• Title/Summary/Keyword: Higher order harmonics

Search Result 62, Processing Time 0.034 seconds

Measurement of Saturation Magnetostriction by the Second-order Higher Harmonics of ac Perturbing Magnetic Field (교류 섭동 자기장의 제 2차 고조파를 이용한 포화자기변헝 측정)

  • Cha, S.Y.;Kim, J.K.;Ryu, K.S.;Cho, Y.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.72-75
    • /
    • 2005
  • The profiles of the second-order higher harmonics during B-H hysteresis loop have been measured as functions of the tensile stress in grain-oriented $3.2{\%}$ Si steels. The observed harmonics profiles have been analyzed in terms of the nonlinear, asymmetric magnetization which reflects the domain reorientation under the field. The field interval of the second-order higher harmonics is related to the nucleation and annihilation fields and a measurement method for the magnetostriction is proposed using the harmonics profiles under tensile stress.

A Study on the Characteristic of Capacitor by Asymmetrical Voltage Unbalance (비대칭 전압 불평형에 의한 커패시터 동작 특성)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • As the increasing of Non-linear load, we have been growing interest for the harmonics. Harmonics has been focused on the current component rather than voltages. Voltage harmonics can be mainly generated at the PCC with non-linear load and act on voltage unbalance. Voltage harmonics can be enlarged at the capacitor with low impedance as frequency increases. Capacitor is basically used for the power-factor compensation and sometimes as the passive filter. Small voltage of low-order acts on quite a few at the capacitor by the current increase. Capacitor has easily fall under by harmonic components. In this paper, we measured the magnitude and phase angle of asymmetrical voltage with harmonics components at the PCC and calculated with the same condition. we concluded that voltage harmonics of higher order increase each current component but have a little effect on capacitor rating.

An Elimination Method of Harmonics in AC to DC Converter (AC/DC 컨버터의 고조파 제거 방법)

  • 오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.767-775
    • /
    • 2003
  • This paper considers the method of elimination harmonics in AC/DC converters, There are few practical methods to reduce the harmonics in AC/DC converters, particularly in filter design and control strategy. In this paper, a harmonic elimination methods are proposed, which includes hybrid PWM control strategy. These methods achieve precise output control along with the optimum performance simultaneously. The control method in this paper is developed to eliminate a fixed number of harmonics in AC to DC converter. The higher order harmonics can be easily eliminated by using filter proposed in this paper. The validity of these methods is confirmed experimentally.

Harmonics Analysis of Magnetostriction in 3% SiFe

  • Kim, C.G.;Ahn, S.J.;Jeong, M.H.;Kim, H.C.;Cha, S.Y.;Chang, S.K.
    • Journal of Magnetics
    • /
    • v.3 no.4
    • /
    • pp.120-122
    • /
    • 1998
  • The higher order harmonic components of magnetostriction during ac magnetization in 3% SiFe are measured as a function of the magnetizing angle respect to [001] axis using a constructed laser interferometry. The magnetostriction with magnetizing angle from [001] axis agrees ith the calculation based on domain reorientation. The relative amplitudes of odd and even harmonics respectively for magnetic induction and magnetostriction decrease with the order of harmonics, accompanying the contraction of the amplitudes. The contraction of harmonics order of magnetostriction harmonics is shown to be the even number times of that of magnetic induction.

  • PDF

Higher Order Spectra and Their Application to Mechanical Systems(II) -Analysis on the Interactions of Harmonics in Exhaust Pipe of Engines- (고차스펙트럼과 기계적 시스템의 응용연구(2)-기관 배기관내의 조화파 상호작용 해석-)

  • 이준서;차경옥
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.4
    • /
    • pp.85-92
    • /
    • 2000
  • The pulsating pressure waves are composed of fundamental frequency and higher order harmonics in exhaust pipe of engines. The nonlinearity in exhaust pipe is caused by their interactions. The error which is between prediction and measurement is induced by the nonlinearity. We can not explain this phenomenon using linear acoustic theory which is existing theory. So power spectrum which was used in linear theory is not useful. Bispectrum and bicoherence functions which are a higher order spectrum are applicable to explain this phenomenon. This paper proposes a nonlinear effect of pulsating pressure waves. The phenomenon proposed here is identified by using of higher order spectrum density functions.

  • PDF

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Evaluation of Deterioration of Concrete due to High Temperature through Harmonics (고조파 평가를 통한 콘크리트의 고온 열화 평가)

  • Hwang, Eui-Chul;Kim, Guy-Yong;Son, Min-Jae;Pyeon, Su-Jeong;Sasui, Sasui;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.146-147
    • /
    • 2021
  • In this study, the deterioration of concrete subjected to high temperature was evaluated using harmonics. When concrete is exposed to high temperatures, its mechanical properties deteriorate. In order to evaluate this deterioration, a method of analyzing the waveform of elastic waves was applied. As the heating temperature increased, the fundamental wave of the 50 kHz elastic wave passing through the concrete decreased. In addition, harmonics were generated at each temperature, and the higher the heating temperature, the greater the ratio of harmonics. The higher the compressive strength, the greater the amplitude of the fundamental wave, and this phenomenon is thought to be due to the internal structure of concrete.

  • PDF

Effect of Harmonics on Residual Current Protective Devices (고조파가 누전차단기에 미치는 영향)

  • Jeon, Jeong-Chay;Lee, Sang-Ick;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.84-89
    • /
    • 2006
  • Tripping of residual current protective devices(RCPDs) caused by harmonics has been continuously reported, but no literature is available on the behavior of RCPDs caused by harmonics. This paper, in order to find out the effects of harmonics on RCPDs, investigated the present condition on malfunction of RCPDs and measured harmonics at buildings where nuisance tripping of RCPDs was often occurred. Also, the operational characteristics of RCPDs were tested by the harmonics synthesizer that can generate distorted waveform. Results of experiment detected that there was minimum tripping current of RCPDs when third harmonic added to the fundamental frequency. And it was found that the leakage current to cause tripping of RCPDs increased with more higher order harmonics added to the fundamental frequency.

A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters (단상 계통연계 인버터를 위한 새로운 고조파 보상법)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

Investigation on Flashover Development Mechanism of Polymeric Insulators by Time Frequency Analysis

  • Muniraj, C.;Krishnamoorthi, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1503-1511
    • /
    • 2013
  • This paper deals with the analysis of leakage current characteristics of silicone rubber insulator in order to develop a new condition monitoring tool to identify the flashover of outdoor insulators. In this work, laboratory based pollution performance tests are carried out on silicone rubber insulator under ac voltage at different pollution levels and relative humidity conditions with sodium chloride (NaCl) as a contaminant. Min-Norm spectral analysis is adopted to calculate the higher order harmonics and Signal Noise Ratio (SNR). Choi-Williams Distribution (CWD) function is employed to understand the time frequency characteristics of the leakage current signal. Reported results on silicone rubber insulators show that the flashover development process of outdoor polymer insulators could be identified from the higher order harmonics and signal noise ratio values of leakage current signals.