• Title/Summary/Keyword: High Quality Factor

Search Result 1,911, Processing Time 0.03 seconds

Implementation of Z-Factor Statistics for Performance Evaluation of Quality Innovation in the High Throughput Process (High Throughput 프로세스에서 품질혁신의 성능평가를 위한 Z-Factor의 적용방안)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.293-301
    • /
    • 2013
  • The purpose of this study is to introduce the limit of previously used six sigma quality process evaluation metrics, $Z_{st}$ and $P_{pk}$, and a solution to overcome this drawback by using a metric based on performance evaluation of Z-factor quality innovation. Case analysis on projects from national six sigma contest from 2011 to 2012 is performed and literature review on new drug development HTS (High Throughput Screening) is used to propose innovative performance evaluation metrics. This research shows that experimental study on six sigma evaluation metric, $Z_{st}$ and $P_{pk}$, have no significance difference between industrial type (Manufacturing, Semi-Public Institute, Public Institute) and CTQ type (Product Technology Type CTQ, Process Technology Type CTQ). Following discovery characterize this quality improvement as fixed target type project. As newly developed moving target type of quality innovation performance metric Z-Factor is used for evaluating experimental study, hypothetical analysis suggests that $Z_{st}$ and $P_{pk}$ share different relationship or even show reciprocal relationship. Constraints of the study are relatively small sample size of only 37 projects from past 2 years and conflict on having interview and communication with six sigma quality practitioner for qualitative experimental study. Both moving target type six sigma innovation project and fixed target type improvement project or quality circle enables efficient ways for a better understanding and quality practitioner use by applying quality innovation performance metric. Downside of fixed target type quality performance evaluation metric, $Z_{st}$ and $P_{pk}$, is presented through experimental study. In contrast, advantage of this study is that high throughput requiring product technology, process technology and quantum leap typed innovation effect is evaluated based on precision and accuracy and Z-Factor that enables relative comparison between enterprises is proposed and implemented.

Wafer-Level Packaged MEMS Resonators with a Highly Vacuum-Sensitive Quality Factor

  • Kang, Seok Jin;Moon, Young Soon;Son, Won Ho;Choi, Sie Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.632-639
    • /
    • 2014
  • Mechanical stress and the vacuum level are the two main factors dominating the quality factor of a resonator operated in the vacuum range 1 mTorr to 10 Torr. This means that if the quality factor of a resonator is very insensitive to the mechanical stress in the vacuum range, it is sensitive to mainly the ambient vacuum level. In this paper, a wafer-level packaged MEMS resonator with a highly vacuum-sensitive quality factor is presented. The proposed device is characterized by a package with out-of-plane symmetry and a suspending structure with only a single anchor. Out-of-plane symmetry helps prevent deformation of the packaged device due to thermal mismatch, and a single-clamped structure facilitates constraint-free displacement. As a result, the proposed device is very insensitive to mechanical stress and is sensitive to mainly the ambient vacuum level. The average quality factors of the devices packaged under pressures of 50, 100, and 200 mTorr were 4987, 3415, and 2127, respectively. The results demonstrated the high controllability of the quality factor by vacuum adjustment. The mechanical robustness of the quality factor was confirmed by comparing the quality factors before and after high-temperature storage. Furthermore, through more than 50 days of monitoring, the stability of the quality factor was also certified.

Evaluation of Water Quality using Principal Component Analysis in the Nakdong Rivev Estuary (주성분 분석법을 이용한 낙동강 하구 해역의 수질 평가)

  • Sin, Seong-Gyo;Park, Cheong-Gil;Song, Gyo-Uk
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.171-176
    • /
    • 1998
  • This study was conducted to evaluate water quality utilizing principal component analysis in the Nakdong River Estuary. From the results of analysis, water quality in the Nakdong River Estuary could be explained up to 65.3 Percente by three factors which were Included In river loadlnwastes from the Nakdong River and rainfalls : 39.1%1, sediment resuspension(13.7BS) and metabolism(12.5%). In the eastern part of estuary In flowing the Nakdong River, river loading factor score(factor 1 Pas higher than that In western part. Sediment resuspension factor score(factor 2) was high in shallow water, while metabolism factor score(factor 3) was high in deeper water. For seasonal variations of factors score, factor 1 was h19h- 1y related to rainfall season.

  • PDF

An experimental study on the fragility factor of high strength concrete (고강도 콘크리트의 취도계수에 관한 실험적 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.148-149
    • /
    • 2014
  • In modern society, population overcrowding and concentration of facilities are happened because of the concentration on to city. So this phenomenon demands improvement of material's performance, technical development of structure analysis and design and improvement of constructing ability .High strength concrete has some merits. High strengthening makes the cross section reduced, and that cause decrease of structure weight. And using high durable and superplasticizer promote liquidity, thus high quality concrete can be produced. Because of these advantages, this study is for showing validity of using it by compression/tensile strength experiment. As this experiment's result, when concrete become stronger, interface intensity coefficient between cement and aggregate is different and they don't adhere to each other. So there is brittle failure. Fragility factor also steadily increase with strong concrete, it tells high strength concrete has problem. Therefore the sources used in high strength concrete like cement and aggregate must have great quality. So the source's performance must be supervised well because their quality decides performance criteria.

  • PDF

Research about Competitive Power High Position of Food-Service Industry - Laying Stress on Eating Out Company Interior Factor - (외식기업의 경쟁력 강화 요인에 관한 연구 - 외식기업 내부요인을 중심으로 -)

  • 유택용;박면애
    • Culinary science and hospitality research
    • /
    • v.10 no.3
    • /
    • pp.83-96
    • /
    • 2004
  • According to construction of global administration environment, all over the world was ended up in infinite competition period. Because eating out company also competes with another company, it must enjoy competitive power high position to secure high position continuously, classified by formation constituent's individuation and two aspects of organic special quality by the factor. Individuation classified by formation constituent's business ability, personal relations, age factors of Information Technology, and organic special quality classifies by factor of formation culture and result that analyze eating out company's business condition competitive power reinforcement effect factor is same as following. First, was construed by company culture, personal relations, business ability period of ten days with family Restaurant, and Information Technology showed that do not influence. Competitive power reinforcement effect factor with special restaurant was construed by company culture, personal relations, business ability period of ten days, and fast food company culture and Information Technology factor with hotel restaurant company culture by competitive power reinforcement effect factor construe.

  • PDF

A Study for Solenoid-Type RF Chip Inductors (솔레노이드 형태의 RF 칩 인덕터에 대한 연구)

  • 김재욱;윤의중;정여창;홍철호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.10
    • /
    • pp.840-846
    • /
    • 2000
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss Al$_2$O$_3$core material were investigated. The size of the chip inductors fabricated in this work were 15$\times$10$\times$0.7㎣, 2.1$\times$1.5$\times$10㎣, and 2.4$\times$2.0$\times$1.4㎣ and copper (Cu) wire with 40 ㎛ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured suing an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 33 to 100nH and exhibit the self-resonant frequency (SRF) of .26 to 1.1 GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 60 to 80 in the frequency range of 300 MHz to 1.1 GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully. It is suggested that the thin film-type inductor is necessary to fabricate the smaller size inductors at the expence of inductance and quality factor values.

  • PDF

The Evaluation of Water Quality in Coastal Sea of Incheon Using a Multivariate Analysis (다변량 해석기법을 이용한 인천연안해역의 수질평가)

  • Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1017-1025
    • /
    • 2006
  • This study was conducted to evaluate characteristic of water duality in coastal sea of Incheon using a multivariate analysis. The analysis data in coastal sea of Incheon was aquired by the NFRDI data which was surveyed from March 1997 to November 2003. Eleven water quality parameters were determined on each survey The results were summarized as follow : Water quality in Incheon coastal sea could be explained up to 64.62% by three factors which were included in loading of fresh water and nutrients by the land(36.98%), seasonal variation(16.19%), and internal metabolism (11.24%). The results of time series analysis by factor score, in case of factor 1, station 1 influenced by Han river was shown to high factor score and station 3 located by outer sea was shown to low factor score. In case of factor 2, station 1 was appeared to high variation and station 3 was appeared to low variation. The result of cluster analysis by station was classified into three group that has different water quality characteristics. Especially, station 1 which affected by Han river and station 4 which affected by sewage treatment plant was appeared to considerable water quality characteristics against other station. In yearly cluster analysis, three group was classified and water quality in 2003 years due to high precipitation was different to another year. It could be suggested from these results that it is important to control discharge of fresh water by Han rivet and sewage treatment plant for water quality management of coastal sea of Incheon.

Factor Analyses for Water Quality Indicators of Streams, Ground Water, and Reservoir in Agricultural Small Catchments of the Han River Basin

  • Park, C-S;Joo, J-H;Jung, Y-S;Yang, J-E
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.5
    • /
    • pp.382-393
    • /
    • 2000
  • The principal indicators contributing to water qualities was screened by factor analyses, based on the monitored chemical parameters of water quality for various water resources from 1995 to 1999 in the small agricultural catchments of the Han River Basin. Water samples of streams, groundwaters, and reservoirs were taken four times a year from upper (Daegwanryong), middle (Dunnae and Chunchon) and lower (Guri) reaches of Han River Basin. In these areas, the respective type of farming practiced was alpine agriculture and livestocks raising, typical upland and paddy cultivation, and intensive cropping in the plastic film house. Water quality was monitored for twenty-one water quality parameters, including pH, EC, SS, T-N, T-P, COD, cations, anions, and heavy metals. pH, EC and COD of the stream waters were suitable for the Korea irrigation water quality guidelines. However, T-N and T-P concentrations of water samples in four catchments far exceeded the irrigation water guideline. Concentrations of canons and heavy metals in Wangsuk stream in Guri area were higher than those in streams in other areas. Factor analysis revealed that significant correlation was observed for 81 pairs out of 231 water quality indicators of stream water among the $21\;{\times}\;21$ cross correlation matrix of stream water quality indicators. The first factor accounted for 27.01% of the total variation in stream water quality indicators, and high positive factor loadings were shown on EC, K, Na, $NH_4\;^+-N$, $PO_4\;^{3-}$, $SO_4\;^{2-}$, and COD. Fifty-three water quality indicator pairs were significant out of 190 ground water quality parameters. The first factor accounted for 28.54% of the total variation in ground water quality indicators, and high loadings were revealed on EC, Ca, Mg, K, Na, $NH_4\;^+-N$, and $SO_4$. Twenty-nine pairs of reservoir water quality indicators were significant out of 66 pairs. The first factor accounted for 37.06% of the total variation in reservoir water quality indicators, and high loadings were shown on EC, Mg, K, Na, SS, T-P, Cl, and COD. These results demonstrate that EC was the first factor contributing to water quality.

  • PDF

A Study on the Measurement Methodology of Characteristics of the Vibratory Micro Gyroscope Using the Quality factor and the Resonant Displacement (Quality factor 와 공진시 변위 측정을 이용한 진동형 자이로스코프의 특성 평가에 관한 연구)

  • Jeon, Seung-Hoon;Lee, June-Young;Jung, Hyoung-Kyoon;Chang, Hyun-Kee;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2090-2092
    • /
    • 2004
  • In this paper, the new measurement methodology of characteristics of the vibratory micro gyroscope using Quality factor and the resonant displacement was proposed. Because the Quality factor has a large error under the high Quality factor condition, it is difficult to analyze the characteristics of the vacuum packaged vibratory micro gyroscopes with the Quality factor. We analyzed mechanical characteristics of gyroscope with the value of Quality factor. We described measurement errors of mechanical characteristics of micro gyroscopes. The measured value of Quality factor is 47532 and error range of Quality factor is from -29.8 % to 73.9 %. The value of resonant displacement is 3.4${\mu}m$ and the measurement error is 2.9 %. From the result of Quality factor degradation and resonant displacement degradation, 1698 days and 1503 days were estimated as Time To Failure (TTF), respectively. The range of estimation error of Quality factor degradation and resonant displacement degradation is calculated from 1246 days to 1832 days and from 1456 days to 1537 days, respectively. We can analyze the characteristics of the vibratory gyroscope using the quality factor when the Quality factor is smaller than 10,000. Also we can analyze that using the resonant displacement when the Quality factor is larger than 10,000.

  • PDF

A Study on Resonance Properties of a Terahertz Asymmetric Split-Loop Resonator Type Metamaterial for High Quality Factor (테라헤르츠 비대칭 분리고리공진기 메타물질의 높은 품질인자를 위한 공진 특성에 관한 연구)

  • Park, Dae-Jun;Ryu, Han-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.663-669
    • /
    • 2016
  • A terahertz asymmetric split-loop resonator (ASLR) was analyzed for use in high-sensitivity sensing applications. Its structural asymmetricity induces an asymmetric Fano resonance which has a high quality factor compared to the symmetric eigen-resonance. The variations of the resonant frequency, transmission coefficient, and quality factor of the ASLR in the eigen and Fano resonances are analyzed as a function of its structural asymmetricity. Also, the surface current densities on the ASLR in both resonances are calculated to analyze the main cause of the variations of its transmission characteristics. The surface current of the ASLR in the eigen resonance shows a dipole resonance, which increases the radiation loss and reduces the quality factor. On the other hand, the surface current of the ASLR in the Fano resonance shows a trapped or quadrupole mode which has a low radiation loss. Therefore, the ASLR operated in the Fano resonance has a high quality factor. Terahertz, high-performance filters and high sensitivity sensors can be developed based on our analysis results of the ASLR having a high quality factor. These high-performance devices based on terahertz metamaterials could increase the adoption of terahertz industrial applications.