhenfa
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1426-1430
    • /
    • 2018
  • High magnetic field effects on the microstructure and magnetic properties of $BaFe_{12}O_{19}$ hexaferrites synthesized hydrothermal method have been investigated. The obtained results indicate that the lattice constant decreases gradually as the magnetic field strength increases, which may be attributed to the lattice distortion resulted from the high magnetic field. Polycrystalline $BaFe_{12}O_{19}$ samples prepared under magnetic field strength at zero and 5 T are single phase. It is found that application of external magnetic field during synthesis can induce orientated growth of the hexaferrite crystals along the easy magnetic axis. The magnetic properties can be effectively regulated by an application of high magnetic fields. It is observed that the $BaFe_{12}O_{19}$ prepared under a 5 T magnetic field exhibits a higher room-temperature saturation magnetization (66.3 emu/g) than that of the sample (43.6 emu/g) obtained without magnetic field. The results can be explained as the enhanced crystalline, improvement of $Fe^{3+}$ ions occupancy and the oriented growth induced by the external magnetic field. The growing orientation of particles gives rise to increased coercivity due to the enhancement in shape anisotropy. It is expected that an application of magnetic field during the formation of magnetic nanoparticles could be a promising technique to modify magnetic properties with excellent performance.

Formation of Charged Exciton in GaAs-AlGaAs Double-Quantum-Well Structure at High Magnetic Field (GaAs 이중 양자우물구조에서 고자기장에 유도된 대전된 엑시톤의 발생)

  • Kim, Yong Min
    • Journal of Integrative Natural Science
    • /
    • v.2 no.4
    • /
    • pp.265-269
    • /
    • 2009
  • The photoluminescence was measured in GaAs-AlGaAs double-quantum-well structure at high magnetic field. Although the phototransition characteristics displayed a free-particle transition at low magnetic field, the change of free-particle transition into bound-exciton transition was observed at high magnetic field (above 10 T). A charged exciton formation due to charge-unbalanced electron-hole was identified by using a spin-polarized photoluminescence method. An increase of exciton formation due to the localization of free-particle at magnetic field was observed according to the increase of magnetic field.

  • PDF

Magnetic separation device for paramagnetic materials operated in a low magnetic field

  • Mishima, F.;Nomura, N.;Nishijima, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.19-23
    • /
    • 2022
  • We have been developing a magnetic separation device that can be used in low magnetic fields for paramagnetic materials. Magnetic separation of paramagnetic particles with a small particle size is desired for volume reduction of contaminated soil in Fukushima or separation of iron scale from water supply system in power plants. However, the implementation of the system has been difficult due to the needed magnetic fields is high for paramagnetic materials. This is because there was a problem in installing such a magnet in the site. Therefore, we have developed a magnetic separation system that combines a selection tube and magnetic separation that can separate small sized paramagnetic particles in a low magnetic field. The selection tube is a technique for classifying the suspended particles by utilizing the phenomenon that the suspended particles come to rest when the gravity acting on the particles and the drag force are balanced when the suspension is flowed upward. In the balanced condition, they can be captured with even small magnetic forces. In this study, we calculated the particle size of paramagnetic particles trapped in a selection tube in a high gradient magnetic field. As a result, the combination of the selection tube and HGMS (High Gradient Magnetic Separation-system) can separate small sized paramagnetic particles under low magnetic field with high efficiency, and this paper shows its potential application.

Effect of Magnetic Field Annealing on Microstructure and Magnetic Properties of FeCuNbSiB Nanocrystalline Magnetic Core with High Inductance

  • Fan, Xingdu;Zhu, Fangliang;Wang, Qianqian;Jiang, Mufeng;Shen, Baolong
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.29-35
    • /
    • 2017
  • Transverse magnetic field annealing (TFA) was carried out on $Fe_{73.5}Cu_1Nb_3Si_{15.5}B_7$ nano-crystalline magnetic core with the aim at decreasing coercivity ($H_c$) while keeping high inductance ($L_s$). The magnetic field generated by direct current (DC) was applied on the magnetic core during different selected annealing stages and it was proved that the nanocrystalline magnetic core achieved lowest $H_c$ when applying transverse field during the whole annealing process (TFA1). Although the microstructure and crystallization degree of the nanocrystalline magnetic core exhibited no obvious difference after TFA1 compared to no field annealing, the TFA1 sample showed a more uniform nanostructure with a smaller mean square deviation of grain size distribution. $H_c$ of the nanocrystalline magnetic core annealed under TFA1 decreased along with the increasing magnetic field. As a result, the certain size nanocrystalline magnetic core with low $H_c$ of 0.6 A/m, low core loss (W at 20 kHz) of 1.6 W/kg under flux density of 0.2 T and high $L_s$ of $13.8{\mu}H$ were obtained after TFA1 with the DC intensity of 140 A. The combination of high $L_s$ with excellent magnetic properties promised this nanocrystalline alloy an outstanding economical application in high frequency transformers.

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.

High field HTS insert coils : Status and key technical issue

  • Schwartz, Justin
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.22-22
    • /
    • 2000
  • The discoveries of high temperature superconductors received great attention due to their high critical temperatures. These materials also exhibit extremely high critical magnetic fields and high critical current density at low temperature, high magnetic field. Thus, they are the most promising materials for superconducting magnets above 20 T. In this talk, progress in the development of HTS materials and insert coils at the National High Magnetic Field Laboratory will be reviewed. In 1999, a Bi-2212 stack of double pancakes generated 3 T in a 19 T background field. These results will be reviewed in terms of implications for future systems. Individual double pancakes of Bi-2223 have also been tested and their performance will also be discused. The present goal of a 57 system will be presented and the key technical requirements for larger, higher field systems will be addressed. It will be shown that in addition to increased critical current density, improved mechanical performance (stain resistanced) is necessary for high field systems. Furthemore, improvements in the conductor n-value will improve prospects for operational systems.

  • PDF

An Effect of Magnetic Field on VDT Work (VDT 작업시 자기장이 인체에 미치는 영향에 관한 연구)

  • 박재희;김철중;이남식;김진호
    • Proceedings of the ESK Conference
    • /
    • 1992.10a
    • /
    • pp.77-83
    • /
    • 1992
  • The effect of magnetic field on VDT work has not been clarified yet, but many studies repoerted that magnetic field could cause of the cancers. Many developed countries have set the criteria of magnetic field and produce the VDT which has lower magnetic value. The purpose of this study was to measure the intensity of magnectic field from VDT. For this purpose three experiments were performed. The first was designed to measure the intensity of magnetic field by distances(30,60,90 cm) and directions. The second was to compare the intensities between VDT and Color TV. The last was to evaluate the eye protec- tion glasses. The reults showed that the intensity of magnetic field was lowered in proportion to the distance $r^{3}$and both lateral sides of the VDT marked high values compared to the frontal and back sides. On the same distance (30 cm) color TV marked high value to the VDT. But on the normal work distance (TV: 100 cm, VDT: 30 cm) there was little difference, Eye protection glasses could not protect the magnetic field physically.

  • PDF

Angular distributions of the critical current of ReBCO coated conductors in magnetic field up to 5T

  • Mineev, Nikolay A.;Rudnev, Igor A.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.6-9
    • /
    • 2015
  • For many applications of $ReBa_2Cu_3O_{7-x}$ (ReBCO) tapes it is needed to know the anisotropic properties of the used conductor in a broad range of magnetic field. In this paper we present the results of transport measurements on the SuNAM tape (GdBaCuO) with the rotation of the sample in magnetic fields up to 5 T in liquid nitrogen. The critical current over the magnetic field orientation ($I_c({\theta})$) curves demonstrate the appearance of distinct second peak around c-axis in low fields. This peak almost vanishes in the fields over 3 T. The evolution of the ab-peak form is also presented: the peak consistently reduces its height with the magnetic field going up and in the high fields the shoulders rise, changing the type of the distribution. To describe experimental curves the vortex path model was applied to the angular distributions of the critical current in magnetic field. Good agreements of the experimental data with the analytical expressions were obtained that confirm the vortex path model approach.

Magnetic Field and Electric Field Generated in an HTS Tape of a High Temperature Superconducting Magnet (고온 초전도 마그넷의 선재에서 발생되는 자장과 전계 해석)

  • Kim, Young-Min;Ku, Myung-Hwan;Cha, Guee-Soo;Jeon, Chang-Wan;Paik, Kyoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.753-758
    • /
    • 2011
  • Magnetic field and Electric field of High Temperature Superconducting magnet are very important to analysis of superconducting magnet. The maximum perpendicular magnetic field was applied to the outermost pancake windings. The critical current of all the magnet windings is limited by the critical current of the outermost pancake windings. The E-J relation was used to determine the critical current, and an evolution s trategy was adopted for the optimization of gap length between each pancake windins. The results of calculations show that the critical current and the central magnetic field and uniformity increased by 82.6% and 31.6% and 50.8%, respectively, for a magnet consisting of ten pancake windings. This paper did an analysis the cause of increase the critical current and central magnetic field and uniformity in no gap and optimal gap model.

Investigations on the Induced Magnetic Fields in High Speed Train due to the Current in the High Speed Railroad Catenary Wire (고속철도의 가선전류에 의한 고속열차내의 자기장 유도에 대한 연구)

  • Han, In-Su;Lee, Tae-Hyung;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.36-40
    • /
    • 2010
  • In recent society, the electricity is so essential for the human lives. Lots of modern people take many cultural benefits owing to the development of the power systems, the cell phone, the electrical appliances, and etc. However, the problems related to the electromagnetic field generate as the side effects. Examples are the fault in the electric machinery due to the electromagnetic coupling, the fault in the communication devices due to the electromagnetic field around the power line equipments, and the effect upon the human beings due to the electromagnetic field, and etc. In this paper, we induce the vector equation about the magnetic field based on Biot-Savart law. We calculate the magnetic field at the surface of the high speed train with this induced equation and the current in the high speed railroad catenary wire. Finally, we calculate the magnetic field in the high speed train considering the material property like the permeability, the conductivity, and so on.

  • PDF