• 제목/요약/키워드: High Speed Imaging system

검색결과 129건 처리시간 0.03초

적외선 체열촬영시스템을 위한 고속 광주사기의 구현 (Realization of a High Speed Optic Scanner for Infrared Thermal Imaging)

  • 이수열
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.43-48
    • /
    • 1995
  • A high speed optic scanner capable of 16 frames/sec imaging has been developed for the realization of the infrared thermal Imaging system with a single element infrared sensor. The high speed optic scanner is composed of a rotating polygon mirror for horizontal scanning, a flat mirror mounted on a galvanometer for vertical scanning, and a spherical mirror. It has been experimentally found that the optic scanner is capable of 16 framesllsec imaging with the frame matrix size of 256 x 64.

  • PDF

고속 DSP를 이용한 실시간 자기공명영상시스템 제어 (Real-time Interactive Control of Magnetic Resonance Imaging System Using High-speed Digital Signal Processors)

  • 안창범;김휴정;이흥규
    • 전자공학회논문지SC
    • /
    • 제40권5호
    • /
    • pp.341-349
    • /
    • 2003
  • 고속 디지털신호처리기를 사용한 자기공명영상 실시간 대화형 제어기(스펙트로미터)를 개발하였다. 개발린 제어기는 rf 파형과 경사자계 파형을 만들고, 신호 측정을 위한 다중 측정기를 제어한다. TMS320C6701과 간은 높은 계산 능력을 가진 디지털신호처리기를 사용함으로써 복잡한 경사자계파형의 실시간 계산 및 출력이 가능해졌다. 또한 회전 행렬을 실시간으로 계산함으로써 심장과 같이 움직임이 큰 장기의 실시간 영상에서 얻고자하는 평면을 대화식으로 조절이 가능해졌다. 개발된 스펙트로미터를 1.5 테슬라 전신자기공명 영상시스템에 성공적으로 적용하였다. 개발된 스펙트로미터를 고속스핀에코나 echo planar imaging(EPI) 등과 같은 초고속자기공명영상에 적용하여 성능을 검증하였다. 이것은 이들 초고속 자기공명영상기법들이 측정 시간을 단축해주는 대신에 스펙트로미터의 송신부와 수신부 또는 경사자계부간의 동기나 위상에 에러가 있을 경우 문제점을 크게 부각시켜 시스템의 성능 평가에 적합하기 때문이다.

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

A High-Speed Single Crystal Silicon AFM Probe Integrated with PZT Actuator for High-Speed Imaging Applications

  • Cho, Il-Joo;Yun, Kwang-Seok;Nam, Hyo-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.119-122
    • /
    • 2011
  • A new high speed AFM probe has been proposed and fabricated. The probe is integrated with PZT actuated cantilever realized in bulk silicon wafer using heavily boron doped silicon as an etch stop layer. The cantilever thickness can be accurately controlled by the boron diffusion process. Thick SCS cantilever and integrated PZT actuator make it possible to be operated at high speed for fast imaging. The resonant frequency of the fabricated probe is 92.9 kHz and the maximum deflection is 5.3 ${\mu}m$ at 3 V. The fabricated probe successfully measured the surface of standard sample in an AFM system at the scan speed of 600${\mu}m$/sec.

고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징 (Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo)

  • 조한샘;장선주;오왕열
    • 한국광학회지
    • /
    • 제25권2호
    • /
    • pp.67-71
    • /
    • 2014
  • 혈관 내 OCT (optical coherence tomography) 는 혈관 벽 내부의 3차원적 미세구조를 영상화할 수 있어서 임상에서 각광을 받고 있다. 하지만 아직도 충분하지 못한 이미징 속도, 특히 내시경 프로브의 이미징 광 스캐닝 속도의 부족으로 혈관 길이 방향의 이미징 간격이 실제 시스템의 광학적 해상도보다 5배 이상 커서 혈관 종방향으로의 고해상도 이미징이 얻어지지 못하고 있는 상황이다. 본 논문에서는 초당 350장의 혈관 벽 단층 영상을 제공하는 고속 혈관 내 OCT 시스템을 기술한다. 본 시스템과 내시경 장치를 이용하여 47 mm 길이의 살아있는 토끼 대동맥을 3.7초만에 34 micron의 혈관 종방향 간격으로 얻는데 성공하였다. 34 micron의 종방향 간격은 실제 내시경의 그 방향 광학적 해상도와 비슷한 정도로서 3차원 모든 방향으로의 고해상도 이미징을 구현하였음을 보여준다. 얻어진 이미징 데이터의 3차원 영상 구현을 통해 혈관의 미세구조 및 이미징 전 삽입된 스텐트의 자세한 구조를 보였다.

Pathological Vibratory patterns of the Vocal Folds Observed by the High Speed Digital Imaging System

  • Niimi, Seiji
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 1998년도 제10회 학술대회 심포지움
    • /
    • pp.208-209
    • /
    • 1998
  • It is generally known that many cases of pathological rough voice are characterized not by simple random perturbations but by quasi-periodic perturbations in the speech wave. However, there are few studies on the characteristics of perturbations in vocal fold vibrations associated with this type of voice. We have been conducting studies of pathological vocal fold vibration using a high-speed digital image recording system developed by our institute, Compared to the ordinary high-speed-motion picture system, the present system is compact and simple to operate and thus, it suited for pathological data collection. (omitted)

  • PDF

Spaceborne High Speed Data Link Design for Multi-Mode SAR Image Data Transmission

  • Kwag, Young-Kil
    • Journal of electromagnetic engineering and science
    • /
    • 제2권1호
    • /
    • pp.39-44
    • /
    • 2002
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution because of the strict requirement far the real-time data transmission of the massive SAR data in a limited time of mission. In this paper, based on the data lint model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath.

반도체 Bump 검사를 위한 백색광 주사 간섭계의 고속화 (A High-Speed White-Light Scanning Interferometer for Bump Inspection of Semiconductor Manufacture)

  • 고국원;심재환;김민영
    • 한국정밀공학회지
    • /
    • 제30권7호
    • /
    • pp.702-708
    • /
    • 2013
  • The white-light scanning interferometer (WSI) is an effective optical measurement system for high-precision industries (e.g., flat-panel display and electronics packaging manufacturers) and semiconductor manufacturing industries. Its major disadvantages include a slow image-capturing speed for interferogram acquisition and a high computational cost for peak-detection on the acquired interferogram. Here, a WSI system is proposed for the semiconductor inspection process. The new imaging acquisition technique uses an 'on-the-fly' imaging system. During the vertical scanning motion of the WSI, interference fringe images are sequentially acquired at a series of pre-defined lens positions, without conventional stepwise motions. To reduce the calculation time, a parallel computing method is used to link multiple personal computers (PCs). Experiments were performed to evaluate the proposed high-speed WSI system.

3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상 (High-resolution Spiral-scan Imaging at 3 Tesla MRI)

  • 김판기;임종우;강승원;조상흠;전수열;임헌진;박호종;오승준;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.108-116
    • /
    • 2006
  • 목적 : 3.0 Tesla 고 자장에서 고 해상도 나선주사영상을 수행하였다. 나선주사영상은 초고속 영상기법의 하나로서, Echo Planar Imaging(EPI)에 비하여 eddy current 가 작게 발생하고, 경사자계 파형의 기울기가 완만하여 상대적으로 낮은 slew rate 를 가진 경사자계시스템으로 구현이 가능한 장점이 있다. 또한 고 자장 영상에서 고속스핀에코(Fast Spin Echo: FSE) 등의 rf 에코 기반의 고속영상방법에서 심각하게 대두되는 SAR 문제가 근원적으로 발생하지 않는 장점이 있어 고 자장에서의 초고속영상방법으로 주목을 받고 있다. 본 연구에서는 3.0 Tesla 에서 나선주사방식으로 고 해상도 영상을 얻어 고 자장 MRI에서 나선주사영상기법의 다양한 응용 가능성을 살펴보고자 한다. 대상 및 방법 : 3 Tesla 전신 자기 공명 영상 시스템에서 다양한 해상도의 나선주사영상 방법을 개발하였다. 고차(higher-order) shimming 을 통하여 영상의 화질을 개선하였고, 해상도에 맞게 interleaves 수를 조절하였다. 스핀에코 와 gradient에코 기반 나선주사영상방법을 구현하였고, 에코 time 과 repetition time, rf 회전 각도를 조절하여 영상의 대조도(contrast)와 신호대잡음비를 조절하였다. 결과 : 3 Tesla 전신 자기 공명 영상 시스템에서 나선 주사 방법을 이용하여 다양한 해상도의 영상을 얻었다. 고 자장에서 주 자장의 불균일도(inhomogeneity) 의 절대 크기가 커지기 때문에 이를 줄이기 위한 shimming 이 더욱 중요해진다. 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구하여 spherical harmonics 분석으로 고차 shimming을 하였다. 팬텀과 in-vivo 두부 영상에서 single shot 나선주사 영상으로 $100{\times}100$ 정도의 영상과 6-12 정도의 interleaves 를 적용하여 $256{\times}256$ 의 고 해상도 영상을 얻을 수 있었다. 결론 : 신호대잡음비의 향상과 스펙트럼의 분리, 뇌기능영상에서 BOLD 효과 향상 등으로 고자장 영상에 대한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다.

  • PDF